ND-46551 (E) CHAPTER 3 Page 139 Revision 2.0 NAP-200-008 Sheet 13/13 Switch Setting of Circuit Card 7. PN-8LCS (LC) (1) Locations of Lamps, Switches and Connectors Figure 008-6 PN-8LCS (LC) Card (2) Lamp Indications (3) Switch Settings This card has no switches. Table 008-12 PN-8LCS (LC) Card Lamp Indications LAMP NAME COLOR FUNCTION BL0 - 7 Red• Remains lit when the corresponding circuit is in use. • Flashes at 60 IPM when the corresponding circuit is in the make-busy state or the system data for...
Page 152
CHAPTER 3 ND-46551 (E) Pag e 1 40 Revision 2.0 NAP-200-009 Sheet 1/3 Mounting of Circuit Cards 1. MOUNTING PROCEDURE (1) For testing, turn on “SW1” switch on the PZ-PW86 Card. Make sure that “ON” lamp (Green) is lit. (2) Turn off “SW1” switch. Figure 009-1 PZ-PW86(C) Card Lamp Indication PZ-PW86 ON OFFSW1 SWITCH ON LAMP (GREEN) MN MJ ON
Page 153
ND -4 6551 ( E) CHAPTER 3 NAP-200-0 09 CARD FRONT SIDE WR IST STRAP TO FRA ME GROUND CONNECTION CARD CONT ACT S IDE
Page 155
ND-46551 (E) CHAPTER 3 Page 143 Revision 2.0 NAP-200-010 Sheet 1/7 System Initialization and System Data Entr y 1. SYSTEM INITIALIZATION • There are two methods for System Initialization. The first method is to Clear All Data, except LEN0000 as a CAT terminal, and then program the System Data. The second method is to use the Resident System Program, which causes the system to configure itself automatically to the default settings, wherever the line/trunk cards are installed. Refer to the System Data...
Page 156
CHAPTER 3 ND-46551 (E) Pag e 1 44 Revision 2.0 NAP-200-010 Sheet 2/7 System Initialization and System Data Entr y 2. SYSTEM DATA ENTRY • There are two methods for data entry, both of which employ a Customer Administration Terminal (CAT) or a Maintenance Administration Terminal (MAT). 2.1 CAT Any Multiline Terminal can be assigned as a CAT terminal through programming. The Multiline Terminal can still be used as a regular telephone when it is not in CAT mode. If the system is initialized by “C”...
Page 157
ND-46551 (E) CHAPTER 3 Page 145 Revision 2.0 NAP-200-010 Sheet 3/7 System Initialization and System Data Entr y To reset CAT mode: While “COMMAND = -” is displayed on the LCD: (1) Lift the handset (off hook) - SPKR lamp turns off. (2) Restore the handset (on hook) - CNF, ANS lamps turn off. - LCD returns to clock. 2.2 MAT In addition to the CAT mode programming, the MAT can also be used in the MAT mode. Refer to the MAT Oper- ation Guide and the Command Manual. 2.3 Feature Programming This section...
Page 158
CHAPTER 3 ND-46551 (E) Pag e 1 46 Revision 2.0 NAP-200-010 Sheet 4/7 System Initialization and System Data Entr y (1) Programming Procedure for Music On Hold For providing Hold Tone Source on the MP card: For providing External Hold Tone Source through the MP card: DESCRIPTION DATA Select the music to be provided. (1) 183 (2) 0: Nocturne 1 : Minuet Define the type of call to be provided with Hold Tone on the MP card. Note:When using the MP card, set the JP1 switch to UP (Internal Hold Tone Source)..Y =...
Page 159
ND-46551 (E) CHAPTER 3 Page 147 Revision 2.0 NAP-200-010 Sheet 5/7 System Initialization and System Data Entr y For providing External Hold Tone Source through MP card: • External Hold Tone Source provided locally For connecting the External Hold Tone Source, plug the cable into JACK on the MP card. Set the switches on the MP card as follows: For providing Hold Tone Source on the MP card: Set the JP1 switch to UP. PBX MP CARD JACKEXTERNAL HOLD TONE SOURCE JP1 VR MP CARD JP1: INTERNAL/EXTERNAL HOLD TONE...
Page 160
CHAPTER 3 ND-46551 (E) Pag e 1 48 Revision 2.0 NAP-200-010 Sheet 6/7 System Initialization and System Data Entr y (2) Programming Procedure for Push button Calling DESCRIPTION DATA Assign the Card Number of internal PB Receiver to the LEN No. 0124. Note:When using the internal PB Receiver on the MP card, assign the Card No. E200- E203 to the LEN No. 0124. If resident load is used, PB Receiver ports (E200-LENS 0124) are automatically as- signed.(1) LEN: 0124 (2) E200-E203 (PB Receiver No.) Assign the...