CHAPTER 6 NDA-24238 Page 394 Revision 3.0 SYSTEM OPERATIONS 2.2 Display on MAT Set Scanning to Scanning ON (default) on the Scanning PBX form to collect system messages. If any mes- sage is collected, the information is displayed in the text box on the DFTD command form. 3. INDICATION OF LOCKOUT STATIONS When a station is in lockout status (permanent signaling state, shorting across speech wires, etc.), it can quickly be discovered, preventing the situation from developing into serious trouble. 3.1...
Page 422
NDA-24238 CHAPTER 6 Page 395 Revision 3.0 SYSTEM OPERATIONS Figure 6-5 Recovery Procedure From Lockout Station (Continued) COMMAND COMMAND FULL NAME RLSTRelease Station/Trunk A RLST command (Confirm: DT) Hear DT? Replace 16LC card with a spare.Circuit may be faulty temporarily. Observe situation for a while.Forcibly release the lockout station circuit. Go off-hook again and confirm DT. YES NO
Page 423
CHAPTER 6 NDA-24238 Page 396 Revision 3.0 SYSTEM OPERATIONS 4. LINE LOAD CONTROL In the PBX, Line Load Control can be activated automatically or manually as a countermeasure against abnor- mal traffic congestion. In the case of automatic control, the system automatically monitors an overloaded situation and restricts out- going calls from stations and incoming calls from trunks. In the case of manual control, the operator at an Attendant/Desk Console or the MAT restricts outgoing calls from stations and...
Page 424
NDA-24238 CHAPTER 6 Page 397 Revision 3.0 SYSTEM OPERATIONS Cancelling Figure 6-7 Line Load Control Operations on ATTCON—Cancelling Figure 6-8 Locations of Lamps (ATTCON) Press LOOP key. Press CANCEL key.Lamp (Figure 6-8) on control panel lights. System message [6-D] displays. (SST) Dial the access code for cancelling Line Load Control. LAMPNEC
Page 425
CHAPTER 6 NDA-24238 Page 398 Revision 3.0 SYSTEM OPERATIONS (2) Key Operations on the Desk Console (DESKCON) By the operations on the Desk Console, restriction is applied on an outgoing call from a station having SFC in which the SFI = 16 (Line Load Control) of ASFC command is set as RES=0 (incoming calls to that station are allowed). For restricting incoming calls from a trunk, system data ASYD, SYS1, INDEX59, b0=1 should be assigned. Setting Figure 6-9 Line Load Control Key Operations on...
Page 426
NDA-24238 CHAPTER 6 Page 399 Revision 3.0 SYSTEM OPERATIONS Figure 6-11 Line Load Control Indication (DESKCON) (3) Operations on the MAT By entering ALLC command from the MAT, Line Load Control executes. The station to be controlled and the contents of the Line Load Control executed on the MAT are the same as those in Step (1), Operations on the Attendant Console. (4) Automatic Setting If the usage rate of the CPU exceeds the system data usage rate, Line Load Control is automatically set. In this case,...
Page 427
CHAPTER 6 NDA-24238 Page 400 Revision 3.0 SYSTEM OPERATIONS 5. IOC LINE MONITOR (1) Functional Outline This function monitors the IOC port status. As a result of the monitoring by this function, the following is executed: When the connection with a port has been disconnected, it is reported by a message. When the connection with a port is set up, it is reported by a message. The port status is stored in the memory and updated continuously. (2) Message Judgment Criteria Table 6-2 describes the...
Page 428
NDA-24238 CHAPTER 6 Page 401 Revision 3.0 SYSTEM OPERATIONS 6. LINE MANAGEMENT The following explanations apply to line management: Make-Busy/Make-Busy Cancel of Station and Data Terminal Class Change and Number Change of Station and Data Terminal Make-Busy/Make-Busy Cancel of C.O. Line/Tie Line 6.1 Make-Busy/Make-Busy Cancel of Station and Data Terminal Stations and data terminals can be put into make-busy state by the following operations: (1) On each station basis using the MBST command. Assign...
Page 429
CHAPTER 6 NDA-24238 Page 402 Revision 3.0 SYSTEM OPERATIONS 6.2 Class Change and Number Change of Station and Data Terminal Figure 6-12 shows the procedure for class change and number change of station and data terminal. Figure 6-12 Class Change and Number Change of Station and Data Terminal Procedure 6.3 Make-Busy/Make-Busy Cancel of C.O. Line/Tie Line Figure 6-13 shows the procedure to make-busy/make-busy cancel of C.O. line/tie line. Figure 6-13 Make-Busy/Make-Busy Cancel of C.O. Line/Tie Line...
Page 430
NDA-24238 CHAPTER 6 Page 403 Revision 3.0 SYSTEM OPERATIONS 6.4 Line Management Commands 7. STATION MESSAGE DETAIL RECORDING SYSTEM (SMDR) Billing information can be managed by connecting the PBX system and an external computer (SMDR equip- ment). Note:The SMDR equipment and its software must be provided by the user. The PBX system provides the SMDR equipment with the following information: Calling Party Information Called Party Number Call Start Time Call End Time Call Data Authorization...