31 6. Synchronization setting [SYNC] This unit supports the following 5 types of synchronization methods, and one of the following is selected. The order of descriptions below indicates the order of priorities. qMultiplexed vertical drive signal (VD2) wPower supply synchronization (LL) * Synchronization is performed on the basis of the power supply frequency. eComposite color video signal or black burst signal (VBS) rMonochrome composite video signal or composite synchronizing signal (VS)...
Page 32
32 Adjustment of phase in power supply synchronization mode (LL) The adjusting video signal of the camera and the criterial external synchronizing input signal are connected to a 2-input oscilloscope and the phase is adjusted. Note: Movement of the camera or presence of a spike noise in the power line may cause vertical phase change. In such a case, adjust the phase again. Follow the procedure in the next page to adjust the phase. **SYNC** V PHASE COARSE 1(1--16) FINE...
Page 33
33 Step 1 Provide a VBS signal to the external synchro- nizing input connector on the rear side of the camera. →The SYNC setting automatically changes to EXT (VBS). Step 2 Move the cursor to EXT (VBS) and press the setting button. →The SYNC screen appears. Step 3 Connect the video output signal and external synchronizing input signal of the camera to a 2-input oscilloscope, and move the cursor to H PHASE. Step 4 Adjust the oscilloscope to the horizontal rate, and extend the horizontal synchronizing...
Page 34
34 Adjustment of phase in VS genlock mode (VS) The adjusting video signal of the camera and the criterial external synchronizing input signal are connected to a 2-input oscilloscope and the phase is adjusted. Follow the procedure below to adjust the phase. **SYNC** H PHASE ... |...128 - + RET TOP END **CAMERA SETUP** 1/2 CAMERA ID OFF ALC/ELC ALC SHUTTER OFF AGC ON SENS UP OFF SYNC INT WHITE BAL ATW1 MOTION...
Page 35
35 7. White balance setting [WHITE BAL] The white balance adjustment is selectable from the following. ATW1 (default):Activates the automatic color temperature tracking mode. The camera contin- uously measures the color temperature of the light source and automatically adjusts the white balance. Manual fine adjustment is also enabled after automatic white balance set- ting. (page 36) The adjustment of the color temperature ranges from approx. 2 700 K to 6 000 K. If the sit- uation meets one of the...
Page 36
36 8. Motion detector function setting [MOTION DET] The motion detector function is set. Either MODE1 or MODE2 is selected. When MODE1 is selected, the detailed settings such as settings of the detection sensitivity and detection area are required. The detection area can be specified and checked in the demonstration mode. MODE1:Provides an alarm signal when a motion is detected. MODE2:Provides an alarm signal when the camera is covered or the camera direction is changed. OFF (default):Disables the...
Page 37
37 Detection condition Subject size:A moving subject needs to be equal to or larger than 1/48 of the screen at STA- BILIZER OFF. Subject contrast:The contrast ratio between the background and moving subject needs to be equal to or larger than 5 % (at maximum sensitivity). Subject moving speed:The passing time for a subject to move from the end to the other end of the screen needs to be equal to or larger than 0.8 seconds (at 5 % of contrast ratio). A subject moving faster than the description above is...
Page 38
38 **MODE1** LEVEL ... |...128 - + DWELL TIME 2S DISPLAY MODE ALARM OFF MASK SET RET TOP END **CAMERA SETUP** 1/2 CAMERA ID OFF ALC/ELC ALC SHUTTER OFF AGC ON SENS UP OFF SYNC INT WHITE BAL ATW1 MOTION DET OFF DNR HIGH RESOLUTION HIGH BW MODE Advanced settings about motion detector function (MODE1) The description below specifies the sensitivity level and detection area of the motion...
Page 39
39 Step 6 Move the cursor to DISPLAY MODE and press the setting button. →The demonstration mode is implemented, and the blocks on which significant brightness change was detected blink. Step 7 Press the setting button. →The demonstration mode is terminated, and MODE1 screen appears again. Step 8 Move the cursor to LEVEL and use the right or left button to adjust the detection sensitivity level. When the level indicator moves in the + direction, the level becomes higher. When the level indicator moves...
Page 40
40 9. Digital noise reduction function setting [DNR] The digital noise reduction function reduces noise automatically under the condition of low illu- minance. The effect level of the noise reduction function is selectable from the following: LOW:Low level of noise reduction (small residual image) MID:Medium level of noise reduction (medium residual image) HIGH (default):High level of noise reduction (large residual image) 10. Image resolution setting [RESOLUTION] A resolution of camera images is...