Panasonic Camera With Separate Head Aw E300s Operating Instructions
Here you can view all the pages of manual Panasonic Camera With Separate Head Aw E300s Operating Instructions . The Panasonic manuals for Camera are available online for free. You can easily download all the documents as PDF.
Page 31
30 1Picture level adjustment [Picture Level: –50 to +50] This is for adjusting the convergence level of Auto Iris, Auto Gain Up and Auto ND (ELC). (The auto iris is adjusted when a motor-driven lens is used.) 2Light-metering detection ratio adjustment [Light PEAK/AVG: P50 to A50] This enables the ratio of the average level (A) to peak level (P) at which Auto Iris, Auto Gain Up and Auto ND (ELC) are detected to be adjusted. 3Light metering method selection [Light Area:...
Page 32
31 5Auto gain increase selection [Auto Gain Up: OFF, LOW or HIGH] LOW : The function for automatically increasing the gain up to approximately 18 dB is activated, and the light quantity is thereby automatically adjusted. HIGH : The function for automatically increasing the gain up to approximately 30 dB is activated, and if the light quantity is still insufficient, ‘night eye’ (digital gain increase) is added, and the light quantity is thereby automatically adjusted....
Page 33
32 ;White balance selection [White Bal: ATW, AWC A, AWC B, P SET ATW: Automatic operation is performed to ensure that the white balance is attained at all times. AWC A, AWC B: If the white balance is first set and the camera is then used under identical conditions, the need to repeat the white balance setting can be obviated by simply selecting AWC A or AWC B. The colors can be finely adjusted after executing AWC by adjusting the red and blue gain when the camera is used in the...
Page 34
33 CNoise cancellation compensation level selection [Noise Suppress: OFF, LOW or HIGH] This is for reducing the amount of screen noise when HIGH or LOW has been selected as the sharpness (detail)/super-hard level adjustment Bsetting. DClean DNR selection [Clean DNR: OFF, LOW or HIGH] This enables the clean DNR effect to be selected. EFlesh tone sharpness level selection [DTL Flesh Tone: LOW, MID or HIGH] LOW : The roughness of the flesh tones is suppressed. MID : Standard setting HIGH :...
Page 35
34 GElectronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz] This can be set only when “Synchro scan” has been selected as the electronic shutter speed selection Fsetting. The horizontal bar noise can be reduced by adjusting the synchro scan frequency when shooting the screen of a work station, etc. Refer to the table below for the light quantity that should be set at different shutter speeds and synchro scan frequencies. HImage (CCD readout...
Page 36
35 ¢¢ Detail Set1¢¢ Detail (HIGH) H Detail Level H +11 V Detail Level H +12 H Detail Level L +7 V Detail Level L +6 Detail Band 2 Noise Suppress 3 Level Dependent 0% Dark Detail 0 Return Menu Item Settings and Changes (in user mode) OWhen the RCU (RCB) is used, items whose settings are enclosed in the parentheses are set using the switches or controls on the RCU (RCB). OTo return to the initial (factory) settings, refer to page 42. KLMNOPQRST ¢¢ Iris, Shutter, Gain Set¢¢ Picture...
Page 37
36 Menu Item Settings and Changes (in user mode) KPicture level adjustment [Picture Level: –50 to +50] This is for adjusting the AGC/ELC convergence level. LLight-metering detection ratio adjustment [Light PEAK/AVG: P50 to A50] This enables the ratio of the average level (A) to peak level (P) at which AGC/ELC is detected to be adjusted. MLight metering method selection [Light Area: All, center, top cut, bottom cut, R/L cut] This enables the AGC/ELC light-metering method to...
Page 38
37 Menu Item Settings and Changes (in user mode) PElectronic shutter step selection [Step: OFF or 1/100 to 1/10000] This can only be set when “Step” has been selected as the electronic shutter mode selection Osetting. OFF: The electronic shutter is set to OFF. 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000: The electronic shutter is actuated at the respective shutter speed. When the shutter is used at the 1/100 speed in a 50 Hz area, the flicker caused by fluorescent...
Page 39
38 Menu Item Settings and Changes (in user mode) SGain increase adjustment [Gain: AGC HIGH, AGC LOW, 0 dB to 30 dB or N-Eye (night eye)] AGC LOW : The function for automatically increasing the gain up to approximately 18 dB is activated, and the light quantity is thereby automatically adjusted. AGC HIGH : The function for automatically increasing the gain up to approximately 30 dB is activated, and if the light quantity is still insufficient, ‘night eye’ (digital gain increase) is added,...
Page 40
39 Menu Item Settings and Changes (in user mode) WHighlight chroma selection [Highlight Chroma: OFF, LOW or HIGH] When this is set to LOW or HIGH, the dynamic range of the colors is increased to prevent whitening-out in very bright conditions. XPainting adjustment [Painting, R Gain, B Gain, R Pedestal, B Pedestal: –30 to +30] R Gain, B Gain: These enable the white balance after AWC to be finely adjusted when AWC A or AWC B has been selected as the white balance selection...