Have a look at the manual Panasonic Camera With Separate Head Aw E300s Operating Instructions online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 10737 Panasonic manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
30 1Picture level adjustment [Picture Level: –50 to +50] This is for adjusting the convergence level of Auto Iris, Auto Gain Up and Auto ND (ELC). (The auto iris is adjusted when a motor-driven lens is used.) 2Light-metering detection ratio adjustment [Light PEAK/AVG: P50 to A50] This enables the ratio of the average level (A) to peak level (P) at which Auto Iris, Auto Gain Up and Auto ND (ELC) are detected to be adjusted. 3Light metering method selection [Light Area: All, center, top cut, bottom cut, R/L cut] This enables the light-metering method for Auto Iris, Auto Gain Up and Auto ND (ELC) to be selected. All : Light metering over the entire screen area; the light of the whole screen is metered. Center : Light metering with priority given to the center of the screen; about one- third of the screen at the top and bottom and one-third on the left and right sides are cut off. Top cut : Light metering with one-third at the top cut off; about one-third of the screen at the top is cut off. Bottom cut : Light metering with one-third at the bottom cut off; about one-third of the screen at the bottom is cut off. R/L cut : Light metering with one-third on the left and right sides cut off; about one- third of the screen on the left and right sides is cut off. AllCenter Top cut Bottom cut R/L cut 4Auto ND (ELC) selection [Auto ND (ELC): OFF or ON] ON : The light quantity is automatically adjusted by controlling the electronic shutter speed. OFF: The light quantity is not automatically adjusted by the electronic shutter speed. OWhen “Auto ND” is selected as the electronic shutter speed setting Fin the “Other set” sub-menu, this menu item is automatically set to ON; it is set to OFF if a setting other than “Auto ND” is selected for F. OWhen the shutter selector switch is set to “ELC” while the RCU (RCB) is being used, this item is set to ON; it is set to OFF if a setting other than “ELC” is selected for the switch. RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC IRISMAN AUTO1000 S/S ELC 500 100 OFFSHUTTER SCENE21 3 USER SET AUTO/ATWPAINTINGGAIN RCU (RCB) Shutter selector switch Menu Item Settings and Changes (in halogen light mode, fluorescent light mode or outdoor mode)
31 5Auto gain increase selection [Auto Gain Up: OFF, LOW or HIGH] LOW : The function for automatically increasing the gain up to approximately 18 dB is activated, and the light quantity is thereby automatically adjusted. HIGH : The function for automatically increasing the gain up to approximately 30 dB is activated, and if the light quantity is still insufficient, ‘night eye’ (digital gain increase) is added, and the light quantity is thereby automatically adjusted. OFF : The function for automatically increasing the gain is not activated (the gain can still be increased manually). The auto gain increase function may not be activated when the camera alone is used. Similarly, it may not be activated when AUTO has been selected as the RCU’s (RCB) iris switch setting. 6Manual gain increase selection [Manu Gain Up: 0 dB to 30 dB or N-Eye (night eye)] This item can be set only when “OFF” has been selected for the auto gain increase selection 5setting. 0 dB: This setting is the one which is normally used. 1 dB to 30 dB: Use this setting when shooting in dark locations and an adequate video output cannot be obtained even if the lens iris is opened. N-Eye: This increases the sensitivity by adding the digital gain increase to the 30 dB gain increase. Only “0 dB,” “9 dB” or “18 dB” can be set when the RCU (RCB) is used. 7Black level adjustment [Pedestal: -30 to +30] This enables the black level (pedestal) of the luminance (Y) signal to be set. It is used to align the black level of two or more cameras. 8Contrast adjustment [Contrast: LOW, MID or HIGH] This enables the contrast to be set in 3 stages. 9Chroma level adjustment [Chroma Level: –3 to +3] This enables the chroma level to be set in ±3 stages. :Flesh tone adjustment [Flesh Tone: –3 to +3] This enables the flesh tones to be set in ±3 stages. Menu Item Settings and Changes (in halogen light mode, fluorescent light mode or outdoor mode)
32 ;White balance selection [White Bal: ATW, AWC A, AWC B, P SET ATW: Automatic operation is performed to ensure that the white balance is attained at all times. AWC A, AWC B: If the white balance is first set and the camera is then used under identical conditions, the need to repeat the white balance setting can be obviated by simply selecting AWC A or AWC B. The colors can be finely adjusted after executing AWC by adjusting the red and blue gain when the camera is used in the user mode or when RCU (RCB) is used. P SET 3200K: The white balance which was adjusted under 3200K lighting is set. P SET 5600K: The white balance which was adjusted under 5600K lighting is set. When RCU (RCB) is used, P SET 3200K and P SET 5600K cannot be set. Color phase adjustment [SC Coarse: 1, 2, 3 or 4] This enables the color phase during genlock to be coarsely adjusted. ?Color phase fine adjustment [SC Fine: –511 to +511] This enables the color phase during genlock to be finely adjusted. @Color bar setup selection [Color Bar Set: 0.0 IRE or 7.5 IRE] This enables the setup level of the color bars to be selected. ASharpness (detail)/super hard switching [Sharpness/super-hard: sharpness/super-hard] Set to “Super-hard” if the detail enhancement is inadequate even when “Sharpness” has been selected and the sharpness (detail)/super-hard level adjustment Bhas been set to LOW or HIGH. When OFF has been selected as the sharpness (detail)/super-hard level adjustment B setting, the detail enhancement feature will not work for “Sharpness” or “Super-hard.” Menu Item Settings and Changes (in halogen light mode, fluorescent light mode or outdoor mode)
33 CNoise cancellation compensation level selection [Noise Suppress: OFF, LOW or HIGH] This is for reducing the amount of screen noise when HIGH or LOW has been selected as the sharpness (detail)/super-hard level adjustment Bsetting. DClean DNR selection [Clean DNR: OFF, LOW or HIGH] This enables the clean DNR effect to be selected. EFlesh tone sharpness level selection [DTL Flesh Tone: LOW, MID or HIGH] LOW : The roughness of the flesh tones is suppressed. MID : Standard setting HIGH : The detail enhancement of the flesh tones is boosted. FElectronic shutter speed selection [Shutter Speed: OFF, 1/100 to 1/10000, synchro scan or auto ND] OFF: The electronic shutter is set to OFF. 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000: The electronic shutter is actuated at the respective shutter speed. When the shutter is used at the 1/100 speed in a 50 Hz area, the flicker caused by fluorescent lighting is minimized. Synchro scan: The electronic shutter is actuated at the shutter speed set by the electronic shutter synchro scan setting G. Auto ND: The light quantity is automatically adjusted by controlling the electronic shutter. (ELC) OThe speed cannot be set to 1/250, 1/2000, 1/4000 or 1/10000 by operating the RCU (RCB). OWhen the auto ND setting is selected under fluorescent lighting, the flicker may increase. OWhen ON is selected as the auto ND (ELC) selection 4setting on the “Brightness Set” sub-menu, the electronic shutter is automatically set to “Auto ND.” Menu Item Settings and Changes (in halogen light mode, fluorescent light mode or outdoor mode) IRISMAN AUTO1000 S/S ELC 500 120 OFFSHUTTER SCENE21 3 USER SET OFFON +18 +9 0(dB)+6 OFF –6(dB) GAINBAR CAMHIGH LOW OFFRCBDTLAGC RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC AUTO/ATWPAINTINGGAIN RCU (RCB) Detail enhancement selector switch (DTL)BSharpness (detail)/super-hard level adjustment [Level: OFF, LOW or HIGH] This enables the sharpness (detail) level to be adjusted when “Sharpness” has been selected for the sharpness (detail)/super hard switching Asetting. When “Super- hard” has been selected, it enables the super-hard level to be adjusted. When RCU (RCB) is used, adjustment is possible using the detail enhancement selector switch (DTL).
34 GElectronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz] This can be set only when “Synchro scan” has been selected as the electronic shutter speed selection Fsetting. The horizontal bar noise can be reduced by adjusting the synchro scan frequency when shooting the screen of a work station, etc. Refer to the table below for the light quantity that should be set at different shutter speeds and synchro scan frequencies. HImage (CCD readout method) selection [V Resolution: Normal or fine] Normal: Normal image. (Field storage is used as the CCD storage method.) Fine: The vertical resolution is improved. (It is improved by frame storage and the electronic shutter with no accompanying increase in the residual image.) IPC control communication speed selection [Baud Rate: 1200, 2400, 4800 or 9600 bps] This is for selecting the baud rate at which the camera is to be controlled from a computer. JNegative/positive selection [Nega/Posi: Posi or Nega] Posi: Normal images. Nega: Images whose light and dark sections and colors are reversed. Negative images are shown only for composite outputs and Y/C outputs when the option cards are used. Menu Item Settings and Changes (in halogen light mode, fluorescent light mode or outdoor mode) Shutter speedSynchro scan frequencyLight quantity ratio required OFF== 1 1/100 99.68Hz 2 1/250 250.0Hz 4 1/500 492.2Hz 8 1/1000 984.4Hz 16 1/2000 1.969kHz 32 1/4000 3.938kHz 64 1/10000 7.875kHz 160
35 ¢¢ Detail Set1¢¢ Detail (HIGH) H Detail Level H +11 V Detail Level H +12 H Detail Level L +7 V Detail Level L +6 Detail Band 2 Noise Suppress 3 Level Dependent 0% Dark Detail 0 Return Menu Item Settings and Changes (in user mode) OWhen the RCU (RCB) is used, items whose settings are enclosed in the parentheses are set using the switches or controls on the RCU (RCB). OTo return to the initial (factory) settings, refer to page 42. KLMNOPQRST ¢¢ Iris, Shutter, Gain Set¢¢ Picture Level ±0 Light PEAK/AVG 0 Light Area Top cut Auto Iris Adjust OFF Shutter Mode (Step) Step (OFF) Syncro Scan --- Field/Frame Field Gain (0dB) Pedestal (±0) Returndefg ¢¢ Detail Set2¢¢ Chroma Detail 0 DTL Flesh Tone MID Corner Detail OFF Precision Detail OFF Return ¢¢ Color Matrix Set¢¢ Matrix(R-G) ±0 Matrix(R-B) ±0 Matrix(G-R) ±0 Matrix(G-B) ±0 Matrix(B-R) ±0 Matrix(B-G) ±0 Return ijk mnop ¢¢ Other Set¢¢ Gamma 0.45 Knee Point 88% White Clip 110% Flare R 0 Flare G 0 Flare B 0 Black Stretch OFF Clean DNR OFF Baud Rate 9600bps Nega/Posi Posi Return UVWX Y ¢¢ Color Set¢¢ Chroma Level ±0 White Bal (AWC A) Highlight Chroma OFF Painting R Gain (±0) B Gain (±0) R Pedestal (±0) B Pedestal (±0) 2D LPF OFF Return Z[\] ¢¢ G/L. Color Bar Set¢¢ H Phase (±0) SC Coarse (1) SC Fine (±0) Color Bar Set 7.5IRE Return ^ _ `abc l $User mode sub-menu screens h
36 Menu Item Settings and Changes (in user mode) KPicture level adjustment [Picture Level: –50 to +50] This is for adjusting the AGC/ELC convergence level. LLight-metering detection ratio adjustment [Light PEAK/AVG: P50 to A50] This enables the ratio of the average level (A) to peak level (P) at which AGC/ELC is detected to be adjusted. MLight metering method selection [Light Area: All, center, top cut, bottom cut, R/L cut] This enables the AGC/ELC light-metering method to be selected. All : Light metering over the entire screen area; the light of the whole screen is metered. Center : Light metering with priority given to the center of the screen; about one- third of the screen at the top and bottom and one-third on the left and right sides are cut off. Top cut : Light metering area with one-third at the top cut off; about one-third of the screen at the top is cut off. Bottom cut : Light metering area with one-third at the bottom cut off; about one-third of the screen at the bottom is cut off. R/L cut : Light metering area with one-third on the left and right sides cut off; about one-third of the screen on the left and right sides is cut off. NAuto iris fine level adjustment [Auto Iris Adjust: OFF or ON] ON : When the iris switch on the RCU (RCB) is at AUTO, the AGC/ELC convergence level can be finely adjusted using the iris control. OFF: The iris control does not work when the iris switch on the RCU (RCB) is at AUTO. OElectronic shutter mode selection [Shutter Mode: Step, ELC or synchro scan] Step : The electronic shutter is actuated at the shutter speed selected for electronic shutter step selection P. ELC : The light quantity is automatically adjusted by controlling the electronic shutter. Synchro scan: The electronic shutter is actuated at the shutter speed set by the synchro scan setting Q. When “Frame1” is selected as the CCD readout method selection Rsetting, the electronic shutter mode cannot be set. AllCenter Top cut Bottom cut R/L cut RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC IRISMAN AUTO1000 S/S ELC 500 100 OFFSHUTTER SCENE21 3 USER SET AUTO/ATWPAINTINGGAIN RCU (RCB) Iris switchIris control
37 Menu Item Settings and Changes (in user mode) PElectronic shutter step selection [Step: OFF or 1/100 to 1/10000] This can only be set when “Step” has been selected as the electronic shutter mode selection Osetting. OFF: The electronic shutter is set to OFF. 1/100, 1/250, 1/500, 1/1000, 1/2000, 1/4000, 1/10000: The electronic shutter is actuated at the respective shutter speed. When the shutter is used at the 1/100 speed in a 50 Hz area, the flicker caused by fluorescent lighting is minimized. OThe speed cannot be set to 1/250, 1/2000, 1/4000 or 1/10000 by operating the RCU (RCB). OELC may not operate when the camera alone is used. Similarly, it may not work when AUTO has been selected as the RCU (RCB) iris switch setting. OWhen ELC is set under fluorescent lighting, the flicker may increase. QElectronic shutter synchro scan setting [Synchro Scan: 60.34 Hz to 15.75 kHz] This can be set only when “Synchro scan” has been selected as the electronic shutter mode selection Osetting. The horizontal bar noise can be reduced by adjusting the synchro scan frequency when shooting the screen of a work station, etc. Refer to the table below for the light quantity that should be set at different shutter speeds and synchro scan frequencies. RCCD readout method selection [Field/Frame: Field, frame1 or frame2] Field : Field storage is used as the CCD storage method. Frame1 : Frame storage is used, and the vertical resolution is improved as a result. Frame2 : Field storage and the electronic shutter are used, and the vertical resolution is improved with no accompanying increase in the residual image as a result. Shutter speedSynchro scan frequencyLight quantity ratio required OFF== 1 1/100 99.68Hz 2 1/250 250.0Hz 4 1/500 492.2Hz 8 1/1000 984.4Hz 16 1/2000 1.969kHz 32 1/4000 3.938kHz 64 1/10000 7.875kHz 160
38 Menu Item Settings and Changes (in user mode) SGain increase adjustment [Gain: AGC HIGH, AGC LOW, 0 dB to 30 dB or N-Eye (night eye)] AGC LOW : The function for automatically increasing the gain up to approximately 18 dB is activated, and the light quantity is thereby automatically adjusted. AGC HIGH : The function for automatically increasing the gain up to approximately 30 dB is activated, and if the light quantity is still insufficient, ‘night eye’ (digital gain increase) is added, and the light quantity is thereby automatically adjusted. 0 dB : This setting is the one which is normally used. 1 dB to 30 dB : Use this setting when shooting in dark locations and an adequate video output cannot be obtained even if the lens iris is opened. N-Eye : This increases the sensitivity by adding the digital gain increase to the 30 dB gain increase. O“0 dB,” “9 dB,” “18 dB,” “AGC LOW” and “AGC HIGH” can be set by operating the RCU (RCB). OAGC may not operate when the camera alone is used. Similarly, it may not work when AUTO has been selected as the RCU (RCB) iris switch setting. TBlack level adjustment [Pedestal: –30 to +30] This enables the black level (pedestal level) of the luminance (Y) signal to be set. It is used to adjust the black level of two or more cameras. UChroma level adjustment [Chroma Level: –3 to +3] This enables the chroma level to be set in ±3 stages. V White balance selection [White Bal: ATW, AWC A, AWC B, P SET 3200K, P SET 5600K] ATW: Automatic operation is performed to ensure that the white balance is attained at all times. AWC A, AWC B: The color temperature conditions at two locations can be stored in the memory using A and B. If the white balance is first set and the camera is then used under identical conditions, the need to repeat the white balance setting can be obviated by simply selecting AWC A or AWC B. The colors can be finely adjusted after executing AWC by using R Gain and B gain in Painting adjustment Xor by adjusting the R (red) and B (blue) gain controls on the RCU (RCB). P SET 3200K: The white balance which was adjusted under 3200K lighting is set. P SET 5600K: The white balance which was adjusted under 5600K lighting is set. When RCU (RCB) is used, P SET 3200K and P SET 5600K cannot be set.
39 Menu Item Settings and Changes (in user mode) WHighlight chroma selection [Highlight Chroma: OFF, LOW or HIGH] When this is set to LOW or HIGH, the dynamic range of the colors is increased to prevent whitening-out in very bright conditions. XPainting adjustment [Painting, R Gain, B Gain, R Pedestal, B Pedestal: –30 to +30] R Gain, B Gain: These enable the white balance after AWC to be finely adjusted when AWC A or AWC B has been selected as the white balance selection Vsetting. When the RCU (RCB) is to be used for the adjustments, its R (red) and B (blue) gain controls are used. If AWC is executed when using the camera by itself, the settings will return to ±0. R Pedestal, B Pedestal: These enable the black balance after ABC to be finely adjusted. When the RCU (RCB) is to be used for the adjustments, its R (red) and B (blue) pedestal controls are used. If ABC is executed when using the camera by itself, the settings will return to ±0. Y2-dimensional low-pass filter selection [2D LPF: OFF, LOW or HIGH] This is for setting the 2-dimensional low-pass filter which reduces moire and cross color (color blur). ZHorizontal phase adjustment [H Phase: –206 to +49] This enables the horizontal phase during genlock to be adjusted. [Color phase adjustment [SC Coarse: 1, 2, 3 or 4] This enables the color phase during genlock to be coarsely adjusted. \Color phase fine adjustment [SC Fine: –511 to +511] This enables the color phase during genlock to be finely adjusted. ]Color bar setup selection [Color Bar Set: 0.0 IRE or 7.5 IRE] This enables the setup level of the color bars to be selected. ^Detail level selection [Detail: OFF, LOW or HIGH] This enables the detail enhancement amount to be set. The detail is enhanced at the levels set by the horizontal and vertical detail level HIGH/LOW settings _. RB RB PED TOTAL PEDA BATW AWC AUTOHOLD ABC IRISMAN AUTO1000 S/S ELC 500 100 OFFSHUTTER SCENE21 3 USER SET AUTO/ATWPAINTINGGAIN RCU (RCB) R and B gain controls R and B pedestal controls