Ensure the best quality output 141 Use the Optimize print quality wizard Introduction The off-line screen of the printer operator panel contains the Optimize print quality wizard that helps you to correct the problems with the output quality. The wizard performs the following actions: ■Calibration ■Recover a nozzle failure ■Align the printheads for the selected media type. Define the settings for automatic calibration, nozzle failure detection, and printhead alignment in the Océ Settings Editor. See...
Page 142
142 Océ TCS400 User manual 3Press the lower softkey for Optimize print quality to enter the wizard. An introduction screen displays the message Use this wizard to optimize the print quality. A roll must be available on the printer for use during calibration. 4Press the key for Next. The screen displays the message Select roll to use. You can only calibrate on six defined media types (see ‘Overnight printing’ on page179). When calibration is not possible with the loaded media, the system asks you to...
Page 143
Ensure the best quality output 143 The screen displays feedback about the calibration process. The system does a nozzle failure recovery. You can stop the calibration process at any time. Press the key for Cancel to stop the calibration process. When there are no defective printheads, you can perform a printhead alignment. The screen displays the message All printheads OK. Perform alignment? 7Press the key for Yes. The system performs a printhead alignment. The screen displays the message Aligning...
Page 144
144 Océ TCS400 User manual Optimize the output quality from the scanner Introduction The Océ TCS400 scanner has the following methods to make sure you have a consistent output quality: ■Automatic scanner adjustment The scanner automatically makes the adjustments to make sure the quality is consistent. ■Settings on the scanner operator panel ■Scanner calibration. This section describes different methods which you can use to optimize the output quality from the scanner for your copy jobs and your...
Page 145
Ensure the best quality output 145 Problem analysis and solutions [29 ] Proble m anal ys is and sol uti ons [29] Problem analysis and solutions Problem Solutions The image on the output is some what wrong aligned.Enable the Deskew function on the System screen of the scanner opera- tor panel. Use Deskew for originals that do not contain lines or text. Deskew is especially useful for small originals. Pollution of the background of the imageUse the arrow keys to enable the Au- tom. background...
Page 146
146 Océ TCS400 User manual Calibrate the scanner Introduction To maintain a consistent quality of the output, the Océ TCS400 scanner operator panel has a calibration wizard. When to do Use the scanner calibration wizard to get consistent output of high quality. Between 2 scanner calibrations, the automatic scanner adjustment stabilizes the output quality. The automatic scanner adjustment keeps the scanner independent of changes in the environment. Use the scanner calibration wizard to start a scanner...
Page 147
Ensure the best quality output 147 How to calibrate the scanner 1 Press the upper key for System on the home screen. 2Press the lower key for Scanner calibration to enter the wizard.[39 ] Entry to the sc anner c ali bratio n wiz ard on t he Sy st em s creen. [39] Entry to the scanner calibration wizard on the System screen. The screen displays Use this wizard to calibrate the scanner and the time and the date of the last successful calibration. [40 ] Th e firs t st ep of th e sc anne r c al ibrati on...
Page 148
148 Océ TCS400 User manual 4After you cleaned the glass plate and white platen, press the key for Next. 5Place the calibration sheet face down, center aligned.[42 ] The thi rd ste p of the sc anner c ali brati on wiz ard [42] The third step of the scanner calibration wizard 6Press the key for Next. The scanner starts the calibration. The calibration takes 10 minutes. If you press the key for Cancel, the calibration process aborts. Then, the screen prompts you to remove the calibration sheet. [43 ]...
Page 149
Ensure the best quality output 149 Update the IT8 file for scanner calibration Introduction This section explains how to update the IT8 file which is paired to the scanner calibration sheet. Note:You must log on as system administrator in the Océ Settings Editor to update the IT8 file. When to do The IT8 file must match the scanner calibration sheet, which is normally found inside the front compartment of the scanner. You can find the IT8 file on the disk supplied with the scanner calibration...