    							ND-70895 (E) CHAPTER 4
     Page 41
    Revision 1.0
    COMMANDS
    AOKC
    Table of Operation Codes
    OPERATION CODE REMARKS
    128 (0080): MSF
    191 (00BF): MSFOAI
    (Terminal Mode Set Facility)
    192 (00C0): TMF
    255 (00FF): TMFOAI
    (Terminal Multiple Information Transfer Facility) 
    						
    							CHAPTER 4 ND-70895 (E)
    Page 42
    Revision 1.0
    COMMANDS
    ASPA
    ASPA:  Assignment of Specific Access Code
    24. Functions
    This command is used to assign/delete/display each data which respectively determines what kind of
    service should be executed and/or which route should be used, etc. when a special access code, C.O. line
    access code or Tie-Line access code has been dialed.
    25. Precaution
    (a) For the details of special access code data, refer to the description of ASPA command in the Feature 
    Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will 
    be limited only to the items pertaining to the OAI System.
    (b) For assigning OAI Dial Number Batch Transfer (SRV = SSCA, SIDA = 69), be sure to set the 
    number of digits (max. 3 digits) of the OAI access code to Necessary Number of Digits (NND).
    26. Parameters
    SIDA: Service Feature Index A (69)
    69: OAI Dial Number Batch Transfer (TMF)
    Note:For the details of other parameters, refer to the description of ASPA command in the Office Data
    Specification for the NEAX2400 IMX.
    Specific Access Code Data Assign Table
    The Office Data Sheets of this ASPA command are attached only to the pages pertaining to the data to be
    assigned in the OAI System. Replace these Office Data Sheets with those for ASPA command of the
    NEAX2400 IMX.
    Table 4-2 Supplementary Service Codes
    TENANT 
    NUMBER 
    (TN)ACCESS 
    CODE 
    (ACC)CONNECTION 
    STATUS INDEX 
    (CI)KIND OF 
    SERVICE
    (SRV)SERVICE FEA-
    TURE INDEX A 
    (SIDA)REMARKS
    1 ~ 311 ~ 3
    DIGITSN/H/B SSCA
    NNormal
    SSCA 69OAI Dial Number Batch Trans-
    fer (TMF)
    H Hooking 
    						
    							ND-70895 (E) CHAPTER 4
     Page 43
    Revision 1.0
    COMMANDS
    ASYD
    ASYD:  Assignment of System Data
    27. Functions
    This command is used to assign System Data 1, 2, and 3.
    28. Precaution
    For the details of the system data, refer to the description of ASYD command in the Office Data
    Specification for the NEAX2400 IMX. 
    						
    							CHAPTER 4 ND-70895 (E)
    Page 44
    Revision 1.0
    COMMANDS
    ASYD
    System Data Assign Table (1)
    The Office Data Sheets of this ASYD command are provided only for the data to be assigned in the OAI System.
    Use these Office Data Sheets together with those for ASYD command of the NEAX2400 IMX.
    SYSTEM 
    DATA  
    TYPE
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1190b
    0
    Not used 0b
    1
    0b2
    0b3
    0b4
    b5
    Call Event Transfer Facility (ETF) Call Base Table Save and ETF Ser-
    vice is provided
    0/1: Unrequired/Required (3 hours)
    0b
    6Fixed to 0
    0b
    7Not used
    28b
    0Miscellaneous Timer Counter
    (MTC)
    (00 ~ 1F Hex)Message sending Guard 
    Timer for Message Center 
    Interface.
    Guard Time after sending 
    data to Message Center:
    Time Value Setting is 
    (MTC) × 128 msec.
    (When this data is 00 Hex, 
    Timer value is 0 msec.) b
    1
    b2
    b3
    b4
    b5
    Be sure to set “1” when using SSFR (FN = 5, SRID = 0)
    MCI Message Waiting Lamp Function
    0/1: Not provided/Provided
    0b
    6Not used
    0b
    7 
    						
    							ND-70895 (E) CHAPTER 4
     Page 45
    Revision 1.0
    COMMANDS
    ASYD
    System Data Assign Table (1)
    SYSTEM 
    DATA 
    TYPE
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    131 040b
    0Equipped capacity of the Common Memory (CM): 1 ~ 4 Mbyte
    Assign “6” Hex. when FLF Fusion service is used.
    (Available since the PBX software R8) 0b
    1
    1b2
    0b3
    0b4
    Not used 0b5
    0b6
    0b7
    47b
    0Traffic Measurement Indication
    0/1 = CCS Indication/Erlang Indication
    b
    1
    Timer Internal Between Messages (TCFI) Timer
    b
    2
    0b3
    Display for TCFD
    0/1 = MSG/Last input
    0 = Normal assignment
    0b
    4SCF(FN = 127) Tone Control
    0/1 = Invalid/Valid
    0b
    5Not used
    0b
    6
    b7Traffic Measurement for Terminal and Route Traffic (ATRF)
    0/1 = Out/In service
    b2b1b2b1
    0 0 = 2 seconds 1 1 = Application Dependent
    0 1 = 4 seconds (Standard Assignment)
    1 0 = 8 seconds 
    						
    							CHAPTER 4 ND-70895 (E)
    Page 46
    Revision 1.0
    COMMANDS
    ASYD
    170b
    0Called Number Display when forwarding to Attendant Console
    0/1 : Out/In service
    b
    1Flashing display of Line Lockout on Attendant Console BLF
    0/1 : In service/Out
    b
    2
    Route No. Display on Attendant Console
    b
    3
    0b4One digit dialing instead of SHF (DP TEL only)
    0/1 : Not required/Required
    b
    5
    Priority order for answering via ANSWER key
    0 : Priority according to Type of Call
    1 : Priority according to the order call termination
    b
    6Connection of SCF Announcement
    1 : available
    b
    7
    Send Warning Tone to interrupted parties when Executive Right of 
    Way service is in operation
    0/1 : Required/Not required
    77b
    0Day/Night Mode Change via the ATTCON Handset Jack
    0/1: Not required/Required
    0b
    1Not used
    b
    2MW Refresh 0/1 :Not required/Required
    b
    3Service Module Interface 0/1: Not required/Required
    1b
    4Module in which PFT card is mounted
    PIM (Always assign “11”)
    1b
    5
    0b6Not used
    0b
    7
    System Data Assign Table (1)
    SYSTEM 
    DATA 
    TYPE
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    b3b200:
    TN RT TRKb
    3b201:
    RT TRK 
    						
    							ND-70895 (E) CHAPTER 4
     Page 47
    Revision 1.0
    COMMANDS
    ASYD
    Note 1:
    When the bit is set to “0” the bottom line display of the Message Waiting Enhance Display Service becomes
    invalid.
    Note 2:If, at an office in service with this bit set to “1” (No OAI Service is Provided), the bit value is to be changed
    to “0” (OAI Service is Provided).
    1781b
    0
    Calling and Intermediate Station Number indication
    (Dterm and ATTCON)
    0/1: Out/In service
    (Always assign “1”)
    1b
    1
    Kind of Service Class indication (Dterm)
    0/1: Out/In service
    (Always assign “1”)
    0b
    2Not used
    b
    3Station Number Display with 8-digit Name Display
    0/1: Out/In service
    0b
    4Fixed to “0”
    b
    5
    Name Display Service
    0/1: Not to be serviced/To be serviced
    (FLF: Free Location Facility)
    0b
    6Not used
    0b
    7
    79b
    0Line Preference Service via AKYD
    0/1: Out/In service
    0b
    1Not used
    b
    2Split Call Forwarding Service
    0/1: Out/In service
    0b
    3Not used
    b
    4Zip tone control at the time of SC F:Monitor connection
    0/1: Not to be controlled/To be controlled
    b
    5Name Display Service for Calling Party Only
    0/1: Out/In service Note 1
    b
    6OA I S er v ice
    0/1: In/Out service Note 2
    0b
    7Not used
    System Data Assign Table (1)
    SYSTEM 
    DATA 
    TYPE
    (SYS)SYSTEM 
    DATA 
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    							CHAPTER 4 ND-70895 (E)
    Page 48
    Revision 1.0
    COMMANDS
    ASYD
    System Data Assign Table (1)
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1800b
    0Not used
    b
    1Message Reminder Service-Key used for Message Deletion (Dterm)
    0/1 = # key/* key
    b
    2Fixed to “0”
    b
    3
    TCF (I) : LCD Display Control
    0: Top Line 16-digits display control
    1: Second Line 16-digits display control
    0b
    4
    Not used 0b5
    0b6
    0b7 
    						
    							ND-70895 (E) CHAPTER 4
     Page 49
    Revision 1.0
    COMMANDS
    ASYD
    System Data Assign Table (1)
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT
    1 207b
    0No. 0 CPU Mounted Status of IP00/1:Not mounted/Mounted
    b
    1No. 1 CPU Mounted Status of IP00/1:Not mounted/Mounted
    0b
    2
    Not used 0b
    3
    0b4
    0b5
    0b6
    0b7 
    						
    							CHAPTER 4 ND-70895 (E)
    Page 50
    Revision 1.0
    COMMANDS
    ASYD
    Note:
    This timer data is exclusively for the function for batch transfer (TMF) of OAI dial number from a single-
    line telephone set. Therefore, this timer data is invalid for TMF from a Dterm.
    1241b
    0Data Port Chime Control by SCF
    0/1: To be controlled/Not to be controlled
    b
    1Name Display Service
    0/1: 8 digits/16 digits
    b
    2Call Status Monitor Facility Notification (SMFN)
    0/1: Invalid/Valid
    b
    3SCF Return Error Detail Notification
    0/1: Invalid/Valid
    0b
    4
    Not used 0b5
    0b6
    0b7
    251b
    0Miscellaneous Timer Counter (MTC)
    1 ~ FValue for OAI Host 
    Computer Answer Wait 
    Timer (TC) × (MTC) is to 
    be set.
    When the data is 00 (Hex), 
    the timer value becomes 8 
    minutes. Note b
    1
    b2
    b3
    b4Timer Class (TC)
    0: – 3: 2 sec.6:–
    1: 64 msec. 4: 30 sec.7:–
    2: – 5: – b
    5
    b6
    0b7Not used
    System Data Assign Table (1)
    SYSTEM
    DATA
    TYPE
    (SYS)SYSTEM 
    DATA  
    INDEX 
    (INDEX)
    0 – 255DATA
    (DATA)
    00– FF
    (Hex)BIT 
    CORRE-
    SPONDING 
    DATA SYSTEM DATA CONTENTS
    DATA
    0/1BIT 
    						
    All NEC manuals Comments (0)