NEC Neax 2400 Imx System Operations And Maintenance Manual
Here you can view all the pages of manual NEC Neax 2400 Imx System Operations And Maintenance Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.
Page 341
CHAPTER 5 NDA-24238 Page 314 Revision 3.0 FAULT REPAIR PROCEDURES Check the faulty line on the MDF. Isolate the faulty line to the in-house wiring side and to the system side. Connect the test telephone to the system side and check to see if dial tone can be heard. When Dial Tone (DT) is heard Check the in-house wirings. Replace the station telephone set with a spare. When no DT or side tone is heardCheck LT cables. Replace the LC circuit card with a spare. When DT is not heard, but side tone can be...
Page 342
NDA-24238 CHAPTER 5 Page 315 Revision 3.0 FAULT REPAIR PROCEDURES 1.4 Line Fault - When Dialing Results in Wrong Connection Note:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replacement is complete. When a call addressed to a specific station has terminated to another stationCheck to see if Call Forwarding-All Calls data has been deleted. Check the faulty line on the MDF. On the MDF, isolate the faulty line to the in- house...
Page 343
CHAPTER 5 NDA-24238 Page 316 Revision 3.0 FAULT REPAIR PROCEDURES 1.5 Line Fault - When Bell Does Not Ring Note:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replacement is complete. Call the faulty station line by Station-to- Station calling and check to see if the bell of the telephone rings.Replace the telephone set and check to see if its bell rings. Check the faulty line on the MDF. Isolate the faulty line to the...
Page 344
NDA-24238 CHAPTER 5 Page 317 Revision 3.0 FAULT REPAIR PROCEDURES 1.6 When Call Cannot Be Answered and Speech Cannot Be Made Note:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replacement is complete. Check the faulty line on the MDF. Isolate the faulty line to the in-house wiring side and to the system side. Connect the test telephone to the system side. Call the faulty line by station-to-station calling. When speech can...
Page 345
CHAPTER 5 NDA-24238 Page 318 Revision 3.0 FAULT REPAIR PROCEDURES 1.7 Dterm Fault Note 1:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replacement is complete. Note 2:If any of the in-house cable wirings short-circuit, the POW ALM lamp on the ELC circuit card lights. Remove the cause of the short-circuit and initialize the ELC circuit card. When OPE lamp on the ELC circuit card does not illuminateConfirm that MB switch of the ELC...
Page 346
NDA-24238 CHAPTER 5 Page 319 Revision 3.0 FAULT REPAIR PROCEDURES Check the faulty line on the MDF. Isolate the faulty line to the in-house wiring side and to the system side. Connect the test D term to the system side. Confirm speech by Station-to-Station calling. When no speech can be made. Check LT cables. Replace ELC circuit card with a spare. When speech can be made. Check to see if the modular plug is firmly connected with the D term. Check the wiring inside the rosette. Check the in-house...
Page 347
CHAPTER 5 NDA-24238 Page 320 Revision 3.0 FAULT REPAIR PROCEDURES 2. TRUNK FAULT This paragraph explains the fault repair procedure when a fault, shown in Table 5-3, has occurred to a specific trunk. 2.1 Check Point When repairing a trunk fault, consider the following items: (1) Check alarm lamps on trunk circuit cards. (2) When an outgoing call cannot be originated to a specific trunk or when an incoming call cannot be termi- nated from a specific trunk, check Tenant Restriction Data (assigned via ATNR...
Page 348
NDA-24238 CHAPTER 5 Page 321 Revision 3.0 FAULT REPAIR PROCEDURES Table 5-4 Timings for Trunks ITEMS FOR STATUS SUPERVISIONCONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS 1 Detection of Call Termination Ring Down System Detection by ringing signal (20Hz) from the opposite office. Loop System Detection by loop from the opposite office. E&M System Detection by incoming signal (ground or – 48V) on E (RG2) lead.Ringing signal of more than 4 cycles is detected within 800 ms. Detection within 16 ms...
Page 349
CHAPTER 5 NDA-24238 Page 322 Revision 3.0 FAULT REPAIR PROCEDURES Table 5-5 Timings for Senders ITEMS FOR STATUS SUPERVISIONCONDITIONS FOR SUPERVISION TIMING SPECIFICATIONS 1 Sender Acknowledge Wait Ti merTiming limit for waiting to receive connection acknowledgement signal from the opposite office after seizing the opposite office.4 sec. (standard) Timing can be assigned using ASYD SYS 1 Index 130 command. 2 Sender Prepause Timer Time from sender seizure till sending of the 1st digit where...
Page 350
NDA-24238 CHAPTER 5 Page 323 Revision 3.0 FAULT REPAIR PROCEDURES 2.2 Trunk Control Trunk circuit cards are controlled from the CPU via the MUX. Each trunk line in a specific trunk circuit card is controlled by the Port Microprocessor (PM) in a trunk circuit card. Figure 5-2 shows the control route of the trunk circuit card. Figure 5-2 Controlling Trunk Circuit Cards and Speech Path TRK TDSW/INT GT CPU CPR TSW MDF LT Cable LT Cable Control Signal Speech Path Control SignalCOT/TLT Symbols: :...