Page 301
System Timers DS2000 Software ManualChapter 1: Features293 Conditions None Default Setting See the table above. Programming List Program 0401 - System Timers (page 375) The system-wide timers allow the adminstrator system performance to meet the specific appli- cation requirements. DIL No AnswerThis timer sets how long a DIL rings an idle exten- sion before Key Ring occurs. Key Ring rings all extensions programmed to ring for that line.15 sec. Trunk RevertThis timer sets how long Hold Recall rings the...
Page 302
System Timers 294Chapter 1: FeaturesDS2000 Software Manual Other Related Features Refer to the following for related feature information: Program 0401 - System Timers (page 375) Feature Operation None
Page 303
System Timers, Stations DS2000 Software ManualChapter 1: Features295 System Timers, Stations Description The system provides many station timers that the administrator can customize. Review the tables below for a description of each station timer. Following is a summary of the Program 0403 - Station Timers (page 386). LCCPU 01.00.00 Available. Adjustable station timers allow the system to more precisely meet the site requirements. Table 12: Program 0403 - Station Timers (Page 1 of 2)...
Page 304
System Timers, Stations 296Chapter 1: FeaturesDS2000 Software Manual Number of Extended RingsIf an extension’s Class of Service enables Extended Ringing, use the timer to set the duration of the Extended Ringing.20 sec. Drop Pulse SendUse this timer to set the duration of the ASTU PCB drop pulse. This pulse is sent from the ASTU PCB to the connected analog device to initiate a disconnect.300 mS DTMF DetectUse this timer to set the DTMF detection threshold for single line (analog device) ports. If...
Page 305
System Timers, Stations DS2000 Software ManualChapter 1: Features297 Following is a summary of the Program 0404 - Analog Station Timers (page 389). Table 13: Program 0404 - Analog Station Timers (Page 1 of 2) OptionDescriptionDefault Country Data Use this option to define the country of use and the codec digitizing method for ASTU PCBs. This timer consists of two bits (xy), with bit x defining the coun- try and bit y defining the digitization method. For example, the default entry 00 is for North...
Page 306
System Timers, Stations 298Chapter 1: FeaturesDS2000 Software Manual Conditions None Default Setting Refer to the charts above. Minimum Hookflash TimeFor ASTU PCBs, this timer defines the minimum amount of time the loop must be opened before the system starts to detect a transfer or hang up sequence. Open loop intervals shorter than the setting are ignored by the ASTU PCB.21 (105 MS) Maximum Hookflash TimeFor ASTU PCBs, this timer defines the maximum amount of time the loop can be opened in order for...
Page 307
System Timers, Stations DS2000 Software ManualChapter 1: Features299 Programming List Program 0403 - Station Timers (page 386) Customize general station timers. Program 0404 - Analog Station Timers (page 389) Customize analog station timers. Other Related Features Refer to the following for related feature information: Program 0403 - Station Timers (page 386) Program 0404 - Analog Station Timers (page 389) Feature Operation None
Page 308
System Timers, Trunks 300Chapter 1: FeaturesDS2000 Software Manual System Timers, Trunks Description The system provides many trunk timers that the administrator can customize. Review the table below for a description of each trunk timer. Following is a summary of the Program 0402 - Trunk Timers (page 378). Refer also to: Rules for Detecting Normal CO (Single) Ring on page 304. Rules for Detecting Special (Double) Ring on page 304. Rules for Detecting Loop Current on page 305. LCCPU 01.00.00...
Page 309
System Timers, Trunks DS2000 Software ManualChapter 1: Features301 Force Idle (Trunk Guard Time)Use this timer to set the guard time for trunks. When the system disconnects a trunk (e.g., after a user hang up), the system keeps the line idle until this timer expires. The Trunk Guard Time helps prevent call col- lisions. If you set this interval too short, call collisions may occur. If too long, there will be unnecessary delays before you can use the trunk for a new call.25 (2.5 sec) PBX PauseUse...
Page 310
System Timers, Trunks 302Chapter 1: FeaturesDS2000 Software Manual Manual DTMF Tone OnThis timer sets the duration of DTMF digits for trunk calls manually dialed by an extension user. This is required because the system buffers the digits the user dials. Set this timer for compatibility with the connected telco or PBX/Centrex. If you set this interval too short, the telco or PBX/Centrex may not be able to properly detect the DTMF digit. If too long, outbound dialing is unnecessarily slowed...