Page 21
NDA-30080 Revision 1.0Page 11 Sentry Installation Guide Sentry Alarm Control Terminal 11. Press Enter to continue the installation. 12. Press Enter to continue. The following screen displays when the installation is complete. 13. Press Enter. Installing the Sentry Terminal Binary . . . NEC America Inc Sentry Terminal Installation Wed - Apr 29, 1998 Installing the Sentry Database Files . . .Installing the Default Terminal Configuration Files . . .Installing the ansi_sat terminal information . ....
Page 22
Page 12NDA-30080 Revision 1.0 Sentry Alarm Control Terminal Sentry Installation Guide UNIX Subsystem Database UpdateThe SCO UNIX Subsystem database must be updated for the Sentry Alarm Control Terminal. At the UNIX prompt, login as the superuser (root) and execute the SCO UNIX Subsystem Database authorization checking program (/tcb/bin/authck -s) and password deletion program (passwd -d) as shown below. Answer yes when asked to fix the subsystem databases. This ensures that the SCO UNIX...
Page 23
NDA-30080 Revision 1.0Page 13 Sentry Installation Guide Sentry Alarm Control Terminal Database Creation The Sentry Master Database contains information used by the Emergency Conference, Annoyance Trap, and Sentry Alarm Control Terminal applications. The Feature Application Database contains a sub set of the Sentry Master Database and is used by the Sentry Alarm Control Terminal program. Each feature database record contains an entry for each Sentry feature (Emergency Conference or Annoyance Trap)...
Page 24
Page 14NDA-30080 Revision 1.0 Sentry Alarm Control Terminal Sentry Installation Guide Sentry Master DatabaseThe Sentry master database is named “sentry_m” by default and contains the following fields. Table 2-1 Sentry Master Database Fields Feature Application DatabaseThe feature application database uses data contained in the sentry master database. It is called “features” by default and contains the following fields. Table 2-2 Feature Application Database Fields Field Description Type...
Page 25
NDA-30080 Revision 1.0Page 15 Sentry Installation Guide Sentry Alarm Control Terminal Window Configuration Files To create window configuration files: 1. Log in as apmadm to access the APM Administration Main Menu. 2. At the APM Administration Main Menu, type U to exit to UNIX. 3. At the UNIX prompt, type the following to change to the Sentry Alarm Control Terminal default configuration directory: cd /oai/app/sentry/cfg/terminals/default 4. Make a feature configuration file for each Sentry Feature by...
Page 26
Page 16NDA-30080 Revision 1.0 Sentry Alarm Control Terminal Sentry Installation Guide Configuration Parameters The Sentry Alarm Control Terminal application uses configuration parameters defined in configuration files found in the “/oai/app/sentry/cfg/terminals” directory. The following sections describe the formats and functionality of these files. Master Configuration FileWhen a Sentry Alarm Control Terminal is started it will determine which UNIX tty device it is using (tty01, tty02, etc.). It...
Page 27
NDA-30080 Revision 1.0Page 17 Sentry Installation Guide Sentry Alarm Control Terminal Data Buffer Configuration FileThe data buffer configuration file, “db.cfg”, contains constants and data buffer field definitions. Data buffers are used to store fields of ASCII character information contained in messages or read from a terminal. The fields within a data buffer may be used to build configurable display strings. The data buffer configuration file contains field definitions consisting of a field...
Page 28
Page 18NDA-30080 Revision 1.0 Sentry Alarm Control Terminal Sentry Installation Guide PASS_OP_CALLER Stations with a classification of operator or caller are passed. All other stations are ignored. PASS_SRC_CALLER Stations with a classification of source or caller are passed. All other stations are ignored. PASS_SRC_OP Stations with a classification of source or operator are passed. All other stations are ignored. PASS_ALL All stations are passed. Login Screen User Name and Password Data Buffer...
Page 29
NDA-30080 Revision 1.0Page 19 Sentry Installation Guide Sentry Alarm Control Terminal Clock and Caller Information Data Buffer Configuration The clock and caller information data buffer contains date and time fields which may be used to create date and time display strings. The optional caller status fields (along with the date and time fields) are used to display caller status. The following fields are defined: MONTH_NUMThe numeric month (1...12, where 1 = January, 2 = February, etc.)...
Page 30
Page 20NDA-30080 Revision 1.0 Sentry Alarm Control Terminal Sentry Installation Guide Function Key Assignments Data Buffer Configuration The function key assignments data buffer contains the function key assignment descriptions which are displayed in the function key help dialog (see Function Key Help Dialog Configuration on page 25). A function key assignment description field corresponding to the respective function key may be defined in the function key assignment data buffer. The following...