Home > Nitsuko > Telephone > Nitsuko Portrait 308/824 Program Record Form Manual

Nitsuko Portrait 308/824 Program Record Form Manual

    Download as PDF Print this page Share this page

    Have a look at the manual Nitsuko Portrait 308/824 Program Record Form Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 57 Nitsuko manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							Program 31 - Line to Line Cut-Off Timer(Display  shows:  LN.TO LN.TIMERS)
    (1.) Path
    Connection
    Waiting
    Timer(2.)
    Warning
    Tone Timer
    for Conv.
    Cut-Off
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 31 (program number).
    2.  Press *.
    3.  Enter the option number (1 or 2) for the timer to be programmed.
    4.  Press *.
    5.  Enter the value for the timer being programmed.
    6.  Press *.
    7.  If the first option number entered was 1, you can enter the value for option number 2 OR
         Press # to exit the program.
    Program 32 - DTMF Receiver Release Timer   (Display  shows:  PB REC.REL.TIMER)
    DTMF
    Receiver
    Release
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 32 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (1.) Path Connection Waiting Timer
    000=disabled, 001 - 255 = 1 - 255
    seconds
    (2.) Warning Tone Timer for
    Conversation Cut-Off
    000=disabled, 001 - 255 = 1 - 255
    minutes
    Options
    DTMF Receiver Release Timer:
    000=disabled, 001 - 255 = 1 - 255
    seconds
    - 23 - 
    						
    							Program 33 - LND/Repeat Dial Timer(Display  shows:  LINE DROP TIMER)
      LND/
    Repeat Dial
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 33 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Program 34 - Repeat Dial(Display  shows:  REP.DIAL.TIMES)
    (1.) Waiting
    Time
    Between
    Recall(2.) Calling
    Time(3.) Number
    of Times
    Redialed
    Program Record Form Entry
    1.  Enter desired value for the counter.
    System Program Entry
    1.  Enter 34 (program number).
    2.  Press *.
    3.  Enter the value for the option.
    4.  Press *.
    5.  Press # to exit the program
    Options
    Last Number Redial/Repeat
    Dial Timer:
    000=disabled, 001 - 010 =
    1-10 seconds
    Options
    (1.) Waiting Time Between Recall
            000 = No Function, 001-255 =
            1-255 Seconds
    (2.) Calling Time
           000 = No Function, 001-255
           Seconds
    (3.) Number of Times Redialed
           001-255 = 1-255 times
    - 24 - 
    						
    							Program 35 - Class of Service(Display  shows:  CLASS OF SERVICE)
    Extension
    Port #(A.) Day
    Mode(B.) Night
    Mode(C.) Dial
    Block Class
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    1.  Enter 35 (program number).
    2.  Press *.
    3.  Enter the extension port to be programmed.
    4.  Press *.
    5.  Enter data from columns A-C.
    6.  Press *.
    7.  Enter the data for the next extension port
         displayed OR
         Press * to skip the displayed extension
         port OR
         Press # to exit program.
    Program Record Form Entry
    1.  Enter the desired Class of Service number
         in each features column.
    System Program Entry
    Options
    Enter one of the following Class of Service levels for
    options (A.), (B.), and (C.):
    0 = No Restrictions
    1 = Restricted by Program 40 [4 codes, 4 digits long).
          Allows calls matching PBX extension and
          Common Unrestricted Codes (Program 39).
    2 = Restricted by Program 41 [8 codes, 4 digits long).
          Allows Permitted Codes (Program 36), PBX
          extension calls and Common Unrestricted
          Codes (Program 39).
    3 = Restricted byProgram 37 and Program 41
          [8 Codes, 2 digits long].
          Allows PBX extension calls and Common
          Unrestricted Codes (Program 39).
    4 = Restricts all outgoing calls.
          Allows PBX extension calls and Common
          Unrestricted Codes (Program 39).
    5 = Restricted to Intercom calls only.
    - 25 - 
    						
    							Program 36 - Permitted Codes(Display  shows:  PERMITTED CODES)
    Permitted
    Code #Permitted
    Codes
    01
    02
    03
    04
    05
    06
    07
    08
    09
    10
    11
    12
    Program Record Form Entry
    1.  For each Permitted Code, program up to the first 8 digits of an allowed telephone number.  Use DC
         as a Dont Care digit within the 8 digits if it doesnt matter what number is dialed.
    System Program Entry
    1.  Enter 36 (program number).
    2.  Press *.
    3.  Enter the Permitted Code number (01-12) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Permitted Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    - 26 - 
    						
    							Program 37 - COS 3  Allowed Number of Dialed Digits(Display  shows:  DIGIT LIMIT COS3)
    Allowed
    Number of
    Dialed
    Digits
    Program Record Form Entry
    1.  Enter desired value for this option.
    System Program Entry
    1.  Enter 37 (program number).
    2.  Press *.
    3.  Enter the value for the option.
    4.  Press *.
    5.  Press # to exit the program.
    Program 38 - PBX/Centrex Access Codes(Display  shows:  PBX ACCESS CODES)
    PBX/
    Centrex
    Access
    Code #PBX/
    Centrex
    Access
    Codes
    1
    2
    3
    4
    Program Record Form Entry
    1.  For each PBX/Centrex Access Code Number, assign an access code digit (2 digits maximum).
    System Program Entry
    1.  Enter 38 (program number).
    2.  Press *.
    3.  Enter the PBX/Centrex Access Code number (1-4) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next PBX/Centrex Access Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Options
    Allowed Number of Dialed Digits
    00 = disabled, 01 - 30 = 1 - 30 digit
    limit
    Access Codes Digits:
    Digits 0-9 are accepted
    Options
    - 27 - 
    						
    							Program 39 - Common Unrestricted Codes(Display  shows:  COMM.UNRESTRICT)
    Common
    Unrestricted
    Code #Common
    Unrestricted
    Codes
    1
    2
    3
    4
    Program Record Form Entry
    1.  For each Common Unrestricted Code number, assign an access code digit (4 digits maximum).
    System Program Entry
    1.  Enter 39 (program number).
    2.  Press *.
    3.  Enter the Common Unrestricted Code number (1-4) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Common Unrestricted Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Program 40 - COS 1, Restricted Codes(Display  shows:  RESTR.CODES B)
    Restricted
    Code #Restricted
    Code
    1
    2
    3
    4
    Program Record Form Entry
    1.  For each Restricted Code number, assign a Restricted Code digit (4 digits maximum).
    System Program Entry
    1.  Enter 40 (program number).
    2.  Press *.
    3.  Enter the Restricted Code number (1-4) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Restricted Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Common Unrestricted Codes Digits:
    Digits 0-9 are accepted
    Options
    Restricted Codes Digits:
    Digits 0-9 are accepted
    Options
    - 28 - 
    						
    							Program 41 - COS 2 and 3, Restricted Codes   (Display  shows:  RESTR. CODES D2)
    Restricted
    Code #Restricted
    Code
    1
    2
    3
    4
    5
    6
    7
    8
    Program Record Form Entry
    1.  For each Restricted Code number, enter the digits to be assigned to the code number (2 digits maximum).
    System Program Entry
    1.  Enter 41 (program number).
    2.  Press *.
    3.  Enter the Restricted Code number (1-8) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Restricted Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Restricted Codes Digits:
    Digits 0-9 are accepted
    Options
    - 29 - 
    						
    							Program 42 - Walking COS Security Code(Display  shows:  UNREST.SEC.CODES)
    Security
    Code #Security
    CodeSecurity
    Code #Security
    Code
    01 16
    02 17
    03 18
    04 19
    05 20
    06 21
    07 22
    08 23
    09 24
    10 25
    11 26
    12 27
    13 28
    14 29
    15 30
    Program Record Form Entry
    1. For each Security Code number, enter the digits to be assigned to the code
    System Program Entry
    1.  Enter 42 (program number).
    2.  Press *.
    3.  Enter the Security Code number (01-30) to be programmed.
    4.  Press *.
    5.  Enter the value for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Security Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Restricted Codes Digits:
    Digits 0-9 are accepted
    Options
    - 30 - 
    						
    							Program 43-COS Assignment on Security Code(Display  shows:  UNREST.CLASS)
    Security
    Code #Class of
    ServiceSecurity
    Code #Class of
    Service
    01 16
    02 17
    03 18
    04 19
    05 20
    06 21
    07 22
    08 23
    09 24
    10 25
    11 26
    12 27
    13 28
    14 29
    15 30
    Program Record Form Entry
    1.  For each Walking Class Security Code number,
         enter a Class of Service to be assigned to the code.
    System Program Entry
    1.  Enter 43 (program number).
    2.  Press *.
    3.  Enter the Security Code number (01-30) to be programmed.
    4.  Press *.
    5.  Enter the Class of Service for the code being programmed.
    6.  Press *.
    7.  Enter the value for the next Security Code OR
         Press * to skip to the next code OR
         Press # to exit the program.
    Options
    Enter one of the following Class of Service levels for
    each Security Code:
    0 = No Restrictions
    1 = Restricted by Program 40 [4 codes, 4 digits long].
          Allows calls matching PBX extension and
          Common Unrestricted Codes (Program 39).
    2 = Restricted by Program 41 [8 codes, 4 digits long].
          Allows Permitted Codes (Program 36), PBX
          extension calls and Common Unrestricted
          Codes (Program 39).
    3 = Restricted by Program 37 and Program 41
          [8 codes, 2 digits long]
          Allows PBX extension calls and Common
          Unrestricted Codes (Program 39).
    4 = Restricts all outgoing calls.
          Allows PBX extension calls and Common
          Unrestricted Codes (Program 39).
    5 = Restricted to Intercom calls only.
    - 31 - 
    						
    							Program 44 - External Alarm Sensor(Display  shows:  ALARM SENSOR)
     Alarm #(A.) Alarm
    Installed?(B.) Alarm
    Trigger
    Condition
    1
    2
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 44 (program number).
    2.  Press *.
    3.  Enter the alarm number to be programmed.
    4.  Press *.
    5.  Enter the value from column A for the alarm being programmed.
    6.  Press *.
    7.  Enter the value from column B for the alarm being programmed.
    8.  Press *.
    9.  If the first alarm programmed was 1, you can enter alarm 2
         information by repeating steps 5-8 OR
         Press # to exit the program.
    Program 45 - Intercom Link Increase(Display  shows:  ICM LINK INCR.)
    Las t U s ed
    Line #
    Program Record Form Entry WARNING:
    1.  Enter the last line number used in the system. The system will reset upon exiting
    programming mode if this program
    System Program Entryis changed.
    1.  Enter 45 (program number).
    2.  Press *.
    3.  Enter the last line number used in the system.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (A.) Alarm Installed?
    0=not installed, 1=installed
    (B.) Alarm Trigger Condition
    Internal Power:  0=normally closed
    loop, 1=normally open loop
      OR
    External Power:  0=normally open
    loop, 1=normally closed loop
    Options
    Las t U s ed Line # :
    00 = not assigned, 01-24 = last line
    number used