Home > NEC > Communications System > NEC Second Party Alert User And Installation Guide

NEC Second Party Alert User And Installation Guide

Here you can view all the pages of manual NEC Second Party Alert User And Installation Guide. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 31

NDA-30041   Revision 5Page 25
Second Party Alert User and Installation Guide INSTALLATION AND CONFIGURATION
Step 3: OAI Facilities
According to instructions in the APM Operations Manual, designate the following 
NEAX2400 facilities for SPA using the Facilities command on the Configuration 
Entry screen. These facilities are automatically set up when you run autoconfig 
during installation.
Note:The same MSF Op-Code that is specified here must be assigned to SPA at the 
NEAX MAT. For more information, see...

Page 32

Page 26NDA-30041   Revision 5
INSTALLATION AND CONFIGURATION Second Party Alert User and Installation Guide
Step 4: Secondary OAI Configuration Parameters 
Using the OAI-Conf command on the APM Configuration Entry screen, make an 
for each of the following parameters. If the parameter is followed by an asterisks 
(*) in the table, you must make the entry exactly as shown. Other entries serve only 
as examples — actual entries are site-dependent. Use the instructions provided for 
this option in the APM...

Page 33

NDA-30041   Revision 5Page 27
Second Party Alert User and Installation Guide INSTALLATION AND CONFIGURATION
Step 5: User-Defined Parameters 
Make the following additional parameter entry through the UserDefined command 
on the OAI Configuration screen. These parameters are automatically set up when 
you run autoconfig during installation.
Parameter Typical Entry Description
User Defined #1  7 The OAI key code assigned on the 
MAT via the AOKC command.
User Defined #2 2 This is the chime tone value...

Page 34

INSTALLATION AND CONFIGURATION Second Party Alert User and Installation Guide
Page 28NDA-30041   Revision 5
Step 5: User-Defined Parameters (Cont)
This completes the configuration of SPA in the APM. Now go to Chapter 3, 
“DATABASE REQUIREMENTS” to create its database support.
Parameter Typical Entry Description
User Defined #8 7 This field specifies the number of 
digits used to place a local call. 
Valid values for this field are 7 (7 
digit phone number only) and 10 
(area code + 7 digit phone number)....

Page 35

NDA-30041   Revision 5Page 29
Second Party Alert User and Installation Guide DATABASE REQUIREMENTS
Chapter 3 DATABASE REQUIREMENTS
This chapter assumes that SPA is not going to use the OAI Name Display 
application database and must have one built. In this case, SPA requires two 
databases that are created through the Database Administration option on the APM 
System Administration Menu.
Database creation in the APM involves the following 4-step process:
Step 1 - Create a Master Definition File: This...

Page 36

Page 30NDA-30041   Revision 5
DATABASE REQUIREMENTS Second Party Alert User and Installation Guide
Name Display 
Database 
InformationThe Name Display database field entries are shown in the following table and 
defined below the table. Name the Master Definition File name_m and the 
Application Definition File nmdsp.
Note 1:
You do not have to create this database if the Name Display application is 
installed, and its database is going to be used.
Note 2:
Name the name_m
 file in the Define Master...

Page 37

NDA-30041   Revision 5Page 31
Second Party Alert User and Installation Guide DATABASE REQUIREMENTS
Phone Line 
Database 
InformationThe Phone Line database field entries are shown below in the table and defined 
below the table. Name the Master Definition File phone_m and the Application 
Definition File phonline.
Note:
Name the phone_m
 file in the Define Master Database Fields option, chosen 
from the Build Master Database option on the Database Administration menu. 
Name the phonline
 file in the...

Page 38

Page 32NDA-30041   Revision 5
DATABASE REQUIREMENTS Second Party Alert User and Installation Guide
Tenant Number 
Database 
InformationThe Tenant Number database field entries are shown below in the table and defined 
below the table. The database contains a list of extensions and associated tenant 
numbers used by the PBX. A tenant number can be associated with an individual 
numeric extension or a range of numeric extensions. A given tenant number can 
have more than one record if all of the extensions...

Page 39

NDA-30041   Revision 5Page 33
Second Party Alert User and Installation Guide MAT ASSIGNMENTS
Chapter 4 MAT ASSIGNMENTS
This guide assumes that data settings that affect the operation of all OAI software 
on a system-wide basis have already been assigned on the NEAX Maintenance 
Administration Terminal (MAT). Such settings include system index values and 
assignment of Interface I/O Port Data in the Interface Processor (IP). For more 
information about these system data settings and the MAT commands...

Page 40

Page 34NDA-30041   Revision 5
MAT ASSIGNMENTS Second Party Alert User and Installation Guide
AIPT Command: (Assignment of Interface I/O Port Data in IP)
This command can be used to assign TCP/IP address of the system’s IP. Let system 
and UAP both in ethernet.
IP-NO: Assign face Processor Number.
Port Number
PNI: Assign 1
KIND: Assign 3 for choose TCP/IP protocol.
Assign ETHER-PKGNO
Assign TCP/IP address
ASYD Command: Assignment of System Data
If the Name Display application is not installed and a...
Start reading NEC Second Party Alert User And Installation Guide