Page 911

1000 - Extension Options1001 - Basic Extension Port Setup (Part A)
 Sorts Data
✔ Updates CEU
✔  Can be Copied
Description
 124i Available — 72 extension ports. 384i Available — 256 extension ports.
INUse Program 1001 - Basic Extension Port Setup (Part A) to set the basic options of each extension port. Also
see Program 1008 for Basic Extension Port Setup (Part B) of page 893. Refer to the following chart for a de-
scription of each option, its range and default setting.
Basic Extension Port Setup...

Page 912

Single Line Ring Options
When you use these settings . . . Calls ring like this . . .
Program 1001
Item 6Program 1008
Item 4Transferred Trunk
CallRing Group Calls
and DILsIntercom Call
0 0 Long ring followed
by short pause2 short rings
followed by a pause1 second on
followed by 1
second off
1 0 1 second on
followed by 1
second off1 second on
followed by 1
second off1 second on
followed by 1
second off
0 1 Continuous ringing Continuous ringing Continuous ringing
1 1 1 second on
followed by 1
second...

Page 913

OR
HOLD + HOLD to exit.
1000 - Extension Options
1001 - Basic Extension Port Setup (Part A)
92000SWG08   Issue 1-0 PROGRAMMING   877 

Page 914

1002 - Extension Tenant
✔ Sorts Data  Updates CEU
✔  Can be Copied
Description
 124i Not available. 384i Available — four Tenant Groups.
INUse Program 1002 - Extension Tenant to assign an extension to a Tenant Group. The system allows up to four
Tenant Groups (1-4).
Conditions
None
Feature Cross Reference
Tenant Service
Telephone Programming Instructions
To enter data for Program 1002 (Extension Tenant):
1. Enter the programming mode.
2. 1002 + HOLD
STA PORT No?
3. Enter the number of the extension...

Page 915

1003 - Extension (Department) Groups
✔  Sorts Data   Updates CEU   Can be Copied
Description
 124i Available — eight extension groups
and 96 extensions/virtual extensions. 384i Available — 32 extension groups
and 384 extensions/virtual
extensions.
INUse Program 1003 - Extension (Department) Groups to set the Extension Groups. The system uses these
groups for Department Calling. Assign pilot numbers to Extension Groups you set up in Program 0506. This lets
system users place calls to the departments....

Page 916

1004 - Toll Restriction Class
 Sorts Data  Updates CEU
✔  Can be Copied
Description
 124i Available — eight Toll Restriction
classes and 72 extensions 384i Available — 15 Toll Restriction
classes in each Tenant Group and
256 extensions.
INUse Program 1004 - Toll Restriction Class to assign a Toll Restriction class to an extension. The 384i system
has 15 Toll Restriction classes in each Tenant Group. The 124i system as eight Toll Restriction classes. For an
extension, you make one entry for each Night...

Page 917

13. HOLD
STA PORT No?
14. Repeat from step 3 to program another extension port.
OR
HOLD to exit.
1000 - Extension Options
1004 - Toll Restriction Class
92000SWG08   Issue 1-0 PROGRAMMING   881 

Page 918

1005 - Class of Service
 Sorts Data  Updates CEU
✔  Can be Copied
Description
 124i Available — 10 Classes of Service
and 96 extension/virtual extension
ports. 384i Available — 15 Classes of Service in
each Tenant Group and 384
extension/virtual extension ports.
INUse Program 1005 - Class of Service to assign a Class of Service to an extension. The 384i system has 15
Classes of Service in each Tenant Group. The 124i system has 10 Classes of Service. To specify the options
in each Class of Service,...

Page 919

1006 - Programming Function Keys (Part A)
 Sorts Data  Updates CEU
✔  Can be Copied
Description
 124i Available — 72 extensions. 384i Available — 256 extensions.
INUse Program 1006 - Programming Function Keys (Part A) to set the functions of an extension’s Programma-
ble Function Keys. For certain functions, you can append data to the key’s basic function. For example, the func-
tion 1009 appended by data 1 makes a Group Call Pickup key for Pickup Group 1. You can also program
Function Keys using...

Page 920

Table 1-4, Function Key Codes by Feature
To program a key, press CALL, dial 851, press the key and enter the code (e.g., 1057 for Voice Over).
For this feature... Use this key... When you are...  Key Lamp StatusAlso see
Srvc Code
Automatic Call
Distribution (ACD)
(Cont’d)
(Refer to the Automatic
Call Distribution (ACD)
Manual, P/N
92000ACD**).Code: 1050
Operation: Press keyOut of Service
Taking an ACD Group out of
Service (for Group
Supervisors only), or Taking
all ACD Groups out of service
(for System...