33 P0603536 02Modular ICS 6.1 Programming Record Restrictions (Terminals&Sets: Restrictions) Restrn filters (Terminals&Sets: Restrictions; Restrn filters) Restrn flt Restrn Default Overrides (Number) (Value) (Number) (Value) 00 No restrictions (only filter that cannot be changed) 01 01 0 02 1 001 1800 002 1877 0031888 03 911 001 911 04 9411 05 976 06 1976 07 1 976 08 1900 09 1 900 10 5551212 02-99 No restrictions Restrn flt Restrn nn Override (01-99) # (2digits)Restriction (max. 15 digits) # (3 digits)Overrides (max. 16 digits)
34 Modular ICS 6.1 Programming RecordP0603536 02 Restrn flt Restrn nn Override (01-99) # (2digits)Restriction (max. 15 digits) # (3 digits)Overrides (max. 16 digits)
35 P0603536 02Modular ICS 6.1 Programming Record Restrn filters - continued (Terminals&Sets: Restrictions; Restrn filters) Restrn flt Restrn nn Override (01-99) # (2digits)Restriction (max. 15 digits) # (3 digits)Overrides (max. 16 digits)
36 Modular ICS 6.1 Programming RecordP0603536 02 Set restrns (Terminals&Sets; Restrictions; Set restrns) Line/set restrns (Terminals&Sets; Restrictions; Line/set restrns) Sets: (max. 7 digits) names (max. 7 char.) Filters Normal 02 Night 11 Evening 12 Lunch 13 Sched 4 00 Sched 5 00 Sched 6 00 02, _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______02 , _______ 11 , _______ 12 , _______ 13 , _______ 00 , _______ 00 , _______ 00 , _______ Set lockNone Partial FullNone Partial FullNone Partial FullNone Partial FullNone Partial FullNone Partial FullNone Partial Full Allow last noY NYNYNYNYNYNYN Allow saved noY NYNYNYNYNYNYN Allow linkY NYNYNYNYNYNYN Normal None Night None Evening None Lunch None Sched 4 None Sched 5 None Sched 6 None __________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ ____________________ __________ __________ __________ __________ __________ __________
37 P0603536 02Modular ICS 6.1 Programming Record Telco features (Terminals&Sets:Telco features) Feature assignmnt (Terminals&Sets;Telco features; Feature assignmnt) 1stDisplay (Terminals&Sets;Telco features;1st Display) Called ID (Terminals&Sets;Telco features;Called ID) Log space (Terminals&Sets;Telco features; Log space)Sets: (max. 7 digits) names:(max. 7 char.) Caller ID set YNYNYNYNYNYNYN Extl VMsg set Line#: YNLine#: YNLine#: YNLine#: YNLine#: YNLine#: YNLine#: YN Name Numbr LineName Numbr LineName Numbr LineName Numbr LineName Numbr LineName Numbr LineName Numbr Line YN YNYNYNYNYNYN Log space (Log:0 Pool: 600)Log: Pool:Log: Pool:Log: Pool:Log: Pool:Log: Pool:Log: Pool:Log: Pool:
38 Modular ICS 6.1 Programming RecordP0603536 02 Photocopy pages before using. Lines Trunk/Line Data (Lines; Trunk/Line Data) If Target Line Trunk type (Profile 1 only)LoopE&M Ground DID BRI-ST BRI-U2 BRI-U4 PRI FixedLoopE&M Ground DID BRI-ST BRI-U2 BRI-U4 PRI FixedLoopE&M Ground DID BRI-ST BRI-U2 BRI-U4 PRI FixedLoopE&M Ground DID BRI-ST BRI-U2 BRI-U4 PRI Fixed Trunk type (Profile 2)Loop E&M Ground EURO SL1 BRI-2 BRI-STLoop E&M Ground EURO SL1 BRI-2 BRI-STLoop E&M Ground EURO SL1 BRI-2 BRI-STLoop E&M Ground EURO SL1 BRI-2 BRI-ST Trunk type (Profile 3)Loop E&M Ground DID BRI-2 BRI-STLoop E&M Ground DID BRI-2 BRI-STLoop E&M Ground DID BRI-2 BRI-STLoop E&M Ground DID BRI-2 BRI-ST Trunk type (Profile 4 only)Loop E&M Ground DID BRI-ST PRI BRI-U2 BRI-U4LoopE&M Ground DID BRI-ST PRI BRI-U2 BRI-U4LoopE&M Ground DID BRI-ST PRI BRI-U2 BRI-U4LoopE&M Ground DID BRI-ST PRI BRI-U2 BRI-U4 Line no. (3 digits) Telephone number Line typePublic Private to:_____PublicPrivate to:_____PublicPrivate to:_____PublicPrivate to:_____ Rec’d #None NoneNoneNone Prime Set221 None221None221None221None Aux. ringer YN YNYNYN If busyPrimeSetBusyTonePrimeSetBusyTonePrimeSetBusyTonePrimeSetBusyTone Distinctive ringNone , 2, 3, 4None, 2, 3, 4None, 2, 3, 4None, 2, 3, 4
39 P0603536 02 Modular ICS 6.1 Programming Record If T1 and Groundstart If T1 and Loopstart (Digital and Analog)Line no. (3 digits) Telephone number Trunk typeGround Ground Ground Ground Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ Dial mode Pulse Tone Pulse TonePulse TonePulse Tone PrimeSet221None221None221None221None Auto privacyY NYNYNYN Ans modeManual AutoManualAutoManualAutoManualAuto Ans with DISA (Only if Ans mode is Auto)Y NYNYNYN Aux. ringerYN YNYNYN Distinctive ringNone234None234None234None234 Line no. (3 digits) Telephone number Trunk typeLoop Loop Loop Loop Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ Dial mode Pulse Tone Pulse TonePulse TonePulse Tone PrimeSet221None221None221None221None Auto privacyY NYNYNYN Trunk mode (Trunk mode is Super if digital loopstart)Unspr SuperUnsprSuperUnsprSuperUnsprSuper Ans mode (Only shown if Trunk mode is Super)Manual AutoManualAutoManualAutoManualAuto Ans with DISA (Only if Ans mode is Auto)Y NYNYNYN Link at CO (Only shown for analog loopstart)YN YNYNYN Aux. ringerYNYNYNYN Full AutoHold YNYNYNYN LossPkg (Only shown for analog loopstart)ShortCO MediumCO LongCO ShortPBX LongPBXShortCO MediumCOLongCO ShortPBX LongPBXShortCO MediumCOLongCO ShortPBX LongPBXShortCO MediumCOLongCO ShortPBX LongPBX Distinctive ringNone 234None234None234None234
40 Modular ICS 6.1 Programming RecordP0603536 02 If T1 and E&M Line no. (3 digits) Telephone number Trunk typeE&M E&M E&M E&M Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ Dial mode Pulse Tone Pulse TonePulse TonePulse Tone PrimeSet221None221None221None221None Auto privacyY NYNYNYN Ans modeManual AutoManualAutoManualAutoManualAuto Ans with DISA (Only if Ans mode is Auto)Y NYNYNYN Aux. ringerYN YNYNYN SignalWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDial ANI number (Only if Signal is Wink- Start or Immediate)YN YNYNYN DNIS number (Only if signal is Wink- Start or Immediate and Ans mode is Manual)YNYNYNYN Gain (Only if analog E&M)Normal Hi ghNormal HighNormal H ighNormal High Distinctive ringNone 234None234None234None234
41 P0603536 02 Modular ICS 6.1 Programming Record If T1 and DID (Profiles 1, 3 and 4 only) Line no. (3 digits) Telephone number Trunk typeDID DID DID DID Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ Dial mode Pulse Tone Pulse TonePulse TonePulse Tone PrimeSet221None221None221None221None Ans mode (Only if analog DID)Manual AutoManualAutoManualAutoManualAuto Ans with DISA (Only if Ans mode is Auto)Y NYNYNYN Link at CO (Only if analog DID)YN YNYNYN Aux. ringerYNYNYNYN SignalWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDialWinkstart I m m e d i a t e DelayDial ANI number (Only if Signal is Wink- Start or Immediate)YN YNYNYN DNIS number (Only if signal is Wink- Start or Immediate and Ans mode is Manual)YNYNYNYN Gain (Only if analog DID)Normal Hi ghNormal HighNormal H ighNormal High Distinctive ringNone 234None234None234None234
42 Modular ICS 6.1 Programming RecordP0603536 02 If BRI-2 or BRI-ST (ISDN) (BRI-2 for Profiles 2 and 3 only) If BRI-U2 or BRI-U4 (ISDN) (Profiles 1 and 4 only) Line no. (3 digits) Telephone number (supplied by the CO) Trunk type BRI-2 BRI-ST BRI-2 BRI-ST BRI-2 BRI-ST BRI-2 BRI-ST Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ PrimeSet221None221None221None221None Auto privacyY NYNYNYN Ans mode (Trunk mode is always super)Manual AutoManualAutoManualAutoManualAuto Ans with DISA (If Ans mode is Auto)Y NYNYNYN Aux. ringerYN YNYNYN Full AutoHold YNYNYNYN Distinctive ringNone234None234None234None234 Line no. (3 digits) Telephone number (supplied by the CO) Trunk type BRI-U2 BRI-U4 BRI-U2 BRI-U4 BRI-U2 BRI-U4 BRI-U2 BRI-U4 Line typePublic Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____Public Private to: _______ Pool _____ PrimeSet221None221None221None221None Auto privacyY NYNYNYN Ans mode (Trunk mode is always super)Manual AutoManualAutoManualAutoManualAuto Ans with DISA (If Ans mode is Auto)Y NYNYNYN Aux. ringerYN YNYNYN Full AutoHold YNYNYNYN Distinctive ringNone234None234None234None234