5.4Speech Path System Fault - STBY Side Has Become Faulty
Faulty Situation:
 A fault occurred in the STBY side of the dual configuration system.
[1-B] TSW Failure (Permanent)
[1-D] TSW Write Failure
[1-F] TSW Clock Failure
[4-D] TSW Ready Failure
Check to see if the TSW circuit card is mak-
ing poor contact.Set the TSW MBR switch of the TSW circuit
card UP.
Set the MB switch of the TSW circuit card UP
and extract the circuit card from...

Page 382

NDA-24238 CHAPTER 5
Page 355
Revision 3.0
FAULT REPAIR PROCEDURES
Faulty Situation:
 Fault related to speech such as noise, one-way speech, no-speed, etc. occurs.
 Even if dialing started, Dial Tone (DT) does not stop.
[1-C] Both TSW Write Failure
[1-D] TSW Write Failure
Check to see if fault occurs by extracting
TSW circuit cards one by one.Replace the TSW circuit card referring to Sec-
tion 2.3.2, TSW Card Replacement Procedure
in Chapter 4.
Set the TSW circuit card into ACT mode by
flipping the...

Page 383

CHAPTER 5 NDA-24238
Page 356
Revision 3.0
FAULT REPAIR PROCEDURES
6. CONTROL SYSTEM FAULT
This section explains the fault repair procedure for the control system listed in Table 5-8.
6.1 Check Point
When repairing the control system, check the status of the following lamps:
CPR
GT
 TSW
MUX
 EMA circuit cards
Figure 5-9 shows a block diagram of the CPU controlling block, where CPU #0 is active.
Table 5-8  Control System Fault Situation
FAULTY SITUATION REFERENCE SECTION
Fault occurs occasionally at...

Page 384

NDA-24238 CHAPTER 5
Page 357
Revision 3.0
FAULT REPAIR PROCEDURES
Figure 5-9   CPU Controlling Block Diagram
LPM
EMAIOC /
MISC
ISAGT 0
LANI
PWR
PWR
CPU 0
MEMORY
PCI BUSISA BUS
CPU board CPR
CPU clock
   CPR
(ST-BY)
Reset Signal
MISC BUS
MISC BUS
ISAGT 1 T
MT
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
IMG0
PIM 3
PIM 2
PIM 1
PIM 0
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS...

Page 385

CHAPTER 5 NDA-24238
Page 358
Revision 3.0
FAULT REPAIR PROCEDURES
Figure 5-9  CPU Controlling Block Diagram (Continued)
LPM
EMAIOC /
MISC
ISAGT 0
LANI
PWR
PWR
CPU 0
MEMORY
PCI BUSISA BUS
CPU board CPR
CPU clock
   CPR
(ST-BY)
Reset Signal
MISC BUS
MISC BUS
ISAGT 1 T
MT
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
IMG2
PIM 3
PIM 2
PIM 1
PIM 0
LC/TRK
MUX
MUX
LC/TRK
PM BUS
PM BUS
LC/TRK
MUX
MUX
LC/TRK
PM...

Page 386

NDA-24238 CHAPTER 5
Page 359
Revision 3.0
FAULT REPAIR PROCEDURES
6.2 Control System Fault - Fault Occurs Intermittently
Faulty Situation:
 Fault occurs intermittently at ACT side in the dual configuration system.
 Fault occurs intermittently in the single configuration system.
[0-C] ~ [0-K] CPU Failure
[1-C] Both TSW Write Failure
[1-D] TSW Write Failure
[3-D], [3-E] Lock-Up Failure (Permanent/Temporary)
(1) For Dual Configuration
Replace ACT-side related circuit card
(CPU, GT, TSW, MUX, EMA) with...

Page 387

CHAPTER 5 NDA-24238
Page 360
Revision 3.0
FAULT REPAIR PROCEDURES
(2) For Single Configuration
Replace the related circuit card (CPU, GT,
TSW, MUX, EMA) with a spare, and check.Replace the circuit card (CPU, GT, TSW, MUX, 
EMA) individually by referring to the following 
sections in Chapter 4:
Section 1.3.1, CPR Replacement Procedure
Section 1.3.2, EMA Card Replacement
Procedure
Section 2.3.1, GT Card Replacement
Procedure
Section 2.3.2, TSW Card Replacement
Procedure
Section 3.3.2, MUX Card...

Page 388

NDA-24238 CHAPTER 5
Page 361
Revision 3.0
FAULT REPAIR PROCEDURES
6.3 Control System Fault - STBY Side Is Faulty
Faulty Situation:
 Fault has occurred in the STBY side of dual configuration system.
[0-I] STBY CPU Failure
 The ACT side has become faulty, and system changeover has executed.
[0-C], [0-H], [0-J] Processor Failure (ACT side)
Replace STBY side related circuit cards
(CPU, GT, TSW, MUX, EMA) with a spare,
and check.Replace the circuit cards (CPU, GT, TSW, 
MUX, EMA) individually by referring...

Page 389

CHAPTER 5 NDA-24238
Page 362
Revision 3.0
FAULT REPAIR PROCEDURES
Figure 5-10   Alarm Bus Cable Connections Diagram
IMG 0
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 3
ALMA
ALMB
DSPLTO P U
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 0
ALMA
ALMB
LED3
LED2
LED1
ALM3
MUSIC
ALM2
ALM1EMA
EMAFH
ALM
ALM
DSP
PA L M 1
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 1
ALMA
ALMB
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 2
ALMA
ALMB
PZ-DK222
IMG 1
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 3
ALMA
ALMB
DSPMTOPU
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 0
ALMA
ALMB
TSWM
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 1...

Page 390

NDA-24238 CHAPTER 5
Page 363
Revision 3.0
FAULT REPAIR PROCEDURES
Figure 5-10  Alarm Bus Cable Connections Diagram (Continued)
IMG 2
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 3
ALMA
ALMB
DSPM     TOPU
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 0
ALMA
ALMB
LED3
LED2
LED1
ALM3
MUSIC
ALM2
ALM1
DSP
DSP
PA L M 1
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 1
ALMA
ALMB
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 2
ALMA
ALMB
PZ-DK222
IMG 3
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 3
ALMA
ALMB
DSPMTO P U
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 0
ALMA
ALMB
MUX 0LC/TRKMUX 1PWR
DPWR
PIM 1
ALMA...
Start reading NEC Neax 2400 Imx System Operations And Maintenance Manual

Related Manuals for NEC Neax 2400 Imx System Operations And Maintenance Manual

All NEC manuals