NDA-30115 Revision 1.0Page A-1 Property Management System - Communication Interface Room Status Appendix A Room Status Normally, room status information is managed in the PMS. Whatever the room status may be, the NEAX operates according to the direction provided from the PMS. The NEAX processes calls within the range shown in Figure A-1 If the room status information provided from the PMS does not coincide with the status currently stored by the NEAX, a status closest to the room’s status defined in the NEAX will be designated. Figure A-1 Room Status in the NEAX The room status information in the NEAX is processed as a validity check for maid status. Departure Day - Cleaning Va c a n t Out Departure Day Stay Out of Order Stay - Cleaning Inspection CleaningC/I C/O MDE MDI MDS RDC STC C/IC C/OC RC C/I C/O MDE MDI MDS RDCSTC C/IC C/OCRC(OLD) C/O MDE MDI MDS STC STC STC STC RDC C/O C/O MDE MDE MDS RC(NEW) RC(NEW) Check In Check Out Maid Ended Cleaning Maid Ended Inspection Maid Started Cleaning Room Data Change Status Change Check In Cancel Check Out Cancel Room Change Key
Page A-2NDA-30115 Revision 1.0 Room Status Property Management System - Communication Interface Updating Room Status Information in the NEAX The messages containing room status information, sent from the PMS, are as follows: Check In: 16-1, 16-A, 16-B, 56-1 Check Out: 16-2, 56-2 Room Change: 20-1, 56-6 Room Data Image: 17-3, 17-7, 17-B Maid Status Answer: 51-9 Check In Cancel: 56-4 Room Data Change: 61-1 Room Status Change: 61-3 Check Out Cancel: 56-5 Recovery Room Data Report: 57-1. When updating the room status from the NEAX side, the update is performed as follows: The validity of maid status messages (11-1, 11-2, 11-3, 12-1, 12-2, 12-3) is checked by the room status stored in the NEAX. After the status of the room has been updated, maid status messages are sent out to the PMS. Maid Status Answer Back System: maid status messages are sent out to the PMS. The PMS will then check the validity of the messages and provide either a positive or negative result to the NEAX. This is used in Model 90 only. For messages in Model 90, the Room Status field and the Cleaning Status field are provided so that details can be directed to the PMS. If certain hotels do not utilize maid status for their applications, the status can be designated as Vacant in the Check Out message. Clearing Room Data The NEAX will clear the room data when the PMS sets the status of the room to “Vacant (Room Status=0, Cleaning Status=3)” or “Out of Order (Room Status=0, Cleaning Status=4)”. (Note: Group Registration is cleared at the time of Check Out.) Therefore, in a hotel where the PMS does not provide maid status, the PMS must use a Check Out message to make the status of the room become “Vacant”, and thus clear the room data. Dial Steps for Maid Status A choice of three dialing patterns is available for Maid Status in the NEAX. Whichever pattern is selected, the “Inspection End” step must be included. Dial Steps Pattern 1 Pattern 2 Pattern3 Cleaning Start 1 - - Cleaning End 2 1 -
NDA-30115 Revision 1.0Page A-3 Property Management System - Communication Interface Room Status Inspection End 3 2 1 Cleaning Start, Cleaning End and Inspection End each have separate feature access codes to be dialed. Room Status and Cleaning Status When the status of the room is sent to the NEAX from the PMS, the possible Room Status and Cleaning Status values, and their meanings, are as follows: These Status Codes are displayed on the Hospitality Attendant Console and Guest Information Display services for Administration Stations. Status Codes can be changed within a range of two characters via the NEAX. Status of Check Out The status of Departure Day can be changed by providing a Room Data Change message or a Room Status Change message from the PMS to the NEAX. Room Data Setting and Clearing in the NEAX Various types of data such as Wake-Up Time and Do Not Disturb status can be set at the NEAX regardless of the status of the room. Also, a report pertaining to the particular feature status can be sent to the PMS, regardless of the status of the room. When services are set to a particular guest station, these services are not cleared until the Vacant status has entered for that room. In this way, services can be set for a vacant room, such as Room Cut Off. Also, if it is necessary to clear Room Cut Off before check in, the message to clear Room Cut Off should be sent to the NEAX at the time the status of the room, in the PMS, has become “Vacant”. When Room Status is 0 and Cleaning Status changes from 0 to 2 at the time the Check Out message has been received, Group Registration is cleared (Group Announcement or Group Wake-Up is cleared), Room Cut Off is set, and all other feature statuses are held unchanged until a Cleaning Status of 3 or 4 is entered for that room. 2 2 0 0 0 00 1 0 1 2 4Stay, Departure Day Stay, Departure Day, Cleaning in progress Out (Checked Out) Out, Cleaning in progress Out, Cleaning ended Out of Order (Cannot sell) Room 0 1 1 Cleaning 3 0 1 Status of the Room Vacant (Ready to sell) Stay (Occupied) Stay, Cleaning in progress 1 12 3Stay, Cleaning ended Stay, Inspected D DC 0 C 1 X Status V S SC * * StatusStatusCode * These have no status code.
Page A-4NDA-30115 Revision 1.0 Room Status Property Management System - Communication Interface
NDA-30115 Revision 1.0Page B-1 Property Management System - Communication Interface PMS Line Failure Printouts Appendix B PMS Line Failure Printouts Normal Text This data is printed out on the Hospitality printer when the guest room information of the NEAX is processed according to a message from the PMS. More specifically, this data is printed out when the NEAX data is forcibly changed using a message from the PMS. Figure B-1 Forcible Change Printout The following is printed out when VIP Wake-Up or Attendant Assisted Wake-Up is started. Figure B-2 Assisted Wake Up Printout Process NameGuest Room Station Number RSN: XXXXData to be Deleted CLEAR (MW) (WU XX:XX) Current TimeXX:XX *[IFIN]Wake Up Time Table B-1 Process Name List Process Name Explanation IFIN Inspection End CCKO Forcible Check Out CCLN Forcible Cleaning End CINS Forcible Inspection End RMCH Room Change [ATT ANSWER] RSN: XXXX ATT:XXX XX:XX Guest Room Station NumberAttendant Console Number (only if attendant answers)Current Time Result
Page B-2NDA-30115 Revision 1.0 PMS Line Failure Printouts Property Management System - Communication Interface Abnormal Events When the NEAX receives a message from the PMS, and the received data is abnormal or it cannot be processed by the NEAX, the message is printed out. Figure B-3 Abnormal Events Printout Abnormal Port If an external port of the NEAX is in an abnormal state, the abnormality will be printed out. Figure B-4 Abnormal Port PrintoutTable B-2 Wake Up Results Wake Up Results Explanation ATT ANSWER Attendant Console answers. ATT CALLED Attendant Console has been called. ATT CALLING: ROOM STA ANSWER While Attendant Console is calling, a guest room station has answered. ATT NO ANSWER: ROOM STA CALLED An Attendant Console has not answered, a guest room station has been called. ROOM STA BUSY A guest room station is currently on a call. Entry Error [XX-X] INPUT ERR XXXXXXXXXXXXXXXX... XX:XX Message Data Error Number:Current Time HP Task Error [EXXX] HI=XX XX XX XX XX ... XX:XX Current Time Data to be processed Ta s k E r r o r N u m b e r FTC-FC of return violation code [I/O PKG NOT READY] PORT NO = X STATUS = XX XX XX XX XX:XX Failure Type Port Number Port State Current Time
NDA-30115 Revision 1.0Page B-3 Property Management System - Communication Interface PMS Line Failure Printouts Figure B-5 Port StateTable B-3 Types of Failure Failure Type Explanation I/O PKG NOT READY The I/O package is not mounted, or it is in the make-busy state. DR OFF/TX NOT RDY The data-ready has switched off during transmission. Does not become clear-to-send during transmission. SINQ STOP/S-120 The status inquiry message has stopped. LINE SUP. TIMEOUT The monitor timer of the transmission supervisory program timed out, then restarted. RCV SEQUENCE ERR. A line control code which is invalid in reception processing has been received. DATA LINK NOT RDY Data-ready read has switched off. SINQ TO/120 DOWN System connection failure has been judged five minutes after SINQ STOP. SND SEQUENCE ERR. A line control code which is invalid in transmission process- ing has been received. DTR OFF REQUESTED Request to disconnect line from the connected system has been received. S-120 STOP (MENT) Indicates stoppage due to request to disconnect line from the connected system. LINK CLOSE (MENT) Line, package, etc. have been pulled out after requesting to disconnect line. XX XX XX XX I/O port status FIFO status scan data I/O port status scan data
Page B-4NDA-30115 Revision 1.0 PMS Line Failure Printouts Property Management System - Communication Interface Figure B-6 I/O Port Status Figure B-7 FIFO Status Scan Data Figure B-8 I/O Port Status Scan Data 0/1 : RTS signal OFF/ON 0/1 : CTS signal OFF/ON 0/1 : DR signal OFF/ON 0/1 : CI signal OFF/ON 0/1 : For transmission FIFO FULL/blank 0/1 : For reception FIFO DATA absent/present 0/1 : For transmission FIFO DATA present/absent 0/1 : -/XOFF request (FIFO HALF FULL) 0/1 : -/parity error (terminal to IOC) 0/1 : -/overrun error (terminal to IOC) 0/1 : -/framing error (terminal to IOC) 0/1 : Port (PACKAGE) absent/present 0/1 : -/off-line request (KEY) 0/1 : -/MAKE-BUSY request (KEY) 0/1 : Clock off/normal 0/1 : C-LEVEL infinite loop/normal 0/1 : -/parity error (CPU or IOC) 0/1 : -/MAKE-BUSY 0/1 : -/off-line 0/1 : Port (PACKAGE)
NDA-30115 Revision 1.0Page B-5 Property Management System - Communication Interface PMS Line Failure Printouts Transmission Failure When a message has failed to be transferred from the NEAX to the PMS, the following error message will be printed out. Figure B-9 Transmission Failure Printout Entry Error: [XX-X] TRANSFER ERR XXXXXXXXXXXXXXXX... XX:XX Message Data FTC-FC of messageCurrent Time
PMS Line Failure Printouts Property Management System - Communication Interface Page B-6NDA-30115 Revision 1.0 This Page Left Blank.