Page 151

151
Océ TCS400
User manual
Chapter 9 
Manage jobs on the Océ TCS400
Downloaded From ManualsPrinter.com Manuals 

Page 152

152 Océ TCS400 User manual
Introduction to how to manage your jobs
This chapter describes the actions you can perform to manage your jobs. You 
can perform the following actions on the Océ TCS400.
■Delete or stop a job
■Feed originals on the scanner
■Set the Original release mode
■Cut the output
■Clean cut a roll of media
■Change the media type
■Change the default drying time
■Use the fallback mode to adapt the print speed to compensate for failing 
printheads
■Use the Overnight printing feature to print...

Page 153

Manage jobs on the Océ TCS400 153
Delete or stop jobs
Delete or stop an active job on the printer
Introduction
This section describes how to delete or stop an active job on the printer. You 
can delete and stop print jobs from the printer operator panel and from the Océ 
Queue Manager.
How to delete or stop an active print job from the printer operator panel
1
Press the Stop key on the printer operator panel.
The printer stops immediately.
A dialog box on the screen asks the user to resume or delete the...

Page 154

154 Océ TCS400 User manual
How to cancel jobs from the Océ Queue Manager
Attention: You can never undo this action.
1Select the jobs in the print queue, the history queue, or the inbox queue.
2From the Job menu, select Delete, or click the Delete button on the toolbar.
A cross icon indicates the deleted job.
The system does not print the canceled job.
You can select more than one job with the mouse and the shift or control key.
Note:An anonymous user cannot cancel a job from a remote system.
How to...

Page 155

Manage jobs on the Océ TCS400 155
Delete or stop a job on the scanner
Introduction
This section describes how to delete or stop a job on the scanner. The location 
where you delete or stop a job from depends on the type of job and on where 
the job is in the system.
You can delete or stop a copy from the following locations in the system.
■When you scan an original, delete or stop a copy job from the scanner 
operator panel. The scanner stops.
■When a copy job is in a queue on the Océ Queue Manager...

Page 156

156 Océ TCS400 User manual
Handle the originals on the scanner 
Feed the original
Introduction
Use the following methods to feed the original:
Before you begin
Set the Auto feed setting on the System screen.
The Auto feed setting determines the method to feed the original.
■Auto feed is enabled.
When the original is inserted, the original is fed through the scanner. Before 
you feed the original, make sure you first define the correct job settings.
■Auto feed is not enabled. 
When the original is...

Page 157

Manage jobs on the Océ TCS400 157
Original release mode
Introduction
Use the Original release mode on the System screen to define where originals 
are held after the scan is complete.
Before you begin
Use the KO - Scanner - Settings - Original release mode setting in the Océ 
Settings Editor to define the default values.
Define where originals are held after they are scanned
The Original release mode has the following settings:
■Hold
The scanner holds the original at the rear after the scan is complete....

Page 158

158 Océ TCS400 User manual
Thick originals
Introduction
You can adjust the pressure platen on your scanner to the thickness of your 
original.
[30 ] The adj us tment s teps
[30] The adjustment steps
Position Thickness
0 (default position) 2 mm (0.08)
1 4 mm (0.16)
2 6 mm (0.24)
3 8 mm (0.31)
4 10 mm (0.39)
5 12 mm (0.47)
6 14 mm (0.55)
7 16 mm (0.63)
Downloaded From ManualsPrinter.com Manuals 

Page 159

Manage jobs on the Océ TCS400 159
How to adjust the pressure platen to the thickness of your original
1
Open the scanner cover to expose the pressure platen.
2Use one hand to press down on the platen.
3Put two fingers in the recesses in the front of the slider. Adjust the slider to the 
thickness of the original.
[45 ] Put t wo fin gers i n the rec es ses  in  the front  of the s li der
[45] Put two fingers in the recesses in the front of the slider
Use the measurement scale on top of the slider to...

Page 160

160 Océ TCS400 User manual
4Repeat the procedure for the other slider.
Make sure both the sliders are adjusted to same thickness.
5Close the scanner cover.
Note:If the pressure platen is not in the default position for longer than a 
defined time, the error message Unable to adjust the scanner lower the 
pressure platen can appear. If this error message appears, return the pressure 
platen to the default position. Wait until the scanner adjustment is complete, 
then adjust the pressure platen again. (see...