    P0603536   02 Modular ICS 6.1 Programming Record
    Maintenance
    System version 
    (Maintenance; System version)  
    System Version Port/DN Status
    SP: Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device:
    Device: 
    						
    							74
    Modular ICS 6.1 Programming RecordP0603536   02
    Sys test log 
    (Maintenance; Sys test log)
    Sys Test Log
    Log item Time of log itemNumber of repetitions 
    						
    							75
    P0603536   02 Modular ICS 6.1 Programming Record
    Sys Admin Log 
    (Maintenance; Sys Admin Log)  
    Sys Admin Log
    Log item Time of log itemNumber of repetitions
    Time and date that log was checked 
    						
    							76
    Modular ICS 6.1 Programming RecordP0603536   02
    Network evt log 
    (Maintenance; Network evt log)  
    Network Log
    Log itemTime of log item Number of repetitions
    Time and date that log was checked 
    						
    							77
    P0603536   02 Modular ICS 6.1 Programming Record
    Template specific defaults
    For the Norstar MICS 6.1 system, the Square template is the default template. The Centrex, Hybrid, PBX 
    and DID template are also available as an option at startup. 
    For the Norstar MICS-XC 6.1 system, the PBX template is the default template. The DID template is also 
    available as an option at startup. For information on defaults for Registration, Radio data, Radios, Cells, 
    and the Registration password, refer to your MICS-XC Norstar-Companion Installer Guide. These 
    settings are used with XC 6.1 systems that use Companion components.
    The following charts show the sections of the Programming Record where the Centrex, Hybrid, PBX and 
    DID default values differ from the Square template default values.
    Terminals&Sets defaults
    Line Access
    † is a three-digit line number. The Centrex template sequentially assigns lines to DNs. It assigns Line 001 to DN221, Line 0 02 to DN 
    222, and so on, until all lines are assigned to DNs. The lines automatically become prime lines for the DNs.
    Restrictions
    SettingSquareCentrexHybridPBXDID
    Line 
    assignmen
    t Set 221
    Lines 001 to 002: 
    Appear & Ring
    other sets
    Lines 001 to 002:
    Appear & RingSet 221
    Line  
    †
    Appear & Ring
    Set 221
    Line 001: Appear & 
    Ring
    other sets
    Line 001: Appear 
    onlySet 221
    All lines: Unassigned
    other sets
    All lines:
    UnassignedSet 221
    All external lines: 
    Unassigned
    other sets
    All lines: Unassigned
    Target lines  157-284: UnassignedTarget lines 157-284: 
    Ring only
    Line pool 
    accessPool A to O: NPool A: Y
    Pool B to O: N
    Prime lineNoneLine  †I/C
    SettingSquareCentrexHybridPBXDID
    Restrn flt 01
    Restr’n 01
    Restr’n 02
    Override 001
    Override 002
    Override 003
    Restr’n 03
    Override 001
    Restr’n 04
    Restr’n 05
    Restr’n 06
    Restr’n 07
    Restr’n 08
    Restr’n 09
    Restr’n 10
    0
    1
    1800
    1877
    1888
    911
    911
    411
    976
    1976
    1976
    1900
    1900
    555121290
    91
    91800
    91877
    91888
    9911
    9911
    9411
    9976
    91976
    91976
    91900
    91900
    955512120
    1
    1800
    1877
    1888
    911
    911
    411
    976
    1976
    1976
    1900
    1900
    5551212 
    						
    							78
    Modular ICS 6.1 Programming RecordP0603536   02
    Telco features (Feature assignmnt)
    Lines defaults
    Trunk/Line data (Target lines)
    Trunk/Line data (Digital and Analog loopstart)
    SettingSquareCentrexHybridPBXDID
    Call log setNYSet 221:
    Y
    other sets:
    NNdefault
    target line: Y
    other lines: N
    Extl VMsg setNdefault target line: 
    Y
    other lines: N
    SettingSquareCentrexHybridPBXDID
    Rec’d #:NoneDN of the set it 
    appears on
    SettingSquareCentrexHybridPBXDID
    Line type PublicLines             Pool 
    001 to 030: Pool A
    031 to 060: Pool B
    061 to 068: Pool C
    069 to 076: Pool D
    077 to 084: Pool E
    085 to 092: Pool F
    093 to 0100: Pool G
    101 to 108: Pool H
    109 to 112: Pool I
    113 to 116: Pool J
    117 to 120: Pool K
    121 to 124: Pool L
    125 to 128: Pool M
    129 to 132: Pool N
    133 to 136: Pool O
    137 to 140: Public
    141 to 144: Public
    145 to 336 : PublicLines           Pool
    001 to 030: Pool A
    031 to 060: Public
    061 to 336: Public 
    						
    							79
    P0603536   02 Modular ICS 6.1 Programming Record
    Trunk/Line data (Digital and Analog Groundstart)
    Trunk/Line data (Digital and E&M lines)
    SettingSquareCentrexHybridPBXDID
    Line type PublicLines             Pool 
    001 to 030: Pool A
    031 to 060: Pool B
    061 to 068: Pool C
    069 to 076: Pool D
    077 to 084: Pool E
    085 to 092: Pool F
    093 to 0100: Pool G
    101 to 108: Pool H
    109 to 112: Pool I
    113 to 116: Pool J
    117 to 120: Pool K
    121 to 124: Pool L
    125 to 128: Pool M
    129 to 132: Pool N
    133 to 136: Pool O
    137 to 140: Public
    141 to 144: Public
    145 to 336 : PublicLines           Pool
    001 to 030: Pool A
    031 to 060: Public
    061 to 336: Public
    SettingSquareCentrexHybridPBXDID
    Line typePublicLines             Pool 
    001 to 030: Pool A
    031 to 060: Pool B
    061 to 068: Pool C
    069 to 076: Pool D
    077 to 084: Pool E
    085 to 092: Pool F
    093 to 0100: Pool G
    101 to 108: Pool H
    109 to 112: Pool I
    113 to 116: Pool J
    117 to 120: Pool K
    121 to 124: Pool L
    125 to 128: Pool M
    129 to 132: Pool N
    133 to 136: Pool O
    137 to 140: Public
    141 to 144: Public
    145 to 336 : PublicLines           Pool
    001 to 030: Pool A
    031 to 060: Public
    061 to 336: Public 
    						
    							80
    Modular ICS 6.1 Programming RecordP0603536   02
    Trunk/Line data (Digital and Analog DID)
    Trunk/Line data (BRI-2, BRI-ST, BRI-U2 and BRI-U4 lines)
    SettingSquareCentrexHybridPBXDID
    Line type PublicLines             Pool 
    001 to 030: Pool A
    031 to 060: Pool B
    061 to 068: Pool C
    069 to 076: Pool D
    077 to 084: Pool E
    085 to 092: Pool F
    093 to 0100: Pool G
    101 to 108: Pool H
    109 to 112: Pool I
    113 to 116: Pool J
    117 to 120: Pool K
    121 to 124: Pool L
    125 to 128: Pool M
    129 to 132: Pool N
    133 to 136: Pool O
    137 to 140: Public
    141 to 144: Public
    145 to 336 : PublicLines           Pool
    001 to 030: Pool A
    031 to 060: Public
    061 to 336: Public
    SettingSquareCentrexHybridPBXDID
    Line typePublicLines             Pool 
    001 to 030: Pool A
    031 to 060: Pool B
    061 to 068: Pool C
    069 to 076: Pool D
    077 to 084: Pool E
    085 to 092: Pool F
    093 to 0100: Pool G
    101 to 108: Pool H
    109 to 112: Pool I
    113 to 116: Pool J
    117 to 120: Pool K
    121 to 124: Pool L
    125 to 128: Pool M
    129 to 132: Pool N
    133 to 136: Pool O
    137 to 140: Public
    141 to 144: Public
    145 to 336 : PublicLines           Pool
    001 to 030: Pool A
    031 to 060: Public
    061 to 336: Public 
    						
    							81
    Modular ICS 6.1 Programming RecordP0603536   02
    Restrictions
    Services defaults
    Access codes
    SettingSquareCentrexHybridPBXDID
    Restrn flt 00No restrictions (cannot be changed)
    Restrn flt 01
    Restr’n 01
    Restr’n 02
    Override 001
    Override 002
    Override 003
    Restr’n 03
    Override 001
    Restr’n 04
    Restr’n 05
    Restr’n 06
    Restr’n 07
    Restr’n 08
    Restr’n 09
    Restr’n 10
    0
    1
    1800
    1877
    1888
    911
    911
    411
    976
    1976
    1976
    1900
    1900
    555121290
    91
    91800
    91877
    91888
    9911
    9911
    9411
    9976
    91976
    91976
    91900
    91900
    955512120
    1
    1800
    1877
    1888
    911
    911
    411
    976
    1976
    1976
    1900
    1900
    5551212
    SettingSquareCentrexHybridPBXDID
    Line pool codesNonePool A: 9
    Pool B to O: None
    Park prefix1
    Extrnl code9None 
    						
    							81
    P0603536   02Modular ICS 6.1 Programming Record
    Glossary of programming headings and settings
    This section presents the programming hierarchy in the Norstar Modular ICS/Modular ICS-XC interface. The dots each represent a
    level below the top level
     
    Top LevelLevel 1
    
    Level 2
    
    Level 3
    
    Below the 
    3rd level
    
    
    
    
    Menu item Description
    Profile 
    (use only at system startup)
    Change on non-North American systems, only! 
    Use this command to choose a profile that reflects the trunk card profile for 
    the specific country.
    Use Profile password.
    WARNING: Never use this command after Startup has been run.
    Dialpad 
    (use only at system startup)
    Use this command to select the dialpad layout you require. This is a system-
    wide setting.
    Use Dialpad access.
    Startup 
    (use only for initial configuration at system startup)
    Use this command to select the default information specific to your system.
    Use Startup access.
    This command is only available immediately after startup of the KSU.
     Te m p l a t eSelect the template to assign the default values for the system. 
     Start DNEnter between three and seven digits to indicate the first DN of  the range  you 
    plan to use. 
    The length of this entry also defines the default DN length and the default 
    Received number length. 
    Note: If the first digit of a DN is the same  as  any of the follow codes, the 
    system sets these codes to None:
     Direct-dial digit
     Call Park prefix
     first digit of a line pool access code 
    						