Page 641

NDA-24307 CHAPTER 8
Page 613
Issue 1
CBCN: Control of Broadcasting for NDM
CBCN:Control of Broadcasting for NDM
1. Functional Outline
This command specifies the destination of NDM data broadcast from the NCN. This command is available
only at the NCN (Network Control Node).
2. Parameters
Input data
TYPE:  ALL (All the Nodes)/ONE (One designated Node)
FPC:  FPC of the designated Node 
Note
Interval:  Broadcasting Interval
Note:This parameter appears when one node is selected. 

Page 642

CHAPTER 8 NDA-24307
Page 614
Issue 1
CCSE: Change of Common Signaling Channel Equipment
CCSE:Change of Common Signaling Channel Equipment
1. Functional Outline
This command is used to set/reset the make busy state of CCH circuit card.
2. Parameters
CCH LENS: Line Equipment Number of CCH circuit card [5 digits]
MG=XX, UNIT=X, GROUP=XX
LINK: Link Status [0-2]
0=Link Open
1=Link Close
2=Not Available
MB: Make Busy Information [0-2]
0=Make Idle
1=Make Busy
2=Not Available
Note:This command cannot be used for...

Page 643

NDA-24307 CHAPTER 8
Page 615
Issue 1
CDBU: Change of Dch Backup
CDBU:Change of Dch Backup
1. Functional Outline
This command is used to execute the D-channel route changeover, associated with the D-CHANNEL BACK-
UP-PRI feature (for AT&T/NT/N-ISDN2).
2. Parameters
Input data
MG: Module Group Number [00-07] 
Note
CNT: Number of Dch Backup Route [1-32] Note
Buttons
Get: Click to get information on the Dch Routes.
Change: Click to execute the Dch route changeover.
Stop: Click to cancel the Dch route...

Page 644

CHAPTER 8 NDA-24307
Page 616
Issue 1
CMOD: Change of System Mode
CMOD:Change of System Mode
1. Functional Outline
This command is used to execute ACT/ST-BY change of the processor (CPU) / TSW and display the status of
CPU/CLK/TSW/PLO.
2. Parameters
Input data
TYPE: Type of Process (1,2)
1/2=Change Operating Mode/Make Busy of TSW
DEVICE: Device to be changed (1,2)
Note 1
1=CPUNote 2
2=TSW
SW: Type of Switch
Note 3
1=TSW(fixed)
SYSTEM: System of Switch (0,1)
Note 3
0/1=System 0/System 1
Note 1:This...

Page 645

NDA-24307 CHAPTER 8
Page 617
Issue 1
CMODI: Change of System Mode for ISW
CMODI:Change of System Mode for ISW
1. Functional Outline
This command is used to execute ACT/ST-BY change of the CPU/TSW and display the status of CPU/TSW/
PLO. To use this command, the MAT must be connected to ISW.
2. Parameters
Input data
FPC: FPC of designated Node
Note:When TSW changeover is executed, be sure to assign FPC of ISW.
TYPE SELECT: 1=ACT/ST-BY change of CPU/TSW
2=MB Control of TSW
[When TYPE 1 is selected]
DEVICE:...

Page 646

CHAPTER 8 NDA-24307
Page 618
Issue 1
CMWL: Control Message Waiting Lamp
CMWL:Control Message Waiting Lamp
1. Functional Outline
This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the
station. If the station is a D
term, this command can also control Message Waiting Display on the Dterm.
2. Parameters
Input Data
TYPE: Type of Input (1,2)
1/2=Designation by Station Number/Designation by LEN
TN:
Note 1
STN: Maximum 5 digits for Business system, and 6 digits for...

Page 647

NDA-24307 CHAPTER 8
Page 619
Issue 1
CMWL_T: Control Message Waiting Lamps - Telephone Number
CMWL_T:Control Message Waiting Lamps - Telephone Number
1. Functional Outline
This command is used to control/display the Message Waiting Lamp’s ON/OFF status, by using Telephone
Numbers. When the station is a D
term, this command can also be used to control the Message Waiting Lamp
Display. This command is available at NCN (for Fusion network) only. 
Note
Note:
This command is available for PBX program...

Page 648

CHAPTER 8 NDA-24307
Page 620
Issue 1
CPRS: Controlled Alternate PRSCs
CPRS:Controlled Alternate PRSCs
1. Functional Outline
This command is necessary for the Controlled Alternate PRSCs function. It either selects the class used be-
tween two priority restriction classes (Normal or Urgent), or indicates the class used. This command is allowed
only when bit1 of SYS 1, INDEX 59 is “1” (Controlled Alternate PRSCs in service).
2. Parameters
N/U: Priority Restriction Class [N/U]
N=Normal
U=Urgent 

Page 649

NDA-24307 CHAPTER 8
Page 621
Issue 1
CSCL: Continuous Change of Station Class
CSCL:Continuous Change of Station Class
1. Functional Outline
This command can change the station class information (RSC, SFC) continuously by designating the
consecutive range of the station numbers.
2. Parameters
Input data
TN: Tenant Number
STN(START): First Station Number [0-9, #, * (Max. 6 digits)] 
Note 1
STN(END): Last Station Number [0-9, #, * (Max. 6 digits)] Note 1
TEC(OLD): Telephone Equipment Class before change...

Page 650

CHAPTER 8 NDA-24307
Page 622
Issue 1
CSTN: Continuous Change of Station Number
CSTN:Continuous Change of Station Number
1. Functional Outline
This command can change a consecutive range of physical station numbers.
2. Parameters
Input data
TN: Tenant Number 
OLD STN(START): First Station Number before change [0-9, #, * (Max. 6 digits)] 
Note
OLD STN(END): Last Station Number before change [0-9, #, * (Max. 6 digits)] Note
NEW STN(START): First Station Number after change [0-9, #, * (Max. 6 digits)] Note...