NEC Neax 2400 Ipx System Operations And Maintenance Manual
Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 641
NDA-24307 CHAPTER 8 Page 613 Issue 1 CBCN: Control of Broadcasting for NDM CBCN:Control of Broadcasting for NDM 1. Functional Outline This command specifies the destination of NDM data broadcast from the NCN. This command is available only at the NCN (Network Control Node). 2. Parameters Input data TYPE: ALL (All the Nodes)/ONE (One designated Node) FPC: FPC of the designated Node Note Interval: Broadcasting Interval Note:This parameter appears when one node is selected.
Page 642
CHAPTER 8 NDA-24307 Page 614 Issue 1 CCSE: Change of Common Signaling Channel Equipment CCSE:Change of Common Signaling Channel Equipment 1. Functional Outline This command is used to set/reset the make busy state of CCH circuit card. 2. Parameters CCH LENS: Line Equipment Number of CCH circuit card [5 digits] MG=XX, UNIT=X, GROUP=XX LINK: Link Status [0-2] 0=Link Open 1=Link Close 2=Not Available MB: Make Busy Information [0-2] 0=Make Idle 1=Make Busy 2=Not Available Note:This command cannot be used for...
Page 643
NDA-24307 CHAPTER 8 Page 615 Issue 1 CDBU: Change of Dch Backup CDBU:Change of Dch Backup 1. Functional Outline This command is used to execute the D-channel route changeover, associated with the D-CHANNEL BACK- UP-PRI feature (for AT&T/NT/N-ISDN2). 2. Parameters Input data MG: Module Group Number [00-07] Note CNT: Number of Dch Backup Route [1-32] Note Buttons Get: Click to get information on the Dch Routes. Change: Click to execute the Dch route changeover. Stop: Click to cancel the Dch route...
Page 644
CHAPTER 8 NDA-24307 Page 616 Issue 1 CMOD: Change of System Mode CMOD:Change of System Mode 1. Functional Outline This command is used to execute ACT/ST-BY change of the processor (CPU) / TSW and display the status of CPU/CLK/TSW/PLO. 2. Parameters Input data TYPE: Type of Process (1,2) 1/2=Change Operating Mode/Make Busy of TSW DEVICE: Device to be changed (1,2) Note 1 1=CPUNote 2 2=TSW SW: Type of Switch Note 3 1=TSW(fixed) SYSTEM: System of Switch (0,1) Note 3 0/1=System 0/System 1 Note 1:This...
Page 645
NDA-24307 CHAPTER 8 Page 617 Issue 1 CMODI: Change of System Mode for ISW CMODI:Change of System Mode for ISW 1. Functional Outline This command is used to execute ACT/ST-BY change of the CPU/TSW and display the status of CPU/TSW/ PLO. To use this command, the MAT must be connected to ISW. 2. Parameters Input data FPC: FPC of designated Node Note:When TSW changeover is executed, be sure to assign FPC of ISW. TYPE SELECT: 1=ACT/ST-BY change of CPU/TSW 2=MB Control of TSW [When TYPE 1 is selected] DEVICE:...
Page 646
CHAPTER 8 NDA-24307 Page 618 Issue 1 CMWL: Control Message Waiting Lamp CMWL:Control Message Waiting Lamp 1. Functional Outline This command indicates ON/OFF status and controls the Message Waiting Lamp ON/OFF (MW Lamp) at the station. If the station is a D term, this command can also control Message Waiting Display on the Dterm. 2. Parameters Input Data TYPE: Type of Input (1,2) 1/2=Designation by Station Number/Designation by LEN TN: Note 1 STN: Maximum 5 digits for Business system, and 6 digits for...
Page 647
NDA-24307 CHAPTER 8 Page 619 Issue 1 CMWL_T: Control Message Waiting Lamps - Telephone Number CMWL_T:Control Message Waiting Lamps - Telephone Number 1. Functional Outline This command is used to control/display the Message Waiting Lamp’s ON/OFF status, by using Telephone Numbers. When the station is a D term, this command can also be used to control the Message Waiting Lamp Display. This command is available at NCN (for Fusion network) only. Note Note: This command is available for PBX program...
Page 648
CHAPTER 8 NDA-24307 Page 620 Issue 1 CPRS: Controlled Alternate PRSCs CPRS:Controlled Alternate PRSCs 1. Functional Outline This command is necessary for the Controlled Alternate PRSCs function. It either selects the class used be- tween two priority restriction classes (Normal or Urgent), or indicates the class used. This command is allowed only when bit1 of SYS 1, INDEX 59 is “1” (Controlled Alternate PRSCs in service). 2. Parameters N/U: Priority Restriction Class [N/U] N=Normal U=Urgent
Page 649
NDA-24307 CHAPTER 8 Page 621 Issue 1 CSCL: Continuous Change of Station Class CSCL:Continuous Change of Station Class 1. Functional Outline This command can change the station class information (RSC, SFC) continuously by designating the consecutive range of the station numbers. 2. Parameters Input data TN: Tenant Number STN(START): First Station Number [0-9, #, * (Max. 6 digits)] Note 1 STN(END): Last Station Number [0-9, #, * (Max. 6 digits)] Note 1 TEC(OLD): Telephone Equipment Class before change...
Page 650
CHAPTER 8 NDA-24307 Page 622 Issue 1 CSTN: Continuous Change of Station Number CSTN:Continuous Change of Station Number 1. Functional Outline This command can change a consecutive range of physical station numbers. 2. Parameters Input data TN: Tenant Number OLD STN(START): First Station Number before change [0-9, #, * (Max. 6 digits)] Note OLD STN(END): Last Station Number before change [0-9, #, * (Max. 6 digits)] Note NEW STN(START): First Station Number after change [0-9, #, * (Max. 6 digits)] Note...