Page 351
CHAPTER 5 NDA-24238 Page 324 Revision 3.0 FAULT REPAIR PROCEDURES 2.3 Trunk (ORT, SND, CFT) Fault Note:If a circuit card is replaced because only one line is faulty, no other lines in that circuit card can be used until the replace- ment is complete. When only one line is faulty Place the faulty line into make-busy state. For ORT/SND, set MB switch of each circuit to ON position. For CFT, place it into make-busy state using command MBTK. Replace the circuit card with spare. Set MB switch UP and...
Page 352
NDA-24238 CHAPTER 5 Page 325 Revision 3.0 FAULT REPAIR PROCEDURES 2.4 Trunk (COT, TLT, DTI) Fault Note 1:If a circuit card is replaced because only one line is faulty, any other lines in that circuit card cannot be used until the replacement is complete. Note 2:If the polarities of the external line is reversed, it is detected in the form of Trunk Ineffective Hold. When OPE lamp on the trunk circuit card does not illuminateConfirm that MB switch of the trunk circuit card is in ON position (UP side)....
Page 353
CHAPTER 5 NDA-24238 Page 326 Revision 3.0 FAULT REPAIR PROCEDURES Check the faulty line on the MDF. If the C.O./Tie Line is in Loop Start system: Isolate the faulty line to C.O. side and to the system side. Connect the test telephone to the C.O. side. Note 1:Check can be made only on temporarily opened C.O./Tie Lines.Confirm that Dial Tone (DT) is heard and the call is connected to the desti- nation party at the opposite office. Note 2:Cross connection methods are explained on the following pages.If...
Page 354
NDA-24238 CHAPTER 5 Page 327 Revision 3.0 FAULT REPAIR PROCEDURES Note: When performing loop-back connection tests on the trunks at the user’s office, provide cross connection as follows: (1) For a COT Set up a loop-back connection between the COT (C.O. Trunk) to be tested and station line. The trunk route must be assigned for Loop Start. (2) For a TLT (for DID) Set up a loop-back connection between the Tie Line Trunk (TLT) to be tested and another TLT. If the TLT is a Direct Inward Dialing (DID)...
Page 355
CHAPTER 5 NDA-24238 Page 328 Revision 3.0 FAULT REPAIR PROCEDURES If the TLT is a 2W E & M System, connect the related leads as shown below: (3) For a DTI Set up a loop-back connection between the DTI Trunk to be tested and another DTI Trunk as shown below: If the office is the PLO-source office, perform the tests by disconnecting the PLO and M-OSC. The mode of the PLO becomes Self Operation Mode. When the loop-back test is performed at the time of PCM LOSS, FRM LOSS, or MERM LOSS alarm lamp...
Page 356
NDA-24238 CHAPTER 5 Page 329 Revision 3.0 FAULT REPAIR PROCEDURES 3. ATTCON/DESKCON FAULT This section explains the fault repair procedure when a specific Attendant Console (ATTCON) is in any of the following faulty conditions. No speech can be made. No operations can be made. 3.1 Check Point When repairing an ATTCON/DESKCON fault, consider the following items: (1) Check the cable connections on the backplane. (2) When replacing the ATI circuit card for master ATTCON/DESKCON, the system is placed...
Page 357
CHAPTER 5 NDA-24238 Page 330 Revision 3.0 FAULT REPAIR PROCEDURES Figure 5-3 ATT Connector Cabling and Connector Leads Accommodation LT5 LT11 PIM Backplane MDFATTCON/ DESKCONLT11 is used when PA-CS33 is mounted in Slot 23. LT5 is used when PA-CS33 is mounted in Slot 12. 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 47 34 35 36 37 38 39 40 41 42 43 44 45 46 48 BN4801 BN4800 BN4820 BN4821 TAS1B TAS1A BN4810 BN4830 BN4831BN4811 TAS0B TAS0A B2 A2 B3 A3 PA-CS33 Pin Assignment Installation CableInstallation...
Page 358
NDA-24238 CHAPTER 5 Page 331 Revision 3.0 FAULT REPAIR PROCEDURES 3.3 ATTCON/DESKCON Fault Note 1:No speech can be made. Note 2:While replacement of the ATI circuit card for the master ATTCON/DESKCON is in progress, the system is placed under Night Mode. On the ATTCON/DESKCON, LCHK (Lamp Check) key has been pressed but no lamps have illuminated.Check the ATT connector cable between the ATTCON/DESKCON and the PBX. When the OPE lamp of the ATI (PA- CS33) circuit card does not illuminateConfirm that MB...
Page 359
CHAPTER 5 NDA-24238 Page 332 Revision 3.0 FAULT REPAIR PROCEDURES Note: No operations can be made. Replace the ATTCON/DESKCON with a spare.Set the MB switch of ATI PA-CS33 circuit card UP. If the circuit card is equipped with a fuse, remove the fuse. Disconnect the CHAMP connector of the ATTCON/DESKCON and replace the ATTCON/DESKCON. If the circuit card is equipped with a fuse, insert the fuse into its position. Set the MB switch of the ATI circuit card DOWN. Confirm the PA lamp illuminates on the...
Page 360
NDA-24238 CHAPTER 5 Page 333 Revision 3.0 FAULT REPAIR PROCEDURES 4. UNIT FAULT This section explains the fault repair procedure in a case where any of the faults shown in Table 5-6 has oc- curred to all the line/trunk circuit cards mounted in a specific unit. Figure 5-4 shows the range of units. Figure 5-4 Range of Units Table 5-6 Unit Fault Situation FAULT SITUATION REFERENCE SECTION Noise, one-way speech, no tone. Even if dialing has been made, dial tone does not stop.Section 4.2, Unit Fault -...