NEC Neax2000 Ivs Acd Mis System Manual
Here you can view all the pages of manual NEC Neax2000 Ivs Acd Mis System Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 61
GENERAL DESCRIPTION NDA-30094 CHAPTER 1 Page 53 Revision 1 3.6.8 System Date Format This function determines the way that the date is formatted--both on the screens and printed out in reports. Three options are available: dd/mm/yyyy mm/dd/yyyy yyyy/mm/dd
Page 62
CHAPTER 1 NDA-30094 Page 54 Revision 1 GENERAL DESCRIPTION 3.7 Alarm Configuration Several of the parameters appearing in the Statistics Monitor mode are associated with dual operational limits which are programmed within Alarm Configuration as part of the overall administration of the system. If either limit is equaled or exceeded, visual and audible indications will be given to warn supervisory staff, who can then take appropriate action. Once the condition returns to normal, the alarm function is...
Page 63
GENERAL DESCRIPTION NDA-30094 CHAPTER 1 Page 55 Revision 1 Average Answer, Average Talk, Average Available, and Longest Waiting Call (defined in Section 3.1) are di- rect time measurements (in minutes and seconds) related to call handling. Their settings are specified in ascend- ing order. 3.7.2 Agent Statistics Threshold Similar limits are set for agent parameters. This includes the low and high alarms for Average Answer and Av- erage Talk statistics on a per-ACD-group basis. Direct time measurements...
Page 64
CHAPTER 1 NDA-30094 Page 56 Revision 1 GENERAL DESCRIPTION 3.8 Exit The Exit function completely shuts down ACD-MIS and returns you to UNIX prompt. CAUTION: No call data from the PABX can be processed when ACD-MIS is shut down. To exit from ACD-MIS, go to Exit on the menu.
Page 65
GENERAL DESCRIPTION NDA-30094 CHAPTER 1 Page 57 Revision 1 4. MULTIPLE SUPERVISOR TERMINALS 4.1 General One UAP Computer (See Figure 1-2) can supports multiple ACD-MIS applications and multiple users can login into each ACD-MIS applications. Since the ACD-MIS user is an UNIX user, the user can connect via RS-232 link or by TCP/IP Ethernet. The terminal type is ANSI terminal. The first user to log in is called the Master. The Master is allowed to use all the commands in the ACD-MIS menu. Other users are...
Page 66
CHAPTER 1 NDA-30094 Page 58 Revision 1 GENERAL DESCRIPTION Figure 1-2 Connection of Multiple MIS Terminals AP01 card NEAX2000 IVS Dterm Series III Dterm Series III Master Ethernet Sub-MasterSub-Master Dterm Series III Dterm Series III Master ACDMIS 1ACDMIS 2 NEAX2000 IVS
Page 67
INSTALLATION PROCEDURES NDA-30094 CHAPTER 2 Page 59 Revision 1 CHAPTER 2 INSTALLATION PROCEDURES 1. INTRODUCTION Installation of the NEAX2000 IVS ACD-MIS system involves a number of actions, which are summarized in this chapter. In addition, you may need to refer to: Chapter 3, Operating Instructions Specific NEAX2000 IVS manuals SCO User’s Guide Before installing the ACD-MIS, the following requirements must be met: A personal computer with SCO must be connected to Ethernet. The NEAX2000 IVS must...
Page 68
CHAPTER 2 NDA-30094 Page 60 Revision 1 INSTALLATION PROCEDURES 2. SYSTEM HARDWARE SPECIFICATION 2.1 External Display Units In an ACD environment, an end-user can indicate (to agents) the total number of calls, and the longest period of time that calls have been in an ACD group queue waiting to be answered. With the ACD-MIS software, ex- ternal display units/wallboards may be interfaced with the personal computer (which provided the MIS capabil- ity). This wallboard may be centrally located among the...
Page 69
INSTALLATION PROCEDURES NDA-30094 CHAPTER 2 Page 61 Revision 1 3. INSTALLATION PROCEDURES 3.1 Select or add destination link Before adding ACD-MIS installation link, go to APM system configuration menu. Check the existing destina- tion link or add a new destination link for the ACD-MIS. Make sure the destination link port number is set to 0 so that the destination link can be shared with other application and can run TSAPI application. Refer to APM Operation manual for detail of adding a destination...
Page 70
CHAPTER 2 NDA-30094 Page 62 Revision 1 INSTALLATION PROCEDURES Enter 1 and hit return key. The screen shows: Figure 2-1 APM Installation Script (Cont) Enter y and hit return key. The screen shows: Figure 2-1 APM Installation Script (Cont) Enter y and hit return key. The screen shows: Figure 2-1 APM Installation Script (Cont) User Login Name acdmis1 and User ID 4201 has been entered Do you want to continue with the installation? (y/n) ACD-MIS Installation Procedure for SCO UNIX...