Page 421
0700 - Analog Communications Interface (ACI) 0701 - Analog Communications Interface (ACI) Options DS2000 Software Manual Chapter 2: Programming413 0700 - Analog Communications Interface (ACI) 0701 - Analog Communications Interface (ACI) Options Description LCCPU 01.00.00 Not available.
Page 422
0800 - Display Messages 0801 - Selectable Display Messages 414Chapter 2: ProgrammingDS2000 Software Manual 0800 - Display Messages 0801 - Selectable Display Messages Description Use Program 0801 - Selectable Display Messages to program the system’s 16 Selectable Display Messages. Each message can be up to 20 characters long, including a blank spaces you may want to ad for readability. All messages are appendable by user-entered digits. When entering names, use Table 17: Keys for Entering Names on page...
Page 423
0800 - Display Messages 0801 - Selectable Display Messages DS2000 Software Manual Chapter 2: Programming415 1. Enter the programming mode. 2. 0801 + HOLD 3. Enter the number of the message you want to program + HOLD. The previously programmed message displays. 4. Enter the new display message + HOLD. When entering a message, refer to 0506 - ACI/CPU Analog Port Extension Numbers and Names on page 400. OR Press HOLD to leave the current value unchanged. 0801:DISPLAY MESSAGE MESSAGE NUM? 0801:DISPLAY...
Page 424
1000 - Trunk Programming 1001 - Trunk Port Description 416Chapter 2: ProgrammingDS2000 Software Manual 1000 - Trunk Programming 1001 - Trunk Port Description Description Use Program 1001 - Trunk Port Description to program various options for trunks ports. Also see Program 1003 - Trunk Options on page 426. Conditions Per FCC regulations, do not set 1001- Trunk Transmit Gain on page 417 higher than 0 dB. LCCPU 01.00.00 Available. Table 32: Program 1001 - Trunk Port Description...
Page 425
1000 - Trunk Programming 1001 - Trunk Port Description DS2000 Software Manual Chapter 2: Programming417 Trunk Transmit GainUse this option to set the trunk’s transmit gain. This gain setting allows you to com- pensate for the transmit gain characteristics of the connected telco or PBX. • See Central Office Calls, Answering on page 58 for more. • See Central Office Calls, Placing on page 63 for more. • See Direct Inward Dialing on page 87 for more. • • See PBX/Centrex Compatibility on page 222 for...
Page 426
1000 - Trunk Programming 1001 - Trunk Port Description 418Chapter 2: ProgrammingDS2000 Software Manual TRANSMIT GAIN? (Cont’d) 31 = .5 dB loss 32 = 1 dB loss 33 = 1.5 dB loss 34 = 2 dB loss 35 = 2.5 dB loss 36 = 3 dB loss 37 = 3.5 dB loss 38 = 4 dB loss 39 = 4.5 dB loss 40 = 5 dB loss 41 = 5.5 dB loss 42 = 6 dB loss 43 = 6.5 dB loss 44 = 7 dB loss 45 = 7.5 dB loss 46 = 8 dB loss 47 = 8.5 dB loss 48 = 9 dB loss 49 = 9.5 dB loss 50 = 10 dB loss 51 = 10.5 dB loss 52 = 11 dB loss 53 = 11.5 dB loss 54 = 12...
Page 427
1000 - Trunk Programming 1001 - Trunk Port Description DS2000 Software Manual Chapter 2: Programming419 Trunk Receive GainUse this option to set the trunk’s receive gain. This gain setting allows you to com- pensate for the receive gain characteristics of the connected telco or PBX. • See Central Office Calls, Answering on page 58 for more. • See Central Office Calls, Placing on page 63 for more. • See Direct Inward Dialing on page 87 for more. • • See PBX/Centrex Compatibility on page 222 for...
Page 428
1000 - Trunk Programming 1001 - Trunk Port Description 420Chapter 2: ProgrammingDS2000 Software Manual RECEIVE GAIN? (Cont’d) 31 = .5 dB loss 32 = 1 dB loss 33 = 1.5 dB loss 34 = 2 dB loss 35 = 2.5 dB loss 36 = 3 dB loss 37 = 3.5 dB loss 38 = 4 dB loss 39 = 4.5 dB loss 40 = 5 dB loss 41 = 5.5 dB loss 42 = 6 dB loss 43 = 6.5 dB loss 44 = 7 dB loss 45 = 7.5 dB loss 46 = 8 dB loss 47 = 8.5 dB loss 48 = 9 dB loss 49 = 9.5 dB loss 50 = 10 dB loss 51 = 10.5 dB loss 52 = 11 dB loss 53 = 11.5 dB loss 54 = 12...
Page 429
1000 - Trunk Programming 1001 - Trunk Port Description DS2000 Software Manual Chapter 2: Programming421 Telephone Programming Instructions 1. Enter the programming mode. 2. 1001 + HOLD 3. Enter the number of the trunk you want to program (1-16) + HOLD. The previously programmed value displays. 4. Enter the new trunk circuit type + VO L . OR Press VO L to leave the current circuit type unchanged The extension number programmed in 0504 - Trunk Port Extension Numbers on page 396displays. You cannot...
Page 430
1000 - Trunk Programming 1001 - Trunk Port Description 422Chapter 2: ProgrammingDS2000 Software Manual OR Press VO L to leave the transmit gain unchanged 8. Enter the new receive gain + VO L . OR Press VO L to leave the current receive gain unchanged 9. Enter the new Class of Service for the trunk + VO L . OR Press VO L to leave the current Class of Service unchanged 10. Enter Y ro assign or N to unassign the line as a PBX line + VO L . OR Press VO L to leave the current assignment...