ND-70895 (E) CHAPTER 3 Page 21 Revision 1.0 INSTALLATION PROCEDURE OAI Software Installation 3. OAI Software Installation This section explains the installation procedure for adding the OAI software to the PBX in off-line operation. For more detailed information of program install procedure before the OAI application software install, see “Installation Manual”. [Operation Procedure] STEP 1: By using MEM_HDD command, save all data to the both HDDs. STEP 2: Make the Standard Service Software FD link with the OAI Option Service Software FD, and install it into the HDD. When OAI system is used in the Fusion Network (OAI Terminal Anywhere), link the ACD Option Service Software for “Agent Anywhere” with the above software FD and install it into all the nodes. (valid since the PBX software R8) STEP 3: Initialize the system (perform IPL, DM loading). PROGRAM=“LOAD” SYSTEM DATA=“OVERRIDE/LOAD” Note:When OAI system is used through the Fusion Network [valid since Series 7400 (Release 8) software], the UAP must be booted up after the confirmation of the establishment of the Fusion Link. STEP 4: Change system data written in DM. ASYD SYS1 INDEX31 - b0~b3: CM mounting capacity Normally assign “04”. Note 1 Note 2 Note 3 INDEX79 - b6=0 (OAI service is in service)Note 1 INDEX207 - b0 (IP in system0), b1 (IP in system1) Assign “1” to the corresponding bit for the IP accommodation. INDEX241- b2=1 (Call Processing Event Notification) Note 1 INDEX241- b3=1 (Details of SCF Error Notification)Note 1 Note 1: When OAI system is used in the Fusion Network, this data setting is necessary at the all nodes. Note 2:Reset the system after changing this data from 02H (normally assigned data value for the system without OAI service) to 04H. STEP 5: Assign the system data written in NDM. This data below are necessary when OAI system is used through the Fusion Network. ASYDN SYS1 INDEX514- NDM usage INDEX533- FPC of the node that provides VNDM (Normally, assign the FPC of the node that has the IP) Note 3:Assign “OG” for Series 7400 (Release 8) and later software.
CHAPTER 3 ND-70895 (E) Page 22 Revision 1.0 INSTALLATION PROCEDURE OAI Software Installation STEP 6: Assign the system data written in LDM. ASYDL SYS1 INDEX512: FPC of the self-node When OAI system is used through the Fusion Network, this data setting is necessary at each node in the network. INDEX513: 01 Hex (LDM usage) INDEX515~518 b0~b7: IP address (Hex) for PBX over external LAN Note 4 INDEX519~522 b0~b7: Subnet Mask (Hex) for PBX over external LANNote 4 INDEX523~526 b0~b7: Default Gateway Address for External LANNote 4 (This data is required when the Host is connected via gateway) INDEX864 - b0=1 (Built-in IP is provided) When OAI system is used in the Fusion Network (OAI Terminal Anywhere) [available since the Series 7400 (Release 8) software], assign “1” at the node that has the IP. INDEX864 b1 :Output the system message (4-R) when TCP-IP is normally disconnected. 0/1=Effective/Ineffective Note 4:If the MAT or SMDR has been connected with external LAN already, this data assignment is not necessary. STEP 7: Check the station-to-station connection and confirm no fault status occurs or system messages are output (such as cable connection fault, LCD display fault, memory alarm fault, abnormal interrupt etc.). STEP 8: Program the OAI office data. Also, program the Fusion data to make ACD service effective through Fusion network, if necessary. STEP 9: Save the DM into the HDD by using MEM_HDD.
ND-70895 (E) CHAPTER 3 Page 23 Revision 1.0 INSTALLATION PROCEDURE Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX 4. Upgrading OAI System from NEAX2400 ICS to NEAX2400 IMX The procedure for upgrading OAI System NEAX2400 ICS to NEAX2400 IMX is shown below. 4.1 Up Grading Procedure STEP 1: Stop the operation of the external computer by the appropriate procedure. STEP 2: Upgrade the PBX hardware following by the Upgrade Manual for the PBX. STEP 3: Upgrade the PBX software to install the software below. Assortment of software for NEAX2400 IMX Note 1 OAI Optional software STEP 4: Program the following OAI commands data again. ASYDL Note 2 STEP 5: Start Up the external computer Note 3 hardware and software of the external computer STEP 6: Perform the installation test. Note 1:This software is commonly used with all types of systems. Data Memory does not have to be changed. Note 2:For detail, see Section 3. “OAI Software Installation”. Note 3:This procedure is not necessary for the ACD system without MIS. For more information, see Section 2. “Cable Connections with External Computer”. The TCP Port number of the external computer has to be changed to “60030” for NEAX2400 IMX.
CHAPTER 3 ND-70895 (E) Page 24 Revision 1.0 This page is for your notes.
ND-70895 (E) CHAPTER 4 Page 25 Revision 1.0 CHAPTER 4 COMMANDS 1. General This chapter explains the commands that are used in the NEAX2400 IMX OAI System. The contents of this Chapter are outlined below. Configuration of Commands for OAI System This section explains the construction of each command. Commands This section explains the functions, parameters, and operating procedure of each command.
CHAPTER 4 ND-70895 (E) Page 26 Revision 1.0 COMMANDS Configuration of Commands for OAI System 2. Configuration of Commands for OAI System 2.1 Configuration of Commands The configuration of the commands in use in the NEAX2400 IMX OAI System is shown in Figure 4-1. Figure 4-1 Configuration of Commands of the NEAX2400 IMX OAI System Commands for BusinessCommands for OAI System ASYDL AKYD ARNP ASPAAADT ACNO AMNO AOAC AOKC LADT LCNOLMNO LOAC LOKC DFLN OAI System Operating Commands CommandsASYD ASYDN
ND-70895 (E) CHAPTER 4 Page 27 Revision 1.0 COMMANDS Commands 3. Commands This section explains the commands in used in the OAI System. 3.1 List of Commands Table 4-1 shows a list of commands in use in the OAI system. As for any command other than those in the list, refer to the Feature Programming Manual and Office Data Specification of the NEAX2400 IMX. Note 1:Each command marked with *is used for listing up the assigned data, and thus its explanation will be omitted. Note 2:For this command, refer to the Feature Programming Manual and Office Data Specification of the NEAX2400 IMX. Table 4-1 OAI System Command Table List ABBREV. COMMANDCOMMAND AADT Assignment of Announcement/Dictation Trunks ACNO Assignment of Conversion Number Data AKYD Assignment of Key Data for D term AMNO Assignment of Monitored Number AOAC Assignment of OAI Access Code AOKC Assignment of OAI Key Code ARNP Note 2Assignment of Reverse Numbering Plan Data ASPAAssignment of Specific Attendant Number ASYD ASYDN ASYDLAssignment of System Data DFLN Display of Location Free Numbering LADT Note 1List Up of Announcement/Dictation Trunks LCNO Note 1List Up of Conversion Number Data LMNO Note 1List Up of Monitored Number LOAC Note 1List Up of OAI Access Code LOKC Note 1List Up of OAI Key Code
CHAPTER 4 ND-70895 (E) Page 28 Revision 1.0 COMMANDS Commands 3.2 Outline of Commands for OAI System The interrelation among the commands to be used in the OAI System is illustrated in Figure 4-2. Figure 4-2 Interrelation among OAI System Commands AKYD : This command is used to assign the function key codes (For OAI: 34 ~ 47) to the function key positions of the Dterm. AOKC : This command is used to assign the meaning of OAI key code assigned by AKYD command. Note 1:Function key codes 34 ~ 47 respectively correspond to OAI key codes (1 ~ 14). AOAC : This command is used to assign the access code/operation code for the designated facility. This command is used only when the Facility Kind (F-KIND) has been set to “3” (Open Appli- cation Interface) by AOKC command. Note 2:Parameters OAI Key Code (KEY-CODE), Facility Kind (F-KIND), and Operation Code (OP-CODE) are determined by the application software to be used at each office. 3.3 Items to Be Explained by Each Command Each command is described by the following items. Command : The name implies the command and its functions. (1) Functions : This item outlines the command functions. (2) Precaution : This item explains precaution for use of the command. (3) Parameters : This item explains the meaning of the information (parameters) of the data of the command. (4) Related Commands : This item specifies other command or commands pertaining to the same data, assignment/deletion/change/display/list up of the details of that specific data. NEAX2400 IMX DLC/ELC AKYD AOKC AOACASDT AKYDExternal Computer ASYD ARNPIPCommand Name : Commands for NEAX2400 ASYD ARNP ASDT AKYD: Assignment of System Data : Assignment of Reverse Numbering Plan Data : Assignment of Station Data : Assignment of Dterm Key Data
ND-70895 (E) CHAPTER 4 Page 29 Revision 1.0 COMMANDS AADT AADT: Assignment of Announcement/Dictation Trunks 1. Functions This command is used to assign/delete Announcement Trunks or Dictation Trunks. 2. Precaution When changing the LENS of the currently assigned Announcement/Dictation Trunks, delete the assigned data first by this command, and then change the LENS by Assignment of Trunk Data (ATRK) command. It must be remembered that, if the LENS data are deleted first by ATRK command by mistake, the data currently assigned by this AADT command are automatically deleted. 3. Parameters TYPE : Announcement Trunk (ANT), Dictation Trunk (DCT) NO. : Message Number D : Disconnect Timer (0/1); Valid when TYPE = ANT 0: Impossible (Repeat) 1: Possible (Disconnect by MSGT) MSGT : Message Timer (2 ~ 120 sec., 2-sec. interval when shorter than 30 sec., 8-sec. interval when longer than 30 sec.) CP : Connection Pattern Note 0: Multiple Connection 1: Single Connection WAIT : Waiting Timer (0~30 sec., 2-sec. interval) Note Note: Available only when the system data is programmed that the DAT control function is available (ASYD, SYS1, INDEX449, b2=1). CNT : Number of ANT/DCT Trunks assigned or to be assigned (1 ~ 8) RT : R o u t e N u m b e r TK : Trunk Number 4. Related Commands List Up : LADT
CHAPTER 4 ND-70895 (E) Page 30 Revision 1.0 COMMANDS AADT Announcement/Dictation Trunk Data Assignment Table Disconnect Timer 0 = Impossible 1 = Possible TRUNK TYPE (TYPE) ANT/DCTMESSAGE NO. (NO) MESSAGE TIMER (MSGT) 2 ~ 120DISCON- NECT TIMER (D) 0/1CONNEC- TION PATTERN (CP) 0/1WA I T I N G TIMER (WAIT) 0 ~ 30ANT/DCT ASSIGNED NO. OF TRUNKS (CNT) 1 ~ 8ROUTE NUMBER (RT)TRUNK NUMBER (TK) ANT 1 ~ 58DCT 1 ~ 5 || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | || || | | | | ||