Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual
Have a look at the manual Panasonic Cs E719k Cs E919 Kcs E1219k Repair Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
UnitCS-E1219KCU-E1219K Capillary TubeLengthmm605 Flow Ratel/min—15.7 Inner Diametermm—1.7 Air FilterMaterial StyleP.P. Honeycomb— Capacity ControlCapillary Tube Compressor CapacitorµF, VAC—30 µF, 400VAC Fan Motor CapacitorµF, VAC1.5 µF, 400VAC2.0 µF, 450VAC Note: • Specifica tions are subject to change without notice for further improvement. 11 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
4 Dimensions 12 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
13 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
5 Refrigeration Cycle Diagram 14 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
6 Block Diagram 15 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
7 Wiring Diagram 16 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Cooling in operation according to Remote Control setting. Time DelaySafety Control (3 minutes) 7 minutes TimeSave Control Starting Current Control Anti-Freezing Control • If the temperature of the indoor heat exchan ger falls continuously below 2°C for 4 minutes or more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan speed setting remains the same. • Compressor will restart again when the indoor heat exchanger temperature rises to 10°C (Recovery). 3 minutes waiting of Time Delay Safety Control is valid for Cooling Operation. Compressor Reverse Rotation Protection Control 8 Operation Details 8.1. Cooling Mode Operation • W hen the compressor is stopped by Remote Control, it restarts after 3 minutes when the Remote Control is turned ON. • W hen the setting temperature is reached during cooling operation, the compressor stops and it will not start for 3 minutes. • The compressor will start automatically if it has stopped for 7 minutes even if the room temperature is between the compressor ON temperature and OFF temperature. • W hen the compressor outdoor fan motor and indoor fan motor are simultaneously started, the indoor fan motor will operate 1.6 second later. • If the compressor is operating continuously for 5 minutes or longer and thetemperature differen ce between intake air and indoor heat exchan ger is 2.5°C or less for 2 minutes, compressor will stop and restart automatically. (Time Delay Safety Control is valid) T = Intake air temperature - Indoor heat exchanger temperature This is to protect reverse rotation of the compressor when there is a instantaneous power failure. 17 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Automatic Fan Speed Mode Cooling Operation Time Diagram WhenAutomatic Fan Speed is selected at Remote Control during cooling operation. • Fan speed rotates in the range of Hi to Me. 18 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Quiet Operation Control (For Cooling Mode or cooling region of Soft Dry Mode) • Purpose of this operation is to provide quite cooling operation compare to normal operation. • W hen the Quiet Mode is set at the remote control, Quiet Mode LED illuminates, the sound level will be automatically decreased 2 dB (Lo), decreased 3 dB (Hi, Me), against the present sound level operation. • Quiet setting of fan speed rpm refer to Indoor Fan Speed Control. • Dew formation become severe at Quiet Lo cool, therefore Quiet Lo cool is operated only 1h 30 min (1h QLo, 30 min QLo + 50). After that, it goes back to Lo cool (However Quiet LED remains on). • Manual Airflow Direction:- − RPM control during Lo cool − RPM control during Hi & Me cool • Auto Airflow Direction:- • Quiet Mode Operation will stop if:- − Quiet mode button is pressed again. − Stopped by ON/OFF switch. − Timer OFF activates. − Powerful mode button is pressed. − W hen change mode to Air Circulation mode. 19 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K
Time DelaySafety Control Starting Current Control Anti-Freezing Control Compressor Reverse Rotation Protection Control Automatic Fan Speed Mode 8.2. Soft Dry Mode Operation • The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote Control, and then Soft Dry operation will start. • During Soft Dry operation, the Indoor Fan will operate at Lo- speed. • The operation will be switched on and off for up to 10 minutes“ON”and 6 minutes“OFF”. Once Soft Dry operation is turned off, it stops for 6 minutes. • Once the compressor stops, it will not start for 3 minutes during Cooling operation. • Same as Starting Current Control for Cooling Mode operation. • Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during compressor stops.) • Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6 minutes waiting is valid during compressor stops.) WhenAutomatic Fan Speed is selected at Remote Control during Soft Dry operation. • Fan speed off and on at Lo- speed. 20 CS-E719K CU-E7 19K / CS-E919K CU-E9 19K / CS-E1219K CU-E1219 K