ND-70895 (E) CHAPTER 4 Page 41 Revision 1.0 COMMANDS AOKC Table of Operation Codes OPERATION CODE REMARKS 128 (0080): MSF 191 (00BF): MSFOAI (Terminal Mode Set Facility) 192 (00C0): TMF 255 (00FF): TMFOAI (Terminal Multiple Information Transfer Facility)
CHAPTER 4 ND-70895 (E) Page 42 Revision 1.0 COMMANDS ASPA ASPA: Assignment of Specific Access Code 24. Functions This command is used to assign/delete/display each data which respectively determines what kind of service should be executed and/or which route should be used, etc. when a special access code, C.O. line access code or Tie-Line access code has been dialed. 25. Precaution (a) For the details of special access code data, refer to the description of ASPA command in the Feature Programming Manual and Office Data Specification for the NEAX2400 IMX. Explanations here will be limited only to the items pertaining to the OAI System. (b) For assigning OAI Dial Number Batch Transfer (SRV = SSCA, SIDA = 69), be sure to set the number of digits (max. 3 digits) of the OAI access code to Necessary Number of Digits (NND). 26. Parameters SIDA: Service Feature Index A (69) 69: OAI Dial Number Batch Transfer (TMF) Note:For the details of other parameters, refer to the description of ASPA command in the Office Data Specification for the NEAX2400 IMX. Specific Access Code Data Assign Table The Office Data Sheets of this ASPA command are attached only to the pages pertaining to the data to be assigned in the OAI System. Replace these Office Data Sheets with those for ASPA command of the NEAX2400 IMX. Table 4-2 Supplementary Service Codes TENANT NUMBER (TN)ACCESS CODE (ACC)CONNECTION STATUS INDEX (CI)KIND OF SERVICE (SRV)SERVICE FEA- TURE INDEX A (SIDA)REMARKS 1 ~ 311 ~ 3 DIGITSN/H/B SSCA NNormal SSCA 69OAI Dial Number Batch Trans- fer (TMF) H Hooking
ND-70895 (E) CHAPTER 4 Page 43 Revision 1.0 COMMANDS ASYD ASYD: Assignment of System Data 27. Functions This command is used to assign System Data 1, 2, and 3. 28. Precaution For the details of the system data, refer to the description of ASYD command in the Office Data Specification for the NEAX2400 IMX.
CHAPTER 4 ND-70895 (E) Page 44 Revision 1.0 COMMANDS ASYD System Data Assign Table (1) The Office Data Sheets of this ASYD command are provided only for the data to be assigned in the OAI System. Use these Office Data Sheets together with those for ASYD command of the NEAX2400 IMX. SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1190b 0 Not used 0b 1 0b2 0b3 0b4 b5 Call Event Transfer Facility (ETF) Call Base Table Save and ETF Ser- vice is provided 0/1: Unrequired/Required (3 hours) 0b 6Fixed to 0 0b 7Not used 28b 0Miscellaneous Timer Counter (MTC) (00 ~ 1F Hex)Message sending Guard Timer for Message Center Interface. Guard Time after sending data to Message Center: Time Value Setting is (MTC) × 128 msec. (When this data is 00 Hex, Timer value is 0 msec.) b 1 b2 b3 b4 b5 Be sure to set “1” when using SSFR (FN = 5, SRID = 0) MCI Message Waiting Lamp Function 0/1: Not provided/Provided 0b 6Not used 0b 7
ND-70895 (E) CHAPTER 4 Page 45 Revision 1.0 COMMANDS ASYD System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 131 040b 0Equipped capacity of the Common Memory (CM): 1 ~ 4 Mbyte Assign “6” Hex. when FLF Fusion service is used. (Available since the PBX software R8) 0b 1 1b2 0b3 0b4 Not used 0b5 0b6 0b7 47b 0Traffic Measurement Indication 0/1 = CCS Indication/Erlang Indication b 1 Timer Internal Between Messages (TCFI) Timer b 2 0b3 Display for TCFD 0/1 = MSG/Last input 0 = Normal assignment 0b 4SCF(FN = 127) Tone Control 0/1 = Invalid/Valid 0b 5Not used 0b 6 b7Traffic Measurement for Terminal and Route Traffic (ATRF) 0/1 = Out/In service b2b1b2b1 0 0 = 2 seconds 1 1 = Application Dependent 0 1 = 4 seconds (Standard Assignment) 1 0 = 8 seconds
CHAPTER 4 ND-70895 (E) Page 46 Revision 1.0 COMMANDS ASYD 170b 0Called Number Display when forwarding to Attendant Console 0/1 : Out/In service b 1Flashing display of Line Lockout on Attendant Console BLF 0/1 : In service/Out b 2 Route No. Display on Attendant Console b 3 0b4One digit dialing instead of SHF (DP TEL only) 0/1 : Not required/Required b 5 Priority order for answering via ANSWER key 0 : Priority according to Type of Call 1 : Priority according to the order call termination b 6Connection of SCF Announcement 1 : available b 7 Send Warning Tone to interrupted parties when Executive Right of Way service is in operation 0/1 : Required/Not required 77b 0Day/Night Mode Change via the ATTCON Handset Jack 0/1: Not required/Required 0b 1Not used b 2MW Refresh 0/1 :Not required/Required b 3Service Module Interface 0/1: Not required/Required 1b 4Module in which PFT card is mounted PIM (Always assign “11”) 1b 5 0b6Not used 0b 7 System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT b3b200: TN RT TRKb 3b201: RT TRK
ND-70895 (E) CHAPTER 4 Page 47 Revision 1.0 COMMANDS ASYD Note 1: When the bit is set to “0” the bottom line display of the Message Waiting Enhance Display Service becomes invalid. Note 2:If, at an office in service with this bit set to “1” (No OAI Service is Provided), the bit value is to be changed to “0” (OAI Service is Provided). 1781b 0 Calling and Intermediate Station Number indication (Dterm and ATTCON) 0/1: Out/In service (Always assign “1”) 1b 1 Kind of Service Class indication (Dterm) 0/1: Out/In service (Always assign “1”) 0b 2Not used b 3Station Number Display with 8-digit Name Display 0/1: Out/In service 0b 4Fixed to “0” b 5 Name Display Service 0/1: Not to be serviced/To be serviced (FLF: Free Location Facility) 0b 6Not used 0b 7 79b 0Line Preference Service via AKYD 0/1: Out/In service 0b 1Not used b 2Split Call Forwarding Service 0/1: Out/In service 0b 3Not used b 4Zip tone control at the time of SC F:Monitor connection 0/1: Not to be controlled/To be controlled b 5Name Display Service for Calling Party Only 0/1: Out/In service Note 1 b 6OA I S er v ice 0/1: In/Out service Note 2 0b 7Not used System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT
CHAPTER 4 ND-70895 (E) Page 48 Revision 1.0 COMMANDS ASYD System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1800b 0Not used b 1Message Reminder Service-Key used for Message Deletion (Dterm) 0/1 = # key/* key b 2Fixed to “0” b 3 TCF (I) : LCD Display Control 0: Top Line 16-digits display control 1: Second Line 16-digits display control 0b 4 Not used 0b5 0b6 0b7
ND-70895 (E) CHAPTER 4 Page 49 Revision 1.0 COMMANDS ASYD System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT 1 207b 0No. 0 CPU Mounted Status of IP00/1:Not mounted/Mounted b 1No. 1 CPU Mounted Status of IP00/1:Not mounted/Mounted 0b 2 Not used 0b 3 0b4 0b5 0b6 0b7
CHAPTER 4 ND-70895 (E) Page 50 Revision 1.0 COMMANDS ASYD Note: This timer data is exclusively for the function for batch transfer (TMF) of OAI dial number from a single- line telephone set. Therefore, this timer data is invalid for TMF from a Dterm. 1241b 0Data Port Chime Control by SCF 0/1: To be controlled/Not to be controlled b 1Name Display Service 0/1: 8 digits/16 digits b 2Call Status Monitor Facility Notification (SMFN) 0/1: Invalid/Valid b 3SCF Return Error Detail Notification 0/1: Invalid/Valid 0b 4 Not used 0b5 0b6 0b7 251b 0Miscellaneous Timer Counter (MTC) 1 ~ FValue for OAI Host Computer Answer Wait Timer (TC) × (MTC) is to be set. When the data is 00 (Hex), the timer value becomes 8 minutes. Note b 1 b2 b3 b4Timer Class (TC) 0: – 3: 2 sec.6:– 1: 64 msec. 4: 30 sec.7:– 2: – 5: – b 5 b6 0b7Not used System Data Assign Table (1) SYSTEM DATA TYPE (SYS)SYSTEM DATA INDEX (INDEX) 0 – 255DATA (DATA) 00– FF (Hex)BIT CORRE- SPONDING DATA SYSTEM DATA CONTENTS DATA 0/1BIT