ND-46551 (E) CHAPTER 3
Page 129
Revision 2.0
NAP-200-008
Sheet 3/13
Switch Setting of Circuit Card
(3) Switch Setting
Table 008-4  PN-CP03 (MP) Card Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SW3 (Rotary SW)
0 - FOn Line (Call processing is in progress)
2Off Line (Call processing is stopped)
• I/O port : Depending on 
CM40 YY=08
3Off Line (Call processing is stopped)
• I/O port : 1200bps (Fixed)
B For clearing the office data
C For setting the resident system program
1, 4 -...

Page 142

CHAPTER 3 ND-46551 (E)
Pag e 1 30
Revision 2.0
NAP-200-008
Sheet 4/13
Switch Setting of Circuit Card
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Note :Set the groove on the switch knob to the desired switch position.
Table 008-4 PN-CP03 (MP) Card Switch Settings (Continued)
SWITCH NAMESWITCH...

Page 143

ND-46551 (E) CHAPTER 3
Page 131
Revision 2.0
NAP-200-008
Sheet 5/13
Switch Setting of Circuit Card
CAUTION:When the operating power is being supplied to this circuit card, do not plug/unplug this circuit
card into/from its mounting slot.
3. PZ-PW86 (PWR)
(1) Locations of Lamps, Switches, and Connectors
Figure 008-2  PZ-PW86 (PWR) Card
FRONT VIEW BATT2MN MJ
ONBATTERY
SIDE VIEW GND
–27V FG
OFFON
240VAC 100/120VAC 2ON
2
1 ON
SW301 START
SIG
1
SW1
BATT1
AC INPUTMODE
SW102 

Page 144

CHAPTER 3 ND-46551 (E)
Pag e 1 32
Revision 2.0
NAP-200-008
Sheet 6/13
Switch Setting of Circuit Card
(2) Lamp Indications
Table 008-5  PZ-PW86(C) (PWR) Card Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major fault.
MN Orange Lights upon occurrence of a minor fault.
ON Green Remains lit while the power is on. 

Page 145

ND-46551 (E) CHAPTER 3
Page 133
Revision 2.0
NAP-200-008
Sheet 7/13
Switch Setting of Circuit Card
(3) Switch Settings
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION col-
umn indicate the standard setting of the switch. When the switch is not set as shown by the figure and
, the setting of the switch varies with the system concerned.
Table 008-6  PZ-PW86(C) (PWR) Card Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
SW101 (Piano Key SW)
1...

Page 146

CHAPTER 3 ND-46551 (E)
Pag e 1 34
Revision 2.0
NAP-200-008
Sheet 8/13
Switch Setting of Circuit Card
4. PZ-PW86(D) (PWR)
(4) Locations of Lamps, Switches and Connectors
Figure 008-3  PZ-PW86(D) (PWR) Card
(2) Lamp Indications
Table 008-7  PZ-PW86(D) (PWR) Card Lamp Indications
LAMP NAME COLOR FUNCTION
MJ Red Lights upon occurrence of a major trouble
MN Orange Lights upon occurrence of a minor trouble
ON Green Remains lit while the operating power is being supplied
FRONT VIEWBATT2 MN MJ
ON
BATTERY
SIDE...

Page 147

ND-46551 (E) CHAPTER 3
Page 135
Revision 2.0
NAP-200-008
Sheet 9/13
Switch Setting of Circuit Card
(3) Switch Settings
The figure in the SWITCH NAME column and the position in    in the SETTING POSITION column
indicate the standard setting of the switch. When the switch is not set as shown by the figure and   ,
the setting of the switch varies with the system concerned.
Table 008-8  PZ-PW86(D) (PWR) Card Switch Settings
SWITCH NAMESWITCH 
NUMBERSETTING 
POSITIONFUNCTION CHECK
MODE
1Always set to OFF...

Page 148

CHAPTER 3 ND-46551 (E)
Pag e 1 36
Revision 2.0
NAP-200-008
Sheet 10/13
Switch Setting of Circuit Card
5. PN-PW00 (EXTPWR)
(4) Locations of Lamps, Switches and Connectors
Figure 008-4  PN-PW00 (EXTPWR) Card
(2) Lamp Indications
Table 008-9  PN-PW00 (EXTPWR) Card Lamp Indications 
LAMP NAME COLOR FUNCTION
RUN Green Remains lit while –48 V power is being supplied
RUN
MB
CONN 

Page 149

ND-46551 (E) CHAPTER 3
Page 137
Revision 2.0
NAP-200-008
Sheet 11/13
Switch Setting of Circuit Card
The figure in the SWITCH NAME column and the position in   in the SETTING POSITION column indicate
the standard setting of the switch. When the switch is not set as shown by the figure and  , the setting of the
switch varies with the system concerned.
Note :When the power is on, flip the MB switch to ON (UP position) before plugging/unplugging the circuit card.Table 008-10  PN-PW00 (EXTPWR) Card Switch...

Page 150

CHAPTER 3 ND-46551 (E)
Pag e 1 38
Revision 2.0
NAP-200-008
Sheet 12/13
Switch Setting of Circuit Card
6. PN-8DLCJ/8DLCP (DLC)
(1) Locations of Lamps, Switches and Connectors
Figure 008-5  PN-8DLCJ/8DLCP (DLC) Card
(2) Lamp Indications
• Switch Settings
This card has no switches.
Table 008-11   PN-8DLCJ8DLCP (DLC) Card Lamp Indications
LAMP NAME COLOR FUNCTION
BL0 - 7 Red• Remains lit when the corresponding circuit is in use.
• Flashes at 60 IPM when the corresponding circuit is in the make-busy state or...