NDA-30080 Revision 1.0Page 61 Sentry Installation Guide Emergency Conference Configuration The Emergency Conference software is configured automatically during installation if you answer “yes” to the autoconfig prompt. You may also configure Emergency Conference manually by using the Add Function of the Application Configuration option on the APM System Administration menu. The default application name is Sentry_Conference. Note: This section contains information that is entered in the Emergency...
Page 72
Page 62NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide Primary Configuration ParametersThese parameters are defined automatically if you answered “yes” to the autoconfig prompt during installation. On the APM Configuration Entry screen, make the entries indicated below for each Emergency Conference parameter. Entries for parameters marked by an asterisk (*) must be made exactly as shown. Other entries are examples and are site-dependent. Note: Use the instructions provided...
Page 73
NDA-30080 Revision 1.0Page 63 Sentry Installation Guide Emergency Conference OAI FacilitiesThese NEAX 2400 facilities are set up automatically if you answered “yes” to the autoconfig prompt during installation. To manually set up the facilities, use the Facilities command on the APM Configuration Entry screen and follow the instructions in the APM Operations Manual. Secondary OAI Configuration ParametersThese parameters are defined automatically if you answered “yes” to the autoconfig prompt...
Page 74
Page 64NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide User-Defined Parameters Note:The following parameters contain configuration pairs consisting of a keyword, at least one blank space, and an option. Multiple configuration pairs may be specified in a single parameter if space permits. Case is ignored for keywords, but options must match exactly. The configuration pairs may occur in any order, and the following keywords and options are supported. ParameterEntryDescription...
Page 75
NDA-30080 Revision 1.0Page 65 Sentry Installation Guide Emergency Conference User Defined #7 forceCardSetClear Specifies how stations connected to dedicated card set lines are handled during initiation. Valid syntax is forceCardSetClear where “TRUE” indicates that the stations connected to dedicated card set lines are released. “FA L S E” indicates that stations connected to dedicated card set lines are not released. User Defined #8 errorDestination Specifies the extension number of the...
Page 76
Page 66NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide Database Requirements Emergency Conference requires six databases: Sentry, Conference Card, Tenant Number, Building, Contacts, and Authorized Caller. This section contains information you need to create Emergency Conference databases. Use this information with the procedural instructions in the APM Operations Manual. If you encounter messages during this process, refer to the “Process” and “Error Messages” chapters of the...
Page 77
NDA-30080 Revision 1.0Page 67 Sentry Installation Guide Emergency Conference Sentry DatabaseThe Sentry database contains information used by the Emergency Conference, Emergency Conference, and the Sentry Alarm Control Terminal applications. Each database record contains the following fields: Monitored Number The monitored number used by the caller to access the Emergency Conference or Annoyance Trap. Category An ASCII string containing the record category, which is set to ‘conference” for Emergency...
Page 78
Page 68NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide allowed to initiate this conference. If this field is blank or the specified database is empty, then this conference may be initiated from any extension. If you use the name and path of the contact database, then only the contacts can be authorized.
Page 79
NDA-30080 Revision 1.0Page 69 Sentry Installation Guide Emergency Conference Sentry Database (Continued)The Sentry master database is named “sentry_m” by default and contains the following fields. Table 4-1 Sentry Master Database Fields The Sentry application database is named “sentry” by default and contains the following fields. Table 4-2 Sentry Application Database Fields Field Description Type SizeMinimum Va l u eMaximum Va l u eExample Va l u e Monitored Number ASCII 10 5776 Category ASCII...
Page 80
Page 70NDA-30080 Revision 1.0 Emergency Conference Sentry Installation Guide Conference Card DatabaseThe conference card database contains a list of conference card sets. Conference card sets can be configured as a dedicated or pool sets. A dedicated set is reserved by specifying the first extension in the set and is normally associated with a specific conference. A pool set is reserved on a first come, first serve basis and can be used by several conferences sequentially. Each conference card...