    							Program 13  - Extension Options (3)(Display  shows:  STN ASSIGNMENT3)
    Extension
    Port #(A.)
    Confirm.
    Tone(B.) Do Not
    Disturb(C.) Alarm
    Audible(D.) Voice
    Announce
    Device Port(E.)      
    Terminal
    Connection
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    Options
    (A.) Confirmation Tone
    0=enabled, 1=disabled
    (B.) Do Not Disturb
    0=disabled, 1=incoming CO
    calls blocked, 2=CO and
    ICM calls blocked, 3=CO
    and ICM calls blocked or
    CO calls blocked and ICM
    calls allowed
    (C.) Alarm Audible
    0=disabled, 1=enabled
    (D.) Voice Announce Device Port
    0=disabled, 1=enabled
    (E.) Terminal Connection
    0=not connected,
    1=connected
    Program Record Form Entry
    1.  Enter the desired option
         number in for each feature.
    System Program Entry
    1.  Enter 13 (program
         number).
    2.  Press *.
    3.  Enter extension port
         number.
    4.  Press *.
    5.  Enter data from
         columns A-E.
    6.  Press *.
    7.  The next extension
         port displays. Repeat
         steps 5-6 OR
         Press * to advance
         to another extension
         port OR
         Press # to exit
         program.
    - 13 - 
    						
    							Program 14 - Flexible Station Numbering(Display  shows:  FLEX.STA.#ING)
    Extension
    Port #(A.)
    Extension
    Number
    Assigned to
    Port(B.) Number
    Plan
    10
    11
    12
    13
    14
    15
    16
    17
    18
    19
    20
    21
    22
    23
    24
    25
    26
    27
    28
    29
    30
    31
    32
    33
    Options
    (A.) Extension Number Port Assignment
    10-79 = 2-digit number plan extensions,
    110-799 = 3-digit number plan extensions
    (B.) Number Plan
    002 = 2-digit number plan assignment,
    003 = 3-digit number plan assignment
    Program Record Form Entry
    1.  Enter the extension numbers to
         be assigned to each port, and
         assign the number plan.
    System Program Entry
    To change port assignments:
    1.  Enter 14 (program number).
    2.  Press * *.
    3.  Enter the data from column B.
    4.  Press *.
    5.  Press # to exit program.
    1.  Enter 14 (program number).
    2.  Press *.
    3.  Enter data from column A.
    4.  Press *.
    5.  Enter the next extension port number
         to be assigned by repeating steps 5-6 OR
         Press * to skip the displayed port OR
         Press # to exit program.
    To change the system numbering plan:
    - 14 - 
    						
    							Program 15  - System Options (1)(Display  shows:  SYS ASSIGNMENT1)
    (A.) Flexible
    Line
    Appearance(B.) Night
    Transfer(C.)
    Automatic
    Line Access(D.)
    Exclusive
    Hold(E.) Single
    Step Access
    Program Record Form Entry
    1.  Enter desired option number in each
         features column.
    System Program Entry
    1.  Enter 15 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Program 16  - System Options (2)(Display  shows:  SYS ASSIGNMENT2)
    (A.) Ringing
    Line
    Preference(B.)
    Recalling
    Line
    Preference(C.) Allow
    SLT to
    Access Line
    on Hold(D.)
    Add-On
    Conference
    Setup Mode(E.)
    Multi-Line
    Conference
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 16 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (A.) Flexible Line Appearance
    0=disabled, 1=enabled
    (B.) Night Transfer
    0=all tenants, 1=each tenant
    (C.) Automatic Line Access
    0=disabled, 1=press SPK key and
    queuing group number, 2=dial 0 from
    on-hook condition, 3=press SPK key
    and queuing group number and dial 0
    from on-hook condition
    (D.) Exclusive Hold
    0=disabled, 1=enabled
    (E.) Single Step Access
    0=disabled, 1=enabled
    Options
    (A.) Ringing Line Preference
    0=disabled, 1=all incoming calls to Group
    1 and ringing incoming calls to Group 2,
    2=incoming ringing calls to Group 1 and
    Group 2
    (B.) Recalling Line Preference
    0=disabled, 1=enabled
    (C.) Allow SLT to Access Line on Hold
    0=no access for line on hold, 1=can
    access line on hold
    (D.) Add-On Conference Setup Mode
    0=increase one by one, 1=increase 5
    parties at once
    (E.) Multi=Line Conference
    0=disabled, 1=enabled
    - 15 - 
    						
    							Program 17  - System Options (3)(Display  shows:  SYS ASSIGNMENT3)
    (A.) Dial
    Pulse
    Sender
    Speed(B.)
    Make/Break
    Ratio(C.) DTMF
    Duration(D.) Storage
    Quantity of
    Speed Dial(E.)
    Existence of
    Attendant
    for DISA
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 17 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Program 18  - System Options (4)(Display  shows:  SYS ASSIGNMENT4)
    (A.) Three
    Minute
    Warning
    Tone(B.) Not
    Used(C.) Speed
    Dialing
    Restriction(D.)
    Handset
    Receiver
    Volume(E.) Time
    Indication
    0
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 18 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (A.) Dial Pulse Sender Speed
    0=10 PPS, 1=20 PPS
    (B.) Make/Break Ratio
    0=33%, 1=39%
    (C.) DTMF Duration
    0=high speed (80 ms On - 80 ms Off),
    1=mid speed (100 ms On - 100 ms Off),
    2=low speed (150 ms On - 150 ms Off)
    (D.) Storage Quantity of Speed Dial
    0=100 (numbers range from 00-99), 1=200
    (numbers range from 000-199)
    (E.)  Existence of Attendant for DISA
    0=none, 1=day mode, 2=night mode,
    3=day and night mode
    Options
    (A.) Three Minute Warning Tone
    0=disabled, 1=enabled
    (B.) Not Used
    Must be set to 0
    (C.) Speed Dialing Restriction
    0=not restricted, 1=restricted
    (D.) Handset Receiver Volume
    0=reset after conversation, 1=keep
    current volume
    (E.) Time Indication
    0=12 hour mode, 1=24 hour mode
    - 16 - 
    						
    							Program 19  - System Options (5)(Display  shows:  SYS ASSIGNMENT5)
    (A.) All Call
    to External
    Zone   (B.)  
    Intercom
    Signaling(C.)
    Microphone
    On/Off(D.) Room
    Monitor(E.) Not
    Used
    0
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 19 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Program 20  - System Options (6)(Display  shows:  SYS ASSIGNMENT6)
    (A.) Door
    Chime Tone
    Duration(B.) Paging
    Splash Tone(C.) Door
    Alert Tone(D.)
    Automatic
    Line Access
    Code for
    SLT(E.)
    Existence of
    Door Box
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 20 (program number).
    2.  Press *.
    3.  Enter the data from columns A-E.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (A.) All Call to External Zone
    0=disabled, 1=speaker 1,
    2=speaker 2, 3=speaker 1 and 2
    (Option 2 and 3 not used in
    Portrait 308)
    (B.) Intercom Signaling
    0=voice call, 1=forced ring signal
    (C.) Microphone On/Off
    0=on, 1=off
    (D.) Room Monitor
    0=disabled, 1=enabled
    (E.) Not Used
    Must be set to 0
    Options
    (A.) Door Chime Tone Duration
    0=2 times, 1=30 seconds
    (B.) Paging Splash Tone
    0=disabled, 1=enabled
    (C.) Door Alert Tone
    0=disabled, 1=enabled
    (D.) Automatic Line Access Code
    for SLT
    0=off-hook and dial 0, 1=off-
    hook and dial 9
    (E.) Door Box
    0=none, 1=Door Box 1 enabled,
    2=Door Box 2 enabled, 3=Door
    Box 1 and 2 enabled
    - 17 - 
    						
    							Program 21  - Exclusive Hold Timers(Display  shows:  EXC.HOLD TIMERS)
    (1.) Recall
    Start Time(2.) Recall
    Signal
    Duration
    Time
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 21 (program number).
    2.  Press *.
    3.  Enter the option number to be programmed (1 or 2).
    4.  Press *.
    5.  Enter the value for the option being programmed.
    6.  Press *.
    7.  If the first option number entered was 1, you can enter the value for option number 2 OR
         Press # to exit the program.
    Program 22  - System Hold Timers(Display  shows:  SYS.HOLD TIMERS)
    (1.) Recall
    Timer(2.)
    Duration
    Timer
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 22 (program number).
    2.  Press *.
    3.  Enter the option number to be programmed (1 or 2).
    4.  Press *.
    5.  Enter the value for the option being programmed.
    6.  Press *.
    7.  If the first option number entered was 1, you can enter the value for option number 2 OR
         Press # to exit the program.
    Options
    (1.) Recall Start Time
    000=not assigned, 001-225 =
    10-2550 seconds
    (2.) Recall Signal Duration Time
    000=not assigned, 001-225 =
    1-255 seconds
    Options
    (1.) Recall Timer
    000=not assigned, 001-225 =
    10-2550 seconds
    (2.) Duration Timer
    000=not assigned, 001-225 =
    1-255 seconds
    - 18 - 
    						
    							Program 23 - Unscreened Transfer Recall(Display  shows:  UNANN.XFER TIMER)
    Unscreened
    Transfer
    Recall
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 23 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Program 24  - Screened Transfer Recall(Display  shows:  ANND XFER TIMER)
    Screened
    Transfer
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 24 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    Unscreened Transfer Recall Timer
    000=disabled, 001 - 255 = 10-2550
    seconds
    Options
    Screened Transfer Recall Timer
    000=disabled, 001 - 255 =
    10-2550 seconds
    - 19 - 
    						
    							Program 25 - Call Duration Timer(Display  shows:  CALL DUR. START)
     Call
    Duration
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 25 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Program 26 - Flash Timer(Display  shows:  FLASH TIMER)
    (1.) CO Line
    Flash Timer(2.) PBX/
    Centrex
    Line Flas h
    Timer
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 26 (program number).
    2.  Press *.
    3.  Enter the option number to be programmed.
    4.  Press *.
    5.  Enter the value for the option being programmed.
    6.  Press *.
    7.  If the first option number entered was 1, you can enter the value for option number 2 OR
         Press # to exit the program.
    Options
    Call Duration Timer
    000=disabled, 001 - 180 = 1-180 seconds
    Options
    (1.) CO Line Flash Timer
    000 = not assigned, 001 - 250 =
    10 - 2500 ms
    (2.) PBX/Centrex Line Flash Timer
    000 = not assigned, 001 - 250 =
    10 - 2500 ms
    - 20 - 
    						
    							Program 27 - SMDR Timer(Display  shows:  SMDR TIMERS)
    (1.) Call
    Duration
    Timer(2.) Call
    Start Timer
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 27 (program number).
    2.  Press *.
    3.  Enter the value for the Call Duration Timer.
    4.  Press *.
    5.  Enter the value for the Call Start Timer.
    6.  Press *.
    7.  Press # to exit the program.
    Program 28 - Call Forward Transfer Timer(Display  shows:  DELAY RING TIMER)
    Call
    Forward
    Transfer
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 28 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Options
    (1.)  Call Duration Timer
    00 = starts immediately,
    01 - 60 = 1 - 60 seconds
    (2.) Call Start Timer
    00=starts immediately,
    01 - 60 = 1 - 60 seconds
    Options
    Delay Ring Transfer Timer
    000=disabled, 001 - 255 = 1-255 seconds
    - 21 - 
    						
    							Program 29 - Attendant Reverting(Display  shows:  ATT.REVERT TIMER)
    Attendant 
    Revert 
    Timer
    Program Record Form Entry
    1.  Enter desired value for the timer.
    System Program Entry
    1.  Enter 29 (program number).
    2.  Press *.
    3.  Enter the value for the timer.
    4.  Press *.
    5.  Press # to exit the program.
    Program 30 - Voice Message Timer(Display  shows:  ANN.TIMERS)
    (1.)
    Automatic 
    Answering
    Timer(2.) Dial
    Tone Sent
    Timer
    Program Record Form Entry
    1.  Enter desired option number in each features column.
    System Program Entry
    1.  Enter 30 (program number).
    2.  Press *.
    3.  Enter the option number (1 or 2) for the timer to be programmed.
    4.  Press *.
    5.  Enter the value for the timer being programmed.
    6.  Press *.
    7.  If the first option number entered was 1, you can enter the value for option number 2 OR
         Press # to exit the program.
    Options
    Attendant Revert Timer
    000=disabled, 001 - 255 = 1-255 seconds
    Options
    (1.) Automatic Answering Timer
    000=disabled, 001 - 255 = 1 - 255
    seconds
    (2.) Dial Tone Sent Timer
    000=disabled, 001 - 255 = 1 - 255
    seconds
    - 22 - 
    						