Home > Nortel > Communications System > Nortel Modular Ics Companion Installer Guide

Nortel Modular Ics Companion Installer Guide

    Download as PDF Print this page Share this page

    Have a look at the manual Nortel Modular Ics Companion Installer Guide online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 211 Nortel manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Norstar Companion basics / 5
    P0992639  01 Modular  ICS  Companion Installer Guide 
    If you are using  Norstar Voice Mail with your Companion 
    system, Version 3.0 is recommended as a minimum Voice 
    Mail software version. 
    For information on how to access Norstar Voice Mail using 
    your Norstar Companion portable, refer to the Portable 
    Telephone Feature Card that is supplied with it.
    What’s new with Norstar
    This release reflects new features in the Modular ICS-XC 
    software. For a list of these changes, refer to the Modular ICS 
    Installer Guide.
    For a complete list of features supported on Companion 
    portables refer to the Modular ICS Companion System 
    Coordinator Guide. 
    						
    							6 / Norstar Companion basics
    Modular ICS Companion Installer Guide P0992639 01 
    						
    							P0992639 01 Modular ICS Companion Installer Guide
    Planning the installation
    Planning checklist
    åVerify that you have approval from UTAM Inc. 
    (U.S. only)
    åVerify that a site planner determined base station locations 
    and recorded them in the Provisioning Record.
    Required equipment and supplies 
    åCompanion portable telephones
    åCompanion base stations
    åCompanion Remote Power Interconnect device or plug top 
    Power Supplies
    åCompanion ID Labels (See Step 1: Obtain the Companion 
    ID on page 68.)
    Configuring Station Modules
    When installing wireless capabilities, use only the last two. or 
    highest numbered. ports for connecting the Companion  base 
    stations. 
    Each Station Module allows you to connect up to 16 additional 
    Norstar telephones to the system.
    Maximum number of Norstar telephones on a system
    Each Station Module that is used for Norstar Companion 
    allows you to connect up to 16 base stations to the system.
    minimidimaximega
    ICSSM3SM4SM5SM6SM7SM8SM9SM10SM11SM12
    3248648096112128144160176192 
    						
    							8 / Planning the installation
    Modular ICS Companion Installer Guide P0992639 01
    Maximum number of Norstar Companion base stations on a system
    Configuring expansion modules 
    With the addition of an Expansion Cartridge or a Combo 
    Cartridge in the ICS, you can add Trunk Modules and/or 
    Station Modules to increase your system capacity.
    Previous users of the Norstar 0X32 system should note that the 
    Key Service Unit (KSU) has been renamed the Integrated 
    Communication System (ICS).
    *The last two ports are reserved for Companion use only.
    Note:  For each type of expanded system above, Norstar 
    Companion capability is supported. Ensure you have 
    the correct Modular ICS software to support wireless 
    capability.
    minimidimaximega
    ICSSM3SM4SM7SM8SM13SM14
    16163216321632
    Installed in ICSAdditional modules allowed
    TrunkStationMaximum
    XC system
    Combo cartridge (6-port + 
    Services) (maxi)666
    Combo and 6-port cartridges 
    (mega)612*12
    Two Combo cartridges (mega)612*12
    Two 6-port cartridges (mega)612*12 
    						
    							Planning the installation / 9
    P0992639 01 Modular ICS Companion Installer Guide
    On a mini system
    Note:  Port 1 and 2 are on the ICS. 
     On a mini or non-expanded system, port 1 on the ICS (station 
    ports 101 to 132) is used for both base stations and Norstar 
    sets. No fiber ports are used since no Station Module is 
    required. Directly connect your base stations or Norstar sets to 
    port 1 on the ICS via a wiring distribution panel.
    On a midi system
    On midi and maxi systems, the highest numbered ports can be 
    used for both base stations and Norstar sets. Therefore, sets 
    and base stations can share the two highest numbered fiber 
    ports.
    A system expanded to four ports (midi size) includes one 
    2-port expansion cartridge with fiber ports numbered 3 and 4, 
    and 1 and 2 on the ICS. The base stations must be physically 
    connected (via a Station Module) to fiber ports 3 and 4 only. If 
    only one Station Module supporting base stations is required, 
    connect it to the highest-numbered port (port 4). 
    						
    							10 / Planning the installation
    Modular ICS Companion Installer Guide P0992639 01
    Two-port Expansion Cartridge
    On a maxi system
    A system expanded to eight ports (maxi size) includes one 
    6-port expansion cartridge with fiber ports numbered 3 to 8, 
    and 1 and 2 on the ICS. The base stations must be physically 
    connected, via a Station Module, to fiber ports 7 and 8 
    only.There is a maximum number of two Station Modules per 
    base station. Refer to  Six-port Expansion Cartridge with 
    Companion on page 11
    If only one Station Module supporting  base stations is 
    required, connect it to the highest-numbered port (port 8). 
    Tip - If Both ports 7 and 8 are used for connecting 
    Station Modules supporting base stations, connect 
    Trunk Modules starting at port 6 and working down. 
    Connect Station Modules for the desk sets beginning at 
    port 3 and working up.
    ICS (modules 1 and 2) TM4 SM3 
    						
    							Planning the installation / 11
    P0992639 01 Modular ICS Companion Installer Guide
    Six-port Expansion Cartridge with Companion
    On a mega system
    Keep in mind that 10 station modules is the limit for regular 
    Norstar sets, and two station modules for Companion base 
    stations is the limit on an XC configuration. 
    For example, a system expanded to 14 ports (mega size) 
    includes two 6-port expansion cartridges with fiber ports 
    numbered 3 to 14 on the expansion cartridges, and 1 and 2 on 
    the ICS. The base stations must be physically connected to 
    fiber ports 13 and 14 only. 12-port Expansion Cartridge with 
    Companion on page 12
    Tip - In the fully expanded mega configuration, Station 
    Modules 13 and 14 are reserved for base stations only.
    SM3SM4SM5 SM6 ICS (modules 1 and 2)TM8SM7 
    						
    							12 / Planning the installation
    Modular ICS Companion Installer Guide P0992639 01
    12-port Expansion Cartridge with Companion
    TM8 TM7 SM6 SM5
    ICS (modules 1 and 2)
    SM4 SM3
    SM14 SM13SM12 SM11SM10 SM9
    To Ac
    outlet
    To Ac
    outlet
    Fiber Cable Guide(max. 7 modules per power bar)
    (max. 7 modules per power bar)
    Note 1: Station modules 13 and 14
    are used for Companion
    capability only. See your Norstar
    Companion Installer Guide for
    more detail.
    Note 2: Using a 2 or 3 row layout is
    acceptable. The layout depends
    on the available wall space. 
    						
    							Planning the installation / 13
    P0992639 01 Modular ICS Companion Installer Guide
    Routing fiber cables 
    6-port Expansion Cartridge
    Fiber
    cable
    guide Upward routed fiber cable
    Downward routed fiber cable
    loose cables 
    						
    							14 / Planning the installation
    Modular ICS Companion Installer Guide P0992639 01
    ICS numbering
    Non-expanded system (ICS alone) numbering
    Two-port Expansion Cartridge and ICS numbering
    Six-port Expansion Cartridge and ICS numbering
    Module #LinesLine 
    portsB1 
    DNB2 
    DNDN 
    ports Base station 
    portsPortable 
    DN
    ICS (#2)001-
    048201-248— —— —— —— —637-696
    ICS (#1)— —— —21-5253-84101-
    132101-132637-696
    Expansion 
    module #LinesLine 
    portsB1  
    DNB2  
    DNDN 
    ports Base station 
    portsPortable 
    DN
    #4049-
    072401-
    412269-
    284333-
    348401-
    416401-416637-696
    #3073-
    096301-
    312253-
    268317-
    332301-
    316301-316637-696
    ICS (#2)001-
    048201-
    248— —— —— —— —— —
    ICS (#1)— —— —221-
    252285-
    316101-
    132— —— —
    Expansion 
    module #LinesLine 
    portsB1 
    DNB2 
    DNDN 
    port s Base station 
    portsPortable 
    DN
    #8049-
    072801-
    812333-
    348461-
    476801-
    816801-816637-696
    #7073-
    096701-
    712317-
    332445-
    460701-
    716701-716637-696
    #6097-
    108601-
    612301-
    316429-
    444601-
    616— —— —
    #5109-
    120501-
    512285-
    300413-
    428501-
    516— —— —
    #4121-
    132401-
    412269-
    284397-
    412401-
    416— —— —
    #3133-
    144301-
    312253-
    268381-
    396301-
    316— —— —
    ICS (#2)001-
    048201-
    248— —— —— —— —— —
    ICS (#1)— —— —221-
    252349-
    380101-
    132— —— — 
    						
    All Nortel manuals Comments (0)