NEC Neax 2400 Imx Oai System Manual
Have a look at the manual NEC Neax 2400 Imx Oai System Manual online for free. It’s possible to download the document as PDF or print. UserManuals.tech offer 1168 NEC manuals and user’s guides for free. Share the user manual or guide on Facebook, Twitter or Google+.
ND-70895 (E) CHAPTER 5 Page 61 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Basic Office Data for OAI System 2.2 Data for OAI Terminal In the case of Dterm 1. ASDT (In the case of Business; Station Data), AASP (In the case of Hotel system; Station Data) Note 1 Assign station data Voice Port: TEC12 Data Port: TEC13 (Normal setting for others) Note 1:For ASDT/AASP command, refer to the Command Manual of the NEAX2400 IMX. 2. AKYD (D term Key Data) Assign the function key data of Dterm Assign FKY34 – 47 to any positions of FKY 1–16. (Normal setting for others) 3. AOKC (OAI Key Code Data) Assign the OAI key code data OAI key code 1 ~ 14 respectively corresponds to FKY34 ~ 47 of AKYD 4. AOAC (OAI Access Code Data) If necessary, assign OAI access code data when using “OAI key + Access code” system to activate the application by MSF/TMF In the case of Single-Line Telephone 1. ASYD (System Data) Assign OAI Host Computer Respond Wait Timer 2. ANPD (Numbering Plan Data) Assign the minimum necessary number of digits for OAI Dial Number Continuous Transfer Code Note 2 3. ASPA (Special Access Code Data) Assign the OAI Dial Number Continuous Transfer Access Code SSCA: 69 (OAI Dial Number Continuous Transfer) NND : Necessary Number of Digits of OAI access code (Max. 3 digits) Note 2:For ANPD command, refer to the Command Manual of the NEAX2400 IMX. 4. AOAC (OAI Access Code Data) Assign OAI access code data
CHAPTER 5 ND-70895 (E) Page 62 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3. Procedure for Setting Office Data for OAI Services This section explains the outline, using conditions, and office data setting procedure of the main OAI service functions. 3.1 Switch Control Facility (SCF) 3.1.1 Functional Outline The SCF is the facility that executes, from the Application Program (AP), such control operations as connections/disconnections between NEAX2400 IMX-accommodate terminal (Dterm) and another, between a Dterm and a C.O. Line Outgoing/Incoming Trunk, etc. The SCF has several functions (FN), and explanations will be given in the following about “Basic Connecting Function (FN = 1) – Make Call (Automatic Answer)” which is one of the several functions. Note:The basic connection function is a function which automatically set a terminal into an outgoing connection status. Responding to a connection request from the AP, both the calling terminal number and the call destination number can be designated. NEAX2400 IMX Station Group Host Computer [Application Program (AP]
ND-70895 (E) CHAPTER 5 Page 63 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3.1.2 Using Conditions 1. Normal and abnormal operating sequences pertaining to the basic connection of the SCF are as described below. [Normal Sequence] (a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal. (b) If the calling terminal and the destination terminal are idle, the NEAX2400 IMX sends out Return Result to the AP, and places the calling terminal into an outgoing connection status and the destination terminal into ringing status. These are the basic functions. (c) When the destination terminal designated from the AP is a terminal in the NEAX2400 IMX and automatic answer is designated as the answer type, both the calling and destination terminals can be placed into speech status immediately from the status cited in (b) (After zip tone has been sent to both terminals, the terminals are placed into speech status.). Note that this service function is valid only when the destination terminal is in line selection wait status and also automatic answer is designated as the answer type. In other words, if the destination terminal is in a status other than line selection wait status, the call is to be answered manually. Further, this service function is valid only when the destination terminal is a station (D term: Voice) among the SCF Make Call designations. In other words, if the call destination is a trunk, this service function does not work. Destination TerminalCalling TerminalNEAX2400Computer (AP) SCF Activated Return Result Terminal Check Connection
CHAPTER 5 ND-70895 (E) Page 64 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services [Abnormal Sequence] (a) Upon receiving SCF start request from the AP, the NEAX2400 IMX judges the status (idle, busy, makebusy, etc.) of the designated calling terminal and destination terminal. (b) If the calling terminal and the destination terminal are in a status other than idle, the NEAX2400 IMX sends out Return Error to the AP. 2. Only digital multifunction telephone (D term Series E) can be designated as a calling terminal. Destination TerminalCalling TerminalNEAX2400Computer (AP) SCF Activated Return Error Terminal Check
ND-70895 (E) CHAPTER 5 Page 65 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3.1.3 Data Programming Assignment 1. ASYD (System Data) SYS1 INDEX 79 b6: 0 (OAI service is available) 2. AKYD (D term Key Data) Restrict a call origination from the prime line of the terminal of which answer type is designated as automatic answer S: Outgoing call from a prime line (0/1) 0/1: Allowed/Restricted Deletion 1. AKYD (D term Key Data) Cancel restriction on a call origination from the prime line of the terminal of which answer type is designated as automatic answer S: Outgoing call from a prime line (0/1) 0/1: Allowed/Restricted 2. ASYD (System Data) SYS1 INDEX 79 b6: 1 (OAI service is not available)
CHAPTER 5 ND-70895 (E) Page 66 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3.2 Call ID Notification (SMFN for ISDN) 3.2.1 Functional Outline This Call ID Notification function is an enhancement of both the Call Termination Notification and the Answer Notification among Call Status Monitor Facility Notification functions of the OAI system, and provides the User’s Application Processor for External Computer (UAP) with the caller’s information when call termination is to be notified about an incoming call from the Integrated Services Digital Network (ISDN) concerned. Likewise, when the called terminal has answered an incoming call, this function also provides the UAP with the ISDN caller’s information. 3.2.2 Using Conditions 1. Only when a call has terminated from the ISDN and when the call has been answered, SMFN message is sent out with the caller’s information added. Note, however, that caller’s information may not be added to the message depending on the restrictive conditions pertaining to the caller notification of the ISDN. 2. The number of digits for ISDN caller’s information is maximum 33 for the caller’s number and maximum 20 for call sub-address. 3. The SMFR cannot monitor ISDN terminal, and thus when a call has terminated to an ISDN terminal and the call has been answered, SMFN message is not sent out. NEAX2400 IMX Dterm SMFNISDN Station Group SET-UP Signal Single-Line Telephone UAP
ND-70895 (E) CHAPTER 5 Page 67 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 4. When an incoming call terminates from ISDN network, ISDN caller’s number information (subscriber’s number and sub-address) is provided from the central office in the following format. Subscriber number is maximum 33 digits, and the sub-address is maximum 20 digits, and they are separated by the separator “*” (OBH). 3.2.3 Data Programming 1. Assignment ASYD (System Data) SYS1 INDEX 79 b6: 0 (OAI service is not available) INDEX 241 b2: 1 (OAI Call Status Monitor Facility Notification is not in service) 2. Deletion ASYD (System Data) SYS1 INDEX 79 b6: 1 (OAI service is not available) INDEX 241 b2: 0 (OAI Call Status Monitor Facility Notification is not in service) ISDN Caller’s Number Information1 ≤n≤54 D C 1D C 2D C n D C n–1
CHAPTER 5 ND-70895 (E) Page 68 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3.3 MWL Control (SSF) STEP-1 3.3.1 Functional Outline This function allows the Application Program (AP) to provide a single-line telephone equipped with Message Waiting Lamp (MWL) or a Dterm with the following Message Waiting (MW) services by the OAI Service Set Facility (SSF). 1. MW Setting (Turning MW Lamp On) 2. MW Resetting (Flashing MW Lamp) 3. MW CANCEL (Turning MW Lamp Off) 4. LCD Display on each MW type Display contents: Message Waiting (MW) Voice Mail Module (VMM) Text Mail Module (TMM) Facsimile Mail Module (FMM) NEAX2400 IMX (Dterm)( Dterm) Single-Line Telephone Station Group Host Computer [Application Program (AP)] (W/MWL)
ND-70895 (E) CHAPTER 5 Page 69 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 3.3.2 Using Conditions 1. Normal and abnormal operating sequences pertaining to the basic connection of the SSFR are as described below. [Normal Sequence] [Abnormal Sequence] Terminal (Dterm)NEAX2400 IMXComputer (AP) SSFR Activated Return Result Received Information Analysis Service Set/Cancel Terminal (Dterm)NEAX2400 IMXComputer (AP) SSFR Activated Return Result Received Information Analysis
CHAPTER 5 ND-70895 (E) Page 70 Revision 1.0 OFFICE DATA DESIGN Procedure for Setting Office Data for OAI Services 2. This service cannot be used simultaneously with other MW control services (VMM/MCI: Message Center Interface/Message Waiting from Station, ATTCON and MAT). 3. The conditions for the telephone that controls MW are as follows. MW can be serviced only on a telephone equipped with MW lamp function. On a single-line telephone and/or D term, MW lamp display position is fixed. On a single-line telephone, MW lamp flashing cannot be controlled (ON/OFF only). MW lamp on/off/flashing, and LCD display can be controlled on a D term. (MW indication is available only on a Dterm equipped with the indicator.) D term can control only lamp flashing (LCD display cannot be controlled). 4. In the case of MW service by SSFR (Confirm-type < Computer→NEAX > Performer facility), the same kinds of display (MW, VMS) as those of MCI (Message Center Interface) are possible. 5. In the case of deletion of all the station data and all the type data, only the same data as those of MCI are deleted. MW service information for stations from the OAI Terminal Control Facility (TCF) are not deleted. 6. In the case of MW service by SSFR, lamp on/flashing/off is immediately indicated at the time of one station control. In the case of deletion of all the station data and all the type data, a delay time of maximum 196 seconds generates until the status of the terminal changes actually. 7. The system configuration for implementing this service is as illustrated below. Terminal NEAX2400 IMX DLC (D term) Single-Line Telephone with MWL TSW LC CPUIP Appli- cation Program Computer SSFR OAI (AP)