Page 81

31 (E)
;White balance selection [White Bal: ATW, AWC A, AWC B, P SET]
ATW:
Automatic  operation  is  performed  to  ensure  that  the  white  balance  is  attained  at  all
times.
AWC A, AWC B:
If the white balance is first set and the camera is then used under identical conditions,
the need to repeat the white balance setting can be obviated by simply selecting AWC
A or AWC B.
The colours can be finely adjusted after executing AWC by adjusting the red and blue
gain when the camera is used in the user...

Page 82

32 (E)
ENGLISH
CNoise cancellation compensation level selection 
[Noise Suppress: OFF, LOW or HIGH]
This  is  for  reducing  the  amount  of  screen  noise  when  HIGH  or  LOW  has  been  selected
as the sharpness (detail)/super-hard level adjustment Bsetting.
DClean DNR selection [Clean DNR: OFF, LOW or HIGH]
This enables the clean DNR effect to be selected.
EFlesh tone detail level selection [DTL Flesh Tone: LOW, MID or HIGH]
LOW : The roughness of the flesh tones is suppressed.
MID : Standard...

Page 83

33 (E)
GElectronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz]
This  can  be  set  only  when  “Synchro  scan”  has  been  selected  as  the  electronic  shutter
speed  selection Fsetting.    The  horizontal  bar  noise  can  be  reduced  by  adjusting  the
synchro scan frequency when shooting the screen of a work station, etc.
Refer  to  the  table  below  for  the  light  quantity  that  should  be  set  at  different  shutter
speeds and synchro scan frequencies.
HImage (CCD...

Page 84

34 (E)
ENGLISH
¢¢
Detail Set1¢¢
Detail (HIGH)
H Detail Level H +11
V Detail Level H +12
H Detail Level L +7
V Detail Level L +6
Detail Band 2
Noise Suppress 3
Level Dependent 0%
Dark Detail 0
Return
Menu Item Settings and Changes (in user mode)

OWhen  the  RCU  (RCB)  is  used,  items
whose  settings  are  enclosed  in  the
parentheses  are  set  using  the  switches
or controls on the RCU (RCB).
OTo  return  to  the  initial  (factory)  settings,
refer to page 41.
KLMNOPQRST
¢¢
Iris, Shutter, Gain...

Page 85

35 (E)
Menu Item Settings and Changes (in user mode)
KPicture level adjustment [A. Iris Level: –50 to +50]
This is for adjusting the AGC/ELC convergence level.
LLight-metering detection ratio adjustment [A. Iris PEAK/AVG: P50 to A50]
This  enables  the  ratio  of  the  average  level  (A)  to  peak  level  (P)  at  which  AGC/ELC  is
detected to be adjusted.  
MLight metering method selection 
[A. Iris Area: All, centre, top cut, bottom cut, R/L cut]
This enables the AGC/ELC light-metering method to be...

Page 86

36 (E)
ENGLISH
Menu Item Settings and Changes (in user mode)
PElectronic shutter step selection [Step: OFF or 1/120 to 1/10000]
This  can  only  be  set  when  “Step”  has  been  selected  as  the  electronic  shutter  mode
selection Osetting.
OFF:
The electronic shutter is set to OFF.
1/120, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000:
The electronic shutter is actuated at the respective shutter speed.  

OThe  speed  cannot  be  set  to  1/250,  1/2000,  1/4000  or  1/10000  by  operating  the  RCU...

Page 87

37 (E)
Menu Item Settings and Changes (in user mode)
SGain increase adjustment
[Gain: AGC HIGH, AGC LOW, 0 dB to 30 dB or N-Eye (night eye)]
AGC LOW :The  function  for  automatically  increasing  the  gain  up  to
approximately  18  dB  is  activated,  and  the  light  quantity  is
thereby automatically adjusted.
AGC HIGH :The  function  for  automatically  increasing  the  gain  up  to
approximately  30  dB  is  activated,  and  if  the  light  quantity  is  still
insufficient,  ‘night  eye’  (digital...

Page 88

38 (E)
ENGLISH
Menu Item Settings and Changes (in user mode)
WHighlight chroma selection [Highlight Chroma: OFF, LOW or HIGH]
When  this  is  set  to  LOW  or  HIGH,  the  dynamic  range  of  the  colours  is  increased  to
prevent whitening-out in very bright conditions.
XPainting adjustment [Painting, R Gain, B Gain, R Pedestal, B Pedestal: –30 to +30]
R Gain, B Gain:
These  enable  the  white  balance  after  AWC  to  be  finely  adjusted  when  AWC  A  or
AWC B has been selected as the white balance...

Page 89

39 (E)
Menu Item Settings and Changes (in user mode)
_Horizontal detail level HIGH setting [H Detail Level H: +1 to +63]
Vertical detail level HIGH setting [V Detail Level H: +1 to +31]
Horizontal detail level LOW setting [H Detail Level L: 0 to +62]
Vertical detail level LOW setting [V Detail Level L: 0 to +30]
These  are  for  setting  the  detail  levels  in  the  horizontal  (H)  and  vertical  (V)  directions  at
the detail level selection ^HIGH and LOW settings.
The  HIGH  setting  must  be  higher...

Page 90

40 (E)
ENGLISH
Menu Item Settings and Changes (in user mode)
hColour matrix compensation level adjustment 
[Matrix (R-G), (R-B), (G-R), (G-B), (B-R), (B-G): –31 to +31]
These are for adjusting the colour matrix compensation.
(R-G) : The colours between red and magenta are toned up or down.
(R-B) : The colours between red and yellow are toned up or down.
(G-R) : The colours between green and cyan are toned up or down.
(G-B) : The yellowish green colour is toned up or down.
(B-R) : The colours between blue...