Page 631
NDA-24307 CHAPTER 8 Page 603 Issue 1 CADSD: Continuous Assignment of Station Data CADSD:Continuous Assignment of Station Data 1. Functional Outline This command can assign/delete many station data simultaneously which have consecutive numbers. 2. Parameters Type: Assign/Delete [When “Assign” is selected in the “Type” selection list box] Input data TN(START): Start Tenant Number TN(END): End Tenant Number STN(START): Start Station Number [Max. 6 digits] Note 1 STN(END): End Station Number [Max. 6 digits]...
Page 632
CHAPTER 8 NDA-24307 Page 604 Issue 1 CADSD: Continuous Assignment of Station Data TEC: Telephone Equipment Class [1-31] 1=DP (10pps) 2=PB 3=DP/PB 4=DP (20pps) 5-11=Not used 12=D term 13=Data Terminal via Dterm14=Hot Line 15=CAS Line 16=Data Terminal via Data Module 17=Not used 18=Virtual Line Appearance (for D term Multi-Line) 19-22=Not used 23=ISDN Terminal 24-26=Not used 27=8 Conference Equipment 28-31=Not used RSC: Route Restriction Class [0-15] SFC: Service Feature Class [0-15] Buttons Execute: Click...
Page 633
NDA-24307 CHAPTER 8 Page 605 Issue 1 CADSD: Continuous Assignment of Station Data [When “Delete” is selected in the “Type” selection list box] Input data TN(START): First Tenant Number TN(END): Last Tenant Number STN(START): First Station Number [Max. 6 digits] STN(END): Last Station Number [Max. 6 digits] STEP: :Station Count-up Step Note 1 If using “*” and “#” → [1-12] If not using “*” and “#” → [1-10] Note 1:In the parameter here, specify the size of increment between the consecutive station numbers...
Page 634
CHAPTER 8 NDA-24307 Page 606 Issue 1 CATK: Continuous Assignment of Trunk Data CATK:Continuous Assignment of Trunk Data 1. Functional Outline This command can assign/delete many trunk data simultaneously which have consecutive numbers. 2. Parameters Type/KIND ( Note): Assign/Delete Note:Ty p e KIND [When “Assign” is selected in the “Type/KIND” selection list box] Input data RT: R o u t e N u m b e r TK (START): First Trunk Number [1-768] TK (END): Last Trunk Number [1-768] STEP: Trunk Count-up Step...
Page 635
NDA-24307 CHAPTER 8 Page 607 Issue 1 CATK: Continuous Assignment of Trunk Data Buttons Execute: Click to make the input data valid. Cancel: Click to cancel the input data. Exit: Click to exit this command. Display data TK: Assigned Trunk Number LENS: Line Equipment Number STATUS: Data Entry Result OK=Data Assignment Is Successful Note 4 Note 4: If not OK (i.e. the data entry is not successful), related error message is displayed here.
Page 636
CHAPTER 8 NDA-24307 Page 608 Issue 1 CATK: Continuous Assignment of Trunk Data [When “Delete” is selected in the “Type/KIND” selection list box] Input data RT: R o u t e N u m b e r TK(START): First Trunk Number [1-768] TK(END): Last Trunk Number [1-768] STEP: Trunk Count-up Step [1-10] Note 1 Buttons Execute: Click to delete the input data. Cancel: Click to cancel the deletion. Exit: Click to exit this command. Display data TK: Trunk Number STATUS: Result of Deletion OK=Deletion Success Note 2 Note...
Page 637
NDA-24307 CHAPTER 8 Page 609 Issue 1 CATK: Continuous Assignment of Trunk Data [Details on Trunk Arrangement “TYPE”] When assigning the consecutive trunk data by using the CATK command, you must select the trunk arrange- ment type (1-6) in the “TYPE” parameter. See the detailed examples below: The following are the examples when the 16 COT circuit cards are accommodated as shown below. TYPE=1 (Level → Group → Unit) Trunk data is arranged in the following numerical order. U=2 00 PIM C/EU=3 05 10 15 20...
Page 638
CHAPTER 8 NDA-24307 Page 610 Issue 1 CATK: Continuous Assignment of Trunk Data TYPE=2 (Level → Unit → Group) Trunk data is arranged in the following numerical order. TYPE=3 (Group → Level → Unit) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 2 3 4 5 6 7 8 0233 40 0381 88 0565 72 04 17 2449 56 05 06 U=2 U=0 03 02 9 16 00 41 48 01 57 6425 32 16 15 U=3 U=1 73 8089 96 Group No. Level No. 1MGSlot No. LV 7 LV 6 LV 5...
Page 639
NDA-24307 CHAPTER 8 Page 611 Issue 1 CATK: Continuous Assignment of Trunk Data TYPE=4 (Group → Unit → Level) Trunk data is arranged in the following numerical order. TYPE=5 (Unit → Level → Group) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 024 88 05 7 91 8 92 05 06 U=2 U=0 03 02 5 89 006 90 01 9 93 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 16 17 18 2 033 04 19 20 21 24 LV 7 LV 6 LV 5 LV 4 LV 3...
Page 640
CHAPTER 8 NDA-24307 Page 612 Issue 1 CATK: Continuous Assignment of Trunk Data TYPE=6 (Unit → Group → Level) Trunk data is arranged in the following numerical order. LV 7 LV 6 LV 5 LV 4 LV 3 LV 2 LV 1 LV 0 LV 0 LV 1 LV 2 LV 3 LV 4 LV 5 LV 6 LV 71 13 85 0211 95 05 3 87 7 91 05 06 U=2 U=0 03 02 2 86 006 90 01 4 89 16 15 U=3 U=1 12 96 Group No. Level No. 1MGSlot No. 23 14 18 5 039 04 15 19 16 24 92 94 20 22 810 17 21 89 93