NDA-30115 Revision 1.0Page A-1 Property Management System - Communication Interface Room Status Appendix A Room Status Normally, room status information is managed in the PMS. Whatever the room status may be, the NEAX operates according to the direction provided from the PMS. The NEAX processes calls within the range shown in Figure A-1 If the room status information provided from the PMS does not coincide with the status currently stored by the NEAX, a status closest to the room’s status defined in...
Page 102
Page A-2NDA-30115 Revision 1.0 Room Status Property Management System - Communication Interface Updating Room Status Information in the NEAX The messages containing room status information, sent from the PMS, are as follows: Check In: 16-1, 16-A, 16-B, 56-1 Check Out: 16-2, 56-2 Room Change: 20-1, 56-6 Room Data Image: 17-3, 17-7, 17-B Maid Status Answer: 51-9 Check In Cancel: 56-4 Room Data Change: 61-1 Room Status Change: 61-3 Check Out Cancel: 56-5 Recovery Room Data Report: 57-1. When updating the...
Page 103
NDA-30115 Revision 1.0Page A-3 Property Management System - Communication Interface Room Status Inspection End 3 2 1 Cleaning Start, Cleaning End and Inspection End each have separate feature access codes to be dialed. Room Status and Cleaning Status When the status of the room is sent to the NEAX from the PMS, the possible Room Status and Cleaning Status values, and their meanings, are as follows: These Status Codes are displayed on the Hospitality Attendant Console and Guest Information Display...
Page 104
Page A-4NDA-30115 Revision 1.0 Room Status Property Management System - Communication Interface
Page 105
NDA-30115 Revision 1.0Page B-1 Property Management System - Communication Interface PMS Line Failure Printouts Appendix B PMS Line Failure Printouts Normal Text This data is printed out on the Hospitality printer when the guest room information of the NEAX is processed according to a message from the PMS. More specifically, this data is printed out when the NEAX data is forcibly changed using a message from the PMS. Figure B-1 Forcible Change Printout The following is printed out when VIP Wake-Up...
Page 106
Page B-2NDA-30115 Revision 1.0 PMS Line Failure Printouts Property Management System - Communication Interface Abnormal Events When the NEAX receives a message from the PMS, and the received data is abnormal or it cannot be processed by the NEAX, the message is printed out. Figure B-3 Abnormal Events Printout Abnormal Port If an external port of the NEAX is in an abnormal state, the abnormality will be printed out. Figure B-4 Abnormal Port PrintoutTable B-2 Wake Up Results Wake Up Results...
Page 107
NDA-30115 Revision 1.0Page B-3 Property Management System - Communication Interface PMS Line Failure Printouts Figure B-5 Port StateTable B-3 Types of Failure Failure Type Explanation I/O PKG NOT READY The I/O package is not mounted, or it is in the make-busy state. DR OFF/TX NOT RDY The data-ready has switched off during transmission. Does not become clear-to-send during transmission. SINQ STOP/S-120 The status inquiry message has stopped. LINE SUP. TIMEOUT The monitor timer of the transmission...
Page 108
Page B-4NDA-30115 Revision 1.0 PMS Line Failure Printouts Property Management System - Communication Interface Figure B-6 I/O Port Status Figure B-7 FIFO Status Scan Data Figure B-8 I/O Port Status Scan Data 0/1 : RTS signal OFF/ON 0/1 : CTS signal OFF/ON 0/1 : DR signal OFF/ON 0/1 : CI signal OFF/ON 0/1 : For transmission FIFO FULL/blank 0/1 : For reception FIFO DATA absent/present 0/1 : For transmission FIFO DATA present/absent 0/1 : -/XOFF request (FIFO HALF FULL) 0/1 : -/parity error (terminal...
Page 109
NDA-30115 Revision 1.0Page B-5 Property Management System - Communication Interface PMS Line Failure Printouts Transmission Failure When a message has failed to be transferred from the NEAX to the PMS, the following error message will be printed out. Figure B-9 Transmission Failure Printout Entry Error: [XX-X] TRANSFER ERR XXXXXXXXXXXXXXXX... XX:XX Message Data FTC-FC of messageCurrent Time
Page 110
PMS Line Failure Printouts Property Management System - Communication Interface Page B-6NDA-30115 Revision 1.0 This Page Left Blank.