CHAPTER 5 NDA-24238 Page 344 Revision 3.0 FAULT REPAIR PROCEDURES 4.4 Unit Fault - ACT-Side MUX Card Is Faulty and System Has Changed Over Faulty Situation: The ACT side has become faulty and the system changeover has executed in the dual configuration system. [4-S] MUX Ready Failure / [4-T] Both MUX Failure [23-Y] MUX Clock Failure Check to see if the MUX (PH-PC36) circuit card of the STBY side is making poor contact. If the connection is set up, set the faulty system into STBY side.Set the MB...
Page 372
NDA-24238 CHAPTER 5 Page 345 Revision 3.0 FAULT REPAIR PROCEDURES Replace the MUX circuit card with a spare, and check it.Replace the MUX circuit card referring to Section 3.3.2, MUX Card Replacement Procedure in Chapter 4. Place the MUX circuit card into ACT mode by flipping the MBR key on the active GT (PH-GT09) card. Refer to Section 12.1.6, Manual System Changeover of Speech Path System, in Chapter 6. Check to see if a station-to-station connection can be set up and identify a circuit card...
Page 373
CHAPTER 5 NDA-24238 Page 346 Revision 3.0 FAULT REPAIR PROCEDURES 5. SPEECH PATH (TSW) SYSTEM FAULT This section explains the fault repair procedure when any of the faults shown in Table 5-7 has occurred in the whole system. 5.1 Check Point When repairing a speech path fault, consider that when any of the faults shown in Ta b l e 5 - 7 have occurred in the system, it is possible that the TSW circuit card is at fault. Always check the alarm lamps on the TSW circuit card. Table 5-7 Speech Path (TSW)...
Page 374
NDA-24238 CHAPTER 5 Page 347 Revision 3.0 FAULT REPAIR PROCEDURES Figure 5-8 Speech Path Block Diagram IMG0 TSW 02 To IMG2 TSWM TSW 00 TSW/INTMUX 003 MUX 002 MUX 001 MUX 000 PIM 3 LC/TRK MUX Symbols : Speech Path : Circuit Card (active) TSW: PH-SW12 MUX: PH-PC36 LC/TRKLC/TRK MUX PIM 2 LC/TRK MUX LC/TRKLC/TRK MUX PIM 1 LC/TRK MUX LC/TRKLC/TRK MUX PIM 0 LC/TRK MUX LC/TRKLC/TRK MUX IMG1 PIM 3 LC/TRK MUX LC/TRKLC/TRK MUX PIM 2 LC/TRK MUX LC/TRKLC/TRK MUX PIM 1 LC/TRK MUX...
Page 375
CHAPTER 5 NDA-24238 Page 348 Revision 3.0 FAULT REPAIR PROCEDURES Figure 5-8 Speech Path Block Diagram (Continued) IMG2 TSW 00 To IMG0 TSWM TSW 02 TSW/INTMUX 023 MUX 022 MUX 021 MUX 020 PIM 3 LC/TRK MUX Symbols : Speech Path : Circuit Card (Active) TSW: PH-SW12 MUX: PH-PC36 LC/TRKLC/TRK MUX PIM 2 LC/TRK MUX LC/TRKLC/TRK MUX PIM 1 LC/TRK MUX LC/TRKLC/TRK MUX PIM 0 LC/TRK MUX LC/TRKLC/TRK MUX IMG3 PIM 3 LC/TRK MUX LC/TRKLC/TRK MUX PIM 2 LC/TRK MUX LC/TRKLC/TRK MUX PIM 1 LC/TRK...
Page 376
NDA-24238 CHAPTER 5 Page 349 Revision 3.0 FAULT REPAIR PROCEDURES 5.2 Speech Path System Fault - Fault Related to Speech Faulty Situation: Fault related to speech such as noise, one-way speech, no-speed, etc. occurs. Even if dialing started, Dial Tone (DT) does not stop. [1-C] Both TSW Write Failure [1-D] TSW Write Failure (1) For Dual Configuration Check to see if fault occurs by extracting TSW circuit cards one by one.Replace the TSW circuit card referring to Section 2.3.2, TSW Card Replacement...
Page 377
CHAPTER 5 NDA-24238 Page 350 Revision 3.0 FAULT REPAIR PROCEDURES Check to see if a station-to-station connection can be set up and identify a circuit card respon- sible for the fault. Perform the above check by extracting the MUX circuit cards individually. When the PLO (PH-CK16/17/16-A/17-A) circuit card is mounted for digital interface, replace PLO circuit card with a spare and check.Set MB switch of the PLO circuit card to UP side. Confirm OPE lamp on the PLO circuit card of the mate system...
Page 378
NDA-24238 CHAPTER 5 Page 351 Revision 3.0 FAULT REPAIR PROCEDURES (2) For Single Configuration Check to see if the fault occurs by extracting TSW circuit cards one by one.Replace the TSW circuit card referring to Section 2.3.2, TSW Card Replacement Procedure, in Chapter 4. Check to see if a station-to-station connection can be set up and identify a TSW circuit card responsible for the fault. Perform the above check by extracting the TSW circuit cards individually. Check to see if the fault occurs by...
Page 379
CHAPTER 5 NDA-24238 Page 352 Revision 3.0 FAULT REPAIR PROCEDURES When the PLO (PH-CK16/17) circuit card is mounted for digital interface, replace the PLO circuit card with a spare and check it.Set MB switch of the PLO circuit card to UP side. Confirm ACT lamp on the PLO circuit card goes out. Extract PLO circuit card from its mounting slot. Set MB switch UP and insert the new PLO circuit card into its mounting slot. Set MB switch DOWN. Confirm the ACT lamp on the new PLO circuit card illuminates....
Page 380
NDA-24238 CHAPTER 5 Page 353 Revision 3.0 FAULT REPAIR PROCEDURES 5.3 Speech Path System Fault - When Dial Tone (DT) Cannot Be Heard Faulty Situation: Dial Tone (DT) cannot be heard. [1-A] Both TSW Failure (Permanent) [1-E] Both TSW Clock Failure [4-C] Both TSW Ready Failure [23-Y] MUX Clock Failure Note:For dual system configuration, if a system message indicates that both systems are faulty, first repair the fault in the indicated system and then proceed to repair the PIM in the other system....