Page 261

Change the media type and media size
Introduction
When you load a new type of media, the system automatically detects the new media and
asks you to enter the correct media type and the media size. When the media type or the
media size defined on the system is not correct you can change these settings.
Change the media type and size
1.From the'HOME' screen select the 'System' tab.
2.Open the 'Media' section with the confirmation button.
3.Use the scroll wheel to select 'Roll...

Page 262

Refill the toner
Refill the toner
Introduction
If the ‘Refill toner’ message appears on the user panel, you must refill the toner immedi-
ately. Use only 1 bottle of Océ PlotWave 300 toner each time the Océ PlotWave 300
indicates the toner must be refilled.
Note:
Every second time you have refilled the toner, you must also replace the residual toner
container. (see ‘Replace the residual toner container’ on page 264).
Note:
You can leave the printer turned on when you refill the toner.
How to refill the...

Page 263

3.Place the bottle on the refill opening of the toner unit.
4.Pull the slider towards you to open both the bottle and the refill opening of the toner
unit.
5.Tap the toner bottle gently (sideways) to let the toner flow from the bottle.
6.When the toner bottle is empty, return the slider of the toner unit to the original position
to close the refill opening and the toner bottle. You can now remove the toner bottle
from the opening.
Chapter 6 - Maintain the printing system
263
Refill the toner
Downloaded...

Page 264

Replace the residual toner container
Introduction
Every second time you have refilled the toner, you must also replace the residual toner
container
Note:
You can leave the printer turned on when you replace the residual toner container.
How to replace the residual toner container
1.Open the residual toner compartment.
Chapter 6 - Maintain the printing system
264
Replace the residual toner container
Downloaded From ManualsPrinter.com Manuals   

Page 265

2.Remove the full residual toner container.
Note:
The residual toner container can be disposed normally.
3.Place the empty residual toner container.
4.Close the residual toner compartment.
Chapter 6 - Maintain the printing system
265
Replace the residual toner container
Downloaded From ManualsPrinter.com Manuals   

Page 266

Maintain the scanner
Clean the scanner
Introduction
#
Description / FunctionComponent
Exits originals for reception into the front
original tray.
originals exit1
Use this ruler to measure the original.original size ruler2
original feed rollers3
scanner top cover4
scanner open levers5
original support rollers6
scanner top cover rollers7
original sensors8
Cover of the image sensors.transparent contact plates9
Use this table is you feed the original into
the scanner.
original feeding table10
Chapter 6 -...

Page 267

When to do
The copy and scan quality can decrease if
■the transparent contact plates (9) are dirty or static.
■The original support rollers are dirty and you use transparent originals.
In that case you must clean the scanner to ensure top quality output.
How to clean the scanner
1.Use both hands to push up the left and right scanner open levers (5) to fully open the
scanner top cover (4).
Chapter 6 - Maintain the printing system
267
Clean the scanner
Downloaded From ManualsPrinter.com Manuals 

Page 268

A locking mechanism prevents the scanner top cover from closing.
Attention:
To clean the scanner use the soft lint-free Masslin towels from the scanner cleaning kit.
2.Use a Masslin towel that has been moistened with water and firmly wrung out to clean
the following parts of the scanner.
Chapter 6 - Maintain the printing system
268
Clean the scanner
Downloaded From ManualsPrinter.com Manuals     

Page 269

■the original support rollers (6)
Rotate the rollers to clean them.
■the transparent contact plates (9)
Wipe off any soiled areas.
3.Wipe all the cleaned parts once again using a dry Masslin towel.
Caution:
Take care not to get your fingers caught in the scanner top cover.
4.Press the scanner top cover down gently with both hands to close it.
Note:
Check that the left and right scanner open levers are locked into position.
Chapter 6 - Maintain the printing system
269
Clean the scanner
Downloaded From...

Page 270

Calibrate the scanner
Introduction
You can calibrate the scanner when you are not satisfied with the copy or scan quality.
Use the calibration wizard to calibrate the scanner.
Before you begin
Clean the scanner before you start the calibration procedure. Dirty parts of the scanner
causes a decreased copy and scan quality. (see ‘Clean the scanner’ on page 266).
Attention:
Handle the calibration sheet with care.
Attention:
Do not touch the black area of the calibration sheet with your fingers.