Home > NEC > Communications System > NEC Neax 2400 Ipx System Operations And Maintenance Manual

NEC Neax 2400 Ipx System Operations And Maintenance Manual

Here you can view all the pages of manual NEC Neax 2400 Ipx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 631

NDA-24307 CHAPTER 8
Page 603
Issue 1
CADSD: Continuous Assignment of Station Data
CADSD:Continuous Assignment of Station Data
1. Functional Outline
This command can assign/delete many station data simultaneously which have consecutive numbers.
2. Parameters
Type: Assign/Delete
[When “Assign” is selected in the “Type” selection list box]
Input data
TN(START): Start Tenant Number
TN(END): End Tenant Number
STN(START): Start Station Number [Max. 6 digits] 
Note 1
STN(END): End Station Number [Max. 6 digits]...

Page 632

CHAPTER 8 NDA-24307
Page 604
Issue 1
CADSD: Continuous Assignment of Station Data
TEC: Telephone Equipment Class [1-31]
1=DP (10pps) 2=PB
3=DP/PB 4=DP (20pps)
5-11=Not used 12=D
term
13=Data Terminal via Dterm14=Hot Line
15=CAS Line 16=Data Terminal via Data Module
17=Not used 18=Virtual Line Appearance (for D
term Multi-Line)
19-22=Not used 23=ISDN Terminal
24-26=Not used 27=8 Conference Equipment
28-31=Not used
RSC: Route Restriction Class [0-15]
SFC: Service Feature Class [0-15]
Buttons
Execute: Click...

Page 633

NDA-24307 CHAPTER 8
Page 605
Issue 1
CADSD: Continuous Assignment of Station Data
[When “Delete” is selected in the “Type” selection list box]
Input data
TN(START): First Tenant Number
TN(END): Last Tenant Number
STN(START): First Station Number [Max. 6 digits]
STN(END): Last Station Number [Max. 6 digits]
STEP: :Station Count-up Step 
Note 1
If using “*” and “#” → [1-12]
If not using “*” and “#” → [1-10]
Note 1:In the parameter here, specify the size of increment between the consecutive station numbers...

Page 634

CHAPTER 8 NDA-24307
Page 606
Issue 1
CATK: Continuous Assignment of Trunk Data
CATK:Continuous Assignment of Trunk Data
1. Functional Outline
This command can assign/delete many trunk data simultaneously which have consecutive numbers.
2. Parameters
Type/KIND (
Note): Assign/Delete
Note:Ty p e  
KIND 
[When “Assign” is selected in the “Type/KIND” selection list box]
Input data
RT: R o u t e  N u m b e r
TK (START): First Trunk Number [1-768]
TK (END): Last Trunk Number [1-768]
STEP: Trunk Count-up Step...

Page 635

NDA-24307 CHAPTER 8
Page 607
Issue 1
CATK: Continuous Assignment of Trunk Data
Buttons
Execute: Click to make the input data valid.
Cancel: Click to cancel the input data.
Exit: Click to exit this command.
Display data
TK: Assigned Trunk Number
LENS: Line Equipment Number
STATUS: Data Entry Result
OK=Data Assignment Is Successful 
Note 4
Note 4:
If not OK (i.e. the data entry is not successful), related error message is displayed here. 

Page 636

CHAPTER 8 NDA-24307
Page 608
Issue 1
CATK: Continuous Assignment of Trunk Data
[When “Delete” is selected in the “Type/KIND” selection list box]
Input data
RT: R o u t e  N u m b e r
TK(START): First Trunk Number [1-768]
TK(END): Last Trunk Number [1-768]
STEP: Trunk Count-up Step [1-10] 
Note 1
Buttons
Execute: Click to delete the input data.
Cancel: Click to cancel the deletion.
Exit: Click to exit this command.
Display data
TK: Trunk Number
STATUS: Result of Deletion
OK=Deletion Success 
Note 2
Note...

Page 637

NDA-24307 CHAPTER 8
Page 609
Issue 1
CATK: Continuous Assignment of Trunk Data
[Details on Trunk Arrangement “TYPE”]
When assigning the consecutive trunk data by using the CATK command, you must select the trunk arrange-
ment type (1-6) in the “TYPE” parameter. See the detailed examples below:
The following are the examples when the 16 COT circuit cards are accommodated as shown below.
TYPE=1 (Level → Group → Unit)
Trunk data is arranged in the following numerical order.
U=2
00
PIM C/EU=3
05 10 15 20...

Page 638

CHAPTER 8 NDA-24307
Page 610
Issue 1
CATK: Continuous Assignment of Trunk Data
TYPE=2 (Level → Unit → Group)
Trunk data is arranged in the following numerical order.
TYPE=3 (Group → Level → Unit)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6
LV 71
2
3
4
5
6
7
8
0233 40
0381 88
0565 72
04
17 2449
56
05 06
U=2
U=0
03 02 9 16
00
41 48
01
57 6425
32
16 15
U=3
U=1
73 8089
96
Group No. Level No.
1MGSlot No.
LV 7
LV 6
LV 5...

Page 639

NDA-24307 CHAPTER 8
Page 611
Issue 1
CATK: Continuous Assignment of Trunk Data
TYPE=4 (Group → Unit → Level)
Trunk data is arranged in the following numerical order.
TYPE=5 (Unit → Level → Group)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6
LV 71 13 85
024 88
05 7 91
8 92
05 06
U=2
U=0
03 02 5 89
006 90
01 9 93
16 15
U=3
U=1
12 96
Group No. Level No.
1MGSlot No.
16 17 18
2
033
04 19 20 21 24
LV 7
LV 6
LV 5
LV 4
LV 3...

Page 640

CHAPTER 8 NDA-24307
Page 612
Issue 1
CATK: Continuous Assignment of Trunk Data
TYPE=6 (Unit → Group → Level)
Trunk data is arranged in the following numerical order.
LV 7
LV 6
LV 5
LV 4
LV 3
LV 2
LV 1
LV 0
LV 0 LV 1
LV 2
LV 3
LV 4
LV 5
LV 6
LV 71 13 85
0211 95
05 3 87
7 91
05 06
U=2
U=0
03 02 2 86
006 90
01 4 89
16 15
U=3
U=1
12 96
Group No. Level No.
1MGSlot No.
23 14 18
5
039
04 15 19 16 24
92 94
20 22
810
17 21 89 93 
Start reading NEC Neax 2400 Ipx System Operations And Maintenance Manual

Related Manuals for NEC Neax 2400 Ipx System Operations And Maintenance Manual

All NEC manuals