Home > NEC > Communications System > NEC Property Management System Communication Interface Specification

NEC Property Management System Communication Interface Specification

    Download as PDF Print this page Share this page

    Have a look at the manual NEC Property Management System Communication Interface Specification online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.

    							NDA-30115  Revision 1.0Page C-1
    Property Management System - Communication Interface Feature Codes
    Appendix C Feature Codes
    Feature Code Description
    70 Data Link Maintenance
    11, 12, 51, 52 Maid Status
    13, 53 Message Waiting Lamp Control
    15 Restriction Control
    16 Check-In/Out (Model 60)
    56 Check-In/Out (Model 90)
    17 Extension Report
    17 Room Recovery (Model 60)
    57 Room Recovery (Model 90)
    19 Wake Up/Group Announcement
    20 Room Move/Swap/Copy (Model 60)
    21, 61 Room Data Change
    59 Direct Data Entry (Model 90)
    62 Extension Connection 
    						
    							Feature Codes Property Management System - Communication Interface
    Page C-2NDA-30115  Revision 1.0
    This Page Left Blank. 
    						
    							NDA-30115  Revision 1.0Page D-1
    Property Management System - Communication Interface Function Codes
    Appendix D Function Codes
    FTC FC Description Source Model
    70 0 Nop Test Normal Answer NEAX ALL
    70 2 Nop Test Recover Answer NEAX ALL
    70 3 Recovery Start Report PMS ALL
    70 4 Recovery End Report PMS ALL
    70 5 Data Link Release Request PMS/NEAX ALL
    70 6 Data Link Release Confirmation PMS/NEAX ALL
    70 8 Extension Number Request PMS ALL
    70 F Nop Test PMS ALL
    11 1 Cleaning Start (Guest) NEAX ALL
    11 2 Cleaning End (Guest) NEAX ALL
    11 3 Inspection End (Guest) NEAX ALL
    11 4 Out of Order (Guest) NEAX ALL
    12 1 Cleaning Start (Administration) NEAX ALL
    12 2 Cleaning End (Administration) NEAX ALL
    12 3 Inspection End (Administration) NEAX ALL
    51 1 Guest Room 1 NEAX 90
    51 2 Guest Room 2 NEAX 90
    51 3 Guest Room 3 NEAX 90
    51 4 Guest Room 4 NEAX 90
    51 5 Guest Room 5 NEAX 90
    51 6 Guest Room 6 NEAX 90
    51 7 Guest Room 7 NEAX 90
    51 8 Negative Answer PMS 90
    51 9 Positive Answer PMS 90
    52 1 Administration 1 NEAX 90
    52 2 Administration 2 NEAX 90
    52 3 Administration 3 NEAX 90
    52 4 Administration 4 NEAX 90
    13 1 MWL On PMS ALL
    13 2 MWL Off PMS ALL
    13 3 MWL On NEAX ALL 
    						
    							Page D-2NDA-30115  Revision 1.0
    Function Codes Property Management System - Communication Interface
    13 4 MWL Off NEAX ALL
    53 1 MWL Status PMS 90
    53 2 MWL On (FDT) NEAX 90
    53 3 MWL Off (FDT) NEAX 90
    15 1 Restriction Control PMS ALL
    15 2 Restriction Control NEAX ALL
    16 1 Check In 1 PMS 60
    16 2 Check Out PMS 60
    16 5 Check Out MWL Off Report NEAX 60
    16 6 Check Out MWL On Report NEAX 60
    16 A Check In 2 PMS 60
    16 B Check In 3 PMS 60
    16 C Check Out Outgoing Call Report NEAX ALL
    16 D Check Out Message Waiting Report NEAX 60
    56 1 Check In PMS 90
    56 2 Check Out PMS 90
    56 4 Check In Cancellation PMS 90
    56 5 Check Out Cancellation PMS 90
    56 6 Room Change PMS 90
    56 7 Provisional Check In NEAX 90
    56 8 Provisional Check Out NEAX 90
    56 9 Check Out Message Waiting Report NEAX 90
    17 E Extension Delete Report NEAX ALL
    17 F Extension Assignment Report NEAX ALL
    17 1 Room Image Set 1 (Normal Request) PMS 60
    17 2 Room Image Set 1 (Normal Answer) NEAX 60
    17 3 Room Image Set 1 (Recovery Request) PMS 60
    17 4 Room Image Set 1 (Recovery Answer) NEAX 60
    17 5 Room Image Set 2 (Normal Request) PMS 60
    17 6 Room Image Set 2 (Normal Answer) NEAX 60
    17 7 Room Image Set 2 (Recovery Request) PMS 60
    17 8 Room Image Set 2 (Recovery Answer) NEAX 60
    17 9 Room Image Set 3 (Normal Request) PMS 60
    FTC FC Description Source Model 
    						
    							NDA-30115  Revision 1.0Page D-3
    Property Management System - Communication Interface Function Codes
    17 A Room Image Set 3 (Normal Answer) NEAX 60
    17 B Room Image Set 3 (Recovery Request) PMS 60
    17 C Room Image Set 3 (Recovery Answer) NEAX 60
    57 1 Recovery - Room Data Report PMS 90
    57 3 Recovery - Secretary Telephone PMS 90
    57 4 Recovery - Connecting Room PMS 90
    57 5 Recovery - Message Status Report PMS 90
    57 6 Recovery - Wake Up PMS 90
    19 1 Wake Up Setting NEAX ALL
    19 2 Wake Up Cancellation NEAX ALL
    19 3 Wake Up Execution Result NEAX ALL
    19 4 Wake Up Setting PMS ALL
    19 5 Wake Up Cancellation PMS ALL
    19 6 Group Announcement Setting NEAX ALL
    19 7 Group Announcement Cancellation NEAX ALL
    19 8 Group Announcement Execution Result NEAX ALL
    19 9 Group Announcement Setting PMS ALL
    19 A Group Announcement Cancellation PMS ALL
    20 1 Room Move PMS 60
    20 2 Room Swap PMS 60
    20 5 Room Copy PMS 60
    21 1 Room Data Change 60 PMS 60
    21 2 Group Formation PMS ALL
    21 3 Group Cancellation PMS ALL
    21 4 Reservation Setting PMS 60
    21 5 Reservation Cancellation PMS 60
    21 6 Guest Name Change PMS 60
    61 1 Room Data Change 90 PMS 90
    61 3 Room Status Change PMS 90
    61 4 Room Key Status Change (Model 90) PMS 90
    59 1 Direct Data Entry NEAX 90
    59 8 Direct Data Entry Negative Answer PMS 90
    FTC FC Description Source Model 
    						
    							Page D-4NDA-30115  Revision 1.0
    Function Codes Property Management System - Communication Interface
    59 9 Direct Data Entry Positive Answer PMS 90
    62 1 Guest Room Secretary Telephone PMS 90
    62 2 Guest Room Secretary Telephone NEAX 90
    62 3 Connecting Room Set PMS 90
    62 4 Connecting Room Cancel PMS 90
    FTC FC Description Source Model 
    						
    All NEC manuals Comments (0)

    Related Manuals for NEC Property Management System Communication Interface Specification