OPERATING PROCEDURES
NDA-30094 CHAPTER 3
Page 123
Revision 1 8.4 Audible Alarm Period
The alarm warning tone associated with the high value of the Statistics Monitor - System and Group Statistics
Waiting Longest parameter can be set to be repeated every 5, 10, 20, 30, 60 or 90 seconds or disabled altogether,
by this function.
Any adjustment made has an immediate effect, even if the warning tone is currently being produced.
Step 1. From the Alarm Configuration submenu, press 4.  The Audible Alarm Period...

Page 132

CHAPTER 3 NDA-30094
Page 124
Revision 1
OPERATING PROCEDURES
9. SYSTEM EXIT
Step 1. Check for current printing of any reports.
Step 2. From the Main Menu, select Item 3 - System Maintenance.  The SYSTEM MAINTENANCE sub-
menu will display.
Step 3. Select Item 4 - OAI Connection.  
The 
Disconnect from PBX (y/n) message will be displayed.
Step 4. Type 
y.  The Checking Communications Status.  Please wait message will be displayed.
Wait for the system to return to the sub menu then ensure connection status...

Page 133

CUSTOMER SPECIFICATIONS
NDA-30094 CHAPTER 4
Page 125
Revision 1
CHAPTER 4 CUSTOMER SPECIFICATIONS
1. SYSTEM CONFIGURATION
1.1 Group Configuration
A maximum of 16 ACD groups can be specified.
Group name can be a maximum of 11 alphanumeric characters.
The nominated pilot is usually a phantom extension.  It can be a physical extension, but it must not receive
direct calls.
Table 4-1  ACD Group Configuration Table
ACD group Indial No.
No. Name Prefix Pilot ext.
01
02
03
04
05
06
07
08
09
10
11
12
13
14...

Page 134

CHAPTER 4 NDA-30094
Page 126
Revision 1
CUSTOMER SPECIFICATIONS
1.2 Agent Configuration
A maximum of  60 extensions can be assigned per ACD group.
Extensions (including the pilot number) can be entered in any order.
Tenant No. must be the value set for the ACD group within the PABX.
Where preferred, the entry for Agent Name can be other than a surname (e.g., Agent 1).  Each entry must
be a maximum of 11 characters, including spaces.
PHOTOCOPY AS REQUIRED:
 Agent Configuration Table Table 4-2  Agent...

Page 135

CUSTOMER SPECIFICATIONS
NDA-30094 CHAPTER 4
Page 127
Revision 1
TENANT NO.:
...............................GROUP NAME: ......................................
GROUP No.: .......................................
AGENT ID 
CODEAGENT (SUR)NAMEAGENT
INITIAL
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25 

Page 136

CHAPTER 4 NDA-30094
Page 128
Revision 1
CUSTOMER SPECIFICATIONS
1.3 Report Time Values
Terms are defined as follows:
Time to Answer refers to G.O.S. calculation.
Abandoned Ignore Time is the minimum required waiting time before disconnection for the call to be
considered as abandoned.
Answer Time, Abandon Time and Duration Time refer to the Calls Within parameters of the Calls Wait-
ing, Calls Abandoned, and Call Duration reports, respectively.
Ensure that the values specified for Answer Time,...

Page 137

CUSTOMER SPECIFICATIONS
NDA-30094 CHAPTER 4
Page 129
Revision 1 1.4 Storage Intervals
Table 4-4  Storage Intervals
SEGMENT INCREMENT SEGMENT INCREMENT
0000 - 0059 10 15 20 30 60 1200 - 1259 10 15 20 30 60
0100 - 0159 10 15 20 30 60 1300 - 1359 10 15 20 30 60
0200 - 0259 10 15 20 30 60 1400 - 1459 10 15 20 30 60
0300 - 0359 10 15 20 30 60 1500 - 1559 10 15 20 30 60
0400 - 0459 10 15 20 30 60 1600 - 1659 10 15 20 30 60
0500 - 0559 10 15 20 30 60 1700 - 1759 10 15 20 30 60
0600 - 0659 10 15 20 30 60 1800 -...

Page 138

CHAPTER 4 NDA-30094
Page 130
Revision 1
CUSTOMER SPECIFICATIONS
1.5 External Display Unit
1.5.1 EDU Port Selection
Only one EDU can be assigned to each port.
The “None“ option can be selected to disable any particular port.
Note: Consult the UNIX System Administrator for the /dev name of the EDU ports.
1.5.2 External Display Format
Any format can be assigned to any EDU.
The same format can be selected for display on all EDUs.
If the  “Not used” option is assigned to any EDU, it will remain blank....

Page 139

CUSTOMER SPECIFICATIONS
NDA-30094 CHAPTER 4
Page 131
Revision 1
2. STATISTICS REPORTING
2.1 Report Configuration
A maximum of 20 Report Configurations can be assigned.
A maximum of 20 (alphanumeric) characters can be entered for Report Name.
Observe the applications of Class for various Report Types as described in Chapter 1.
Table 4-7  Report Configuration
REPORT NAME: 
REPORT TYPE: Group Break and Work Agent Break and Work
Calls Waiting Calls Abandoned Call Duration Traffic Analysis
Group Workload...

Page 140

CHAPTER 4 NDA-30094
Page 132
Revision 1
CUSTOMER SPECIFICATIONS
PHOTOCOPY AS REQUIRED:
Report Configuration 
REPORT NAME: 
REPORT TYPE: Group Break and Work Agent Break and Work
Calls Waiting Calls Abandoned Call Duration Traffic Analysis
Group Workload Group Performance Agent Performance Agent Demand
CLASS : Full All Selected
DATE TYPE
Today Yesterday This Week Last Week
This Month Last Month This Year Last Year For Date Date Range
BREAKDOWN
By Period Hourly Daily
Monthly Weekday Total