NDA-30078 Revision 1.0Page 69 UCD-XL Installation Guide UCD-XL Utilities Appendix B UCD-XL Utilities There are four utility programs that enable the UNIX system administrator to access the shared memory and semaphore set utilized by the components of UCD- XL. These programs are located in directory /oai/app/ucdxl and may be run from the UNIX command line. Note: Upon initialization, the Monitor clears shared memory and the semaphore set, creating them if necessary. chkbins [] Shared memory key...
Page 72
Page 70NDA-30078 Revision 1.0 UCD-XL Utilities UCD-XL Installation Guide This utility checks the set of two semaphores utilized by UCD-XL on a periodic basis. The first semaphore is a flag that prevents more than one UCD-XL component from modifying shared memory simultaneously: 1 = unlocked, 0 = locked. The second semaphore is equivalent to a count of outstanding requests. Every Messenger waits for this semaphore to become non-zero, then takes its turn reading the next outstanding request in...
Page 73
NDA-30078 Revision 1.0Page 71 UCD-XL Installation Guide UCD-XL Environment and Hardware Appendix C UCD-XL Environment and Hardware This appendix describes the physical environment and hardware needed to support UCD-XL. A Digiboard DigiCHANNEL, NEC Multi-8/16, or similar serial communications board is required in the UAP to supply sufficient ports for the MCI links among the PBX, the VMS, and UAP (UCD-XL). RS232 cables comprise the links. Connectors may be DB-25 (25 pins) or RJ-45 (8 pins)...
Page 74
Page 72NDA-30078 Revision 1.0 UCD-XL Environment and Hardware UCD-XL Installation Guide The NEC Multi-8 and Multi-16 Boards are DTE devices that use RJ-45 connectors. The signals are laid out on a Multi-8/16 RJ-45 connector as follows: The MCI link between A/B box #1 (the PBX side) and the NEC Multi-8/16 Board on the UAP requires an adapter that connects DTE (Multi-8/16) to DCE (PBX). This wiring configuration is as follows: Table C-1 RJ-45 Pin Assignments for NEC Multi-8/16 Board Signal...
Page 75
NDA-30078 Revision 1.0Page 73 UCD-XL Installation Guide UCD-XL Environment and Hardware The MCI link between A/B box #2 (the VMS side) and the NEC Multi-8/16 Board on the UAP requires an adapter that connects DTE (Multi-8/16) to DTE (VMS). This wiring configuration is as follows: Table C-3 Adapter for Multi-8/16 to VMS Multi-8/16 Side VMS Side SignalRJ-45 PinSignalDB-25 Pin TXD 2 RXD 3 DTR 3 DCD 8 RT S 4 CTS 5 SGND 5 SGND 7 CGND 6 CGND 1 RXD 7 TXD 2 CTS 8 RT S 4 DCD 9 DTR 20
Page 76
Page 74NDA-30078 Revision 1.0 UCD-XL Environment and Hardware UCD-XL Installation Guide The Digiboard DigiCHANNEL serial communications board is a DTE device that uses either RJ-45 or DB-25 connectors. The pin assignments for both types are given below: For the connection between A/B box #1 (PBX side) and the DigiCHANNEL on the UAP, there is no special wiring unless an RJ-45/DB-25 adapter is needed. In that case, the signals are maintained by wiring together the RJ-45 and DB-25 pins for each...
Page 77
NDA-30078 Revision 1.0Page 75 UCD-XL Installation Guide UCD-XL Environment and Hardware For the connection between A/B box #2 (VMS side) and the DigiCHANNEL on the UAP, the following wiring configuration is needed to form a DTE-DTE connection: The previous information was extracted from the BusinessMate 386/25 Multi- 8/Multi-16 Reference Guide, copyright 1990 by NEC Corporation, and the DigiCHANNEL PC/8i and DigiCHANNEL PC/4i Installation Guide/Reference Manual, copyright 1989 by DigiBoard...
Page 78
UCD-XL Environment and Hardware UCD-XL Installation Guide Page 76NDA-30078 Revision 1.0 This Page Left Blank.