Page 81
NDA-30115 Revision 1.0Page 71 Property Management System - Communication Interface Message Formats Extension Assignment Report Figure 4-46 Extension Assignment Report Message fields are: Extension -- Extension number. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters. Def -- Defines the extension to be either an administration extension or a guest extension. Codes are: 0 -- Administration 1 -- Guest Class -- The...
Page 82
Page 72NDA-30115 Revision 1.0 Message Formats Property Management System - Communication Interface Room Recovery (Model 60) These messages are used by the PMS to update the database in the Model 60 version of the NEAX. First a Recovery Start Report (70-3) is sent. Then, one or more sets of Room Image messages are sent. Finally, a Recovery End Report (70- 4) is sent. The messages are grouped into a set of four messages. Within each set of four messages the format of the messages is identical, except...
Page 83
NDA-30115 Revision 1.0Page 73 Property Management System - Communication Interface Message Formats Room Image Set 1 Figure 4-47 Room Image Set 1 The message fields are: FC -- Function Codes that use this message format are: (FTC-FC) 17-1 -- Room Image Set 1 (Normal Request from PMS) 17-2 -- Room Image Set 1 (Normal Answer from NEAX) 17-3 -- Room Image Set 1 (Recovery Request from PMS) 17-4 -- Room Image Set 1 (Recovery Answer from NEAX) Extension -- Extension number. If the extension number is...
Page 84
Page 74NDA-30115 Revision 1.0 Message Formats Property Management System - Communication Interface Room Image Set 2 Figure 4-48 Room Image Set 2 The message fields are: FC -- Function Codes that use this message format are: (FTC-FC) 17-5 -- Room Image Set 2 (Normal Request from PMS) 17-6 -- Room Image Set 2 (Normal Answer from NEAX) 17-7 -- Room Image Set 2 (Recovery Request from PMS) 17-8 -- Room Image Set 2 (Recovery Answer from NEAX) Extension -- Extension number. If the extension number is...
Page 85
NDA-30115 Revision 1.0Page 75 Property Management System - Communication Interface Message Formats Stay -- Room stay. The possible values are listed below: Reserve -- Reserve flag. Possible values are: 0 -- Room is not reserved 1 -- Room is reserved. Language -- Language category for the guest. The possible values are: 0 -- Not specified 1 -- Japanese 2 -- English 3 -- German 4 -- French 5 -- Spanish 6 -- Chinese 7 -- Russian. Cleaning Status -- The possible values are: 1 -- Cleaning...
Page 86
Page 76NDA-30115 Revision 1.0 Message Formats Property Management System - Communication Interface Room Image Set 3 Figure 4-49 Room Image Set 3 The message fields are: FC -- Function Codes that use this message format are: (FTC-FC) 17-9 -- Room Image Set 3 (Normal Request from PMS) 17-A -- Room Image Set 3 (Normal Answer from NEAX) 17-B -- Room Image Set 3 (Recovery Request from PMS) 17-C -- Room Image Set 3 (Recovery Answer from NEAX) Extension -- Extension number. If the extension number is...
Page 87
NDA-30115 Revision 1.0Page 77 Property Management System - Communication Interface Message Formats Stay -- Room stay. The possible values are listed below: Reserve -- Reserve flag. Possible values are: 0 -- Room is not reserved 1 -- Room is reserved. Language -- Language category for the guest. The possible values are: 0 -- Not specified 1 -- Japanese 2 -- English 3 -- German 4 -- French 5 -- Spanish 6 -- Chinese 7 -- Russian. Cleaning Status -- The possible values are: 1 -- Cleaning...
Page 88
Page 78NDA-30115 Revision 1.0 Message Formats Property Management System - Communication Interface Room Recovery (Model 90) These messages are only used by the Model 90. When the PMS receives a Nop Test Recover Answer (70-2) message, it sends one Room Data Report message for each room. Prior to sending any recovery messages, however, a Recovery Start Report (70-3) must first be sent. Recovery is concluded by sending a Recovery End Report (70-4). The Room Recovery messages use the following Function...
Page 89
NDA-30115 Revision 1.0Page 79 Property Management System - Communication Interface Message Formats Cleaning Status -- Cleaning status. The possible combinations with room status are listed below: Key -- Room key status: 0 -- Key is in the key rack. 1 -- Key is not in the key rack. VIP -- VIP category: 0 -- Guest is not a VIP. 1 -- Guest is a VIP. Language -- Language category for the guest. The possible values are: 0 -- Not specified 1 -- Japanese 2 -- English 3 -- German 4 -- French 5 --...
Page 90
Page 80NDA-30115 Revision 1.0 Message Formats Property Management System - Communication Interface Guest Room Secretary Telephone Figure 4-51 Guest Room Secretary Telephone The message fields are: Boss -- Extension number of the boss. If the extension number is less than six digits, left justify the number and fill the remaining bytes with space (20H) characters. Secty -- Extension number of the secretary. The secretary’s extension is now associated with the boss’s extension. If the extension...