Page 301

System Timers
DS2000 Software ManualChapter 1: Features293
Conditions
None
Default Setting
See the table above.
Programming List
Program 0401 - System Timers (page 375)
The system-wide timers allow the adminstrator system performance to meet the specific appli-
cation requirements. 
DIL No AnswerThis timer sets how long a DIL rings an idle exten-
sion before Key Ring occurs. Key Ring rings all 
extensions programmed to ring for that line.15 sec.
Trunk RevertThis timer sets how long Hold Recall rings the...

Page 302

System Timers
294Chapter 1: FeaturesDS2000 Software Manual
Other Related Features
Refer to the following for related feature information:
Program 0401 - System Timers (page 375)
Feature Operation
None 

Page 303

System Timers, Stations
DS2000 Software ManualChapter 1: Features295
System Timers,  Stations
Description
The system provides many station timers that the administrator can customize. Review the tables 
below for a description of each station timer.
Following is a summary of the Program 0403 - Station Timers (page 386). LCCPU 01.00.00 Available.
Adjustable station timers allow the system to more precisely meet the site requirements.
Table 12: Program 0403 - Station Timers (Page 1 of 2)...

Page 304

System Timers, Stations
296Chapter 1: FeaturesDS2000 Software Manual
Number of Extended 
RingsIf an extension’s Class of Service enables Extended 
Ringing, use the timer to set the duration of the 
Extended Ringing.20 sec.
Drop Pulse SendUse this timer to set the duration of the ASTU PCB 
drop pulse. This pulse is sent from the ASTU PCB to 
the connected analog device to initiate a disconnect.300 mS
DTMF DetectUse this timer to set the DTMF detection threshold 
for single line (analog device) ports. If...

Page 305

System Timers, Stations
DS2000 Software ManualChapter 1: Features297
Following is a summary of the Program 0404 - Analog Station Timers (page 389).
Table 13: Program 0404 - Analog Station Timers (Page 1 of 2)
OptionDescriptionDefault
Country Data
Use this option to define the country of use and the 
codec digitizing method for ASTU PCBs. This timer 
consists of two bits (xy), with bit x defining the coun-
try and bit y defining the digitization method. For 
example, the default entry 00 is for North...

Page 306

System Timers, Stations
298Chapter 1: FeaturesDS2000 Software Manual
Conditions
None
Default Setting
Refer to the charts above.
Minimum Hookflash TimeFor ASTU PCBs, this timer defines the minimum 
amount of time the loop must be opened before the 
system starts to detect a transfer or hang up sequence. 
Open loop intervals shorter than the setting are 
ignored by the ASTU PCB.21 (105 MS)
Maximum Hookflash 
TimeFor ASTU PCBs, this timer defines the maximum 
amount of time the loop can be opened in order for...

Page 307

System Timers, Stations
DS2000 Software ManualChapter 1: Features299
Programming List
Program 0403 - Station Timers (page 386)
Customize general station timers.
Program 0404 - Analog Station Timers (page 389)
Customize analog station timers.
Other Related Features
Refer to the following for related feature information:
Program 0403 - Station Timers (page 386)
Program 0404 - Analog Station Timers (page 389)
Feature Operation
None 

Page 308

System Timers, Trunks
300Chapter 1: FeaturesDS2000 Software Manual
System Timers, Trunks
Description
The system provides many trunk timers that the administrator can customize. Review the table 
below for a description of each trunk timer.
Following is a summary of the Program 0402 - Trunk Timers (page 378). Refer also to:
Rules for Detecting Normal CO (Single) Ring on page 304.
Rules for Detecting Special (Double) Ring on page 304.
Rules for Detecting Loop Current on page 305.
 LCCPU 01.00.00...

Page 309

System Timers, Trunks
DS2000 Software ManualChapter 1: Features301
Force Idle (Trunk Guard 
Time)Use this timer to set the guard time for trunks. When 
the system disconnects a trunk (e.g., after a user hang 
up), the system keeps the line idle until this timer 
expires. The Trunk Guard Time helps prevent call col-
lisions.
If you set this interval too short, call collisions may 
occur. If too long, there will be unnecessary delays 
before you can use the trunk for a new call.25 (2.5 sec)
PBX PauseUse...

Page 310

System Timers, Trunks
302Chapter 1: FeaturesDS2000 Software Manual
Manual DTMF Tone OnThis timer sets the duration of DTMF digits for trunk 
calls manually dialed by an extension user. This is 
required because the system buffers the digits the user 
dials.
Set this timer for compatibility with the connected 
telco or PBX/Centrex. If you set this interval too 
short, the telco or PBX/Centrex may not be able to 
properly detect the DTMF digit. If too long, outbound 
dialing is unnecessarily slowed...