NDA-24234 CHAPTER 3 Page 51 Revision 3.0 INSTALLATION PROCEDURE This NAP explains the procedure for securing the Base Unit onto the floor directly or using special stand. 1. INSTALLING THE BASE UNIT DIRECTLY ONTO THE FLOOR Figure 004-1 Mounting the Base Unit on an Ordinary Floor NAP-200-004 Sheet 1/3 Installation of the Base Unit START Securing the Base Unit Secure the Base Unit onto the floor as per Figure 004-1 and 004-2. When the floor elevation is in use, secure the Base Unit by referring to...
Page 82
CHAPTER 3 NDA-24234 Page 52 Revision 3.0 INSTALLATION PROCEDURE Figure 004-2 Mounting the Base Unit on a Free-Access or Computer Floor Figure 004-3 Mounting the Base Unit on a Free-Access or Computer Floor via Elevation NAP-200-004 Sheet 2/3 Installation of the Base Unit BOLT BASE UNIT FREE-ACCESS FLOOR FLAT WASHER COMPRESSED PIPE FLAT WASHER CONCRETE FLOOR ANCHOR BOLT Example: The floor elevation is higher than 150 mm (5.9 inches). FLOOR ELEVATION BASE UNIT FREE-ACCESS FLOOR
Page 83
NDA-24234 CHAPTER 3 Page 53 Revision 3.0 INSTALLATION PROCEDURE 2. INSTALLING THE BASE UNIT USING A SPECIAL STAND Figure 004-4 Setting the BASEU via Special Stand NAP-200-004 Sheet 3/3 Installation of the Base Unit START Securing the Base Unit Secure the Base Unit onto the special stand as per Figure 004-4. Level Check Check the level of the Base Unit. If necessary, adjust the level by inserting spacers beneath the Base Unit. END LOCK WASHERBOLT PLAIN WASHERBASEU SPECIAL STAND
Page 84
CHAPTER 3 NDA-24234 Page 54 Revision 3.0 INSTALLATION PROCEDURE 1. MOUNTING OF UNITS AND MODULES Figure 005-1 Procedure for Mounting Units and Modules NAP-200-005 Sheet 1/16 Mounting of Units and Modules START ENDMounting of Modules, FAN BOX and TOPUMount modules, FAN BOX and TOPU for each cabinet, by referring to the Figure 005-1. (TOPU) Tighten these screws. Do the same at the rear side, too. (PIM3) Tighten these screws. Do the same at the rear side, too. (PIM2) Tighten these screws. Do the same at...
Page 85
NDA-24234 CHAPTER 3 Page 55 Revision 3.0 INSTALLATION PROCEDURE 2. INSTALLATION OF FANU Location of FANU (PZ-M369 and three electronic FANs) is shown in Figure 005-2. Depending on your system con- figuration, mount the FANU in the proper position. Figure 005-2 Locations of FANU NAP-200-005 Sheet 2/16 Mounting of Units and Modules / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / NECNEAX 2400 IMSTOPU NECNEAX 2400 IMSTOPU FAN...
Page 86
CHAPTER 3 NDA-24234 Page 56 Revision 3.0 INSTALLATION PROCEDURE 3. PROCEDURE FOR FANU ON THE TOPU When any IMG is configured by two PIMs or less, the FANU is mounted as shown in Figure 005-3. Because the FANU is already mounted on the TOPU of the cabinet, perform STEP 4 through STEP 7 only, excepting a special case (STEP 1 through STEP 3 are not required in the normal cases). STEP 1: Referring to Figure 005-3, mount the three FANs onto the FAN Mounting Plate. Then, fasten every four screws. STEP 2:...
Page 87
NDA-24234 CHAPTER 3 Page 57 Revision 3.0 INSTALLATION PROCEDURE STEP 4: Fix a FAN fuse (5.0A) onto the PZ-M369. Figure 005-4 Attachment of FAN Fuse (PZ-M369) STEP 5: Connect the FAN cables as shown in Figure 005-5 and Figure 005-6. STEP 6: Lastly, attach the Top Cover onto the TOPU of the cabinet. Then, fasten the four screws (refer to Fig- ure 005-7). Note:The procedures, STEP 4 through STEP 6, must be performed at each PBX cabinet adopting 1-PIM or 2- PIM configuration. NAP-200-005 Sheet 4/16 Mounting...
Page 88
CHAPTER 3 NDA-24234 Page 58 Revision 3.0 INSTALLATION PROCEDURE Figure 005-5 Cable Connections for FANU on TOPU NAP-200-005 Sheet 5/16 Mounting of Units and Modules PBX NECNEAX 2400 IMS NEAX 2400 IMSNEC . .. . .. TH0 TH1 TH2 FAN FC0 FC1 FC2 TALM0 FA NNote 1 Note 2 TALM PZ-M369 THM TOPU FANU TOPU (Top View) ATTENTIONContents Static Sensitive Handling Precautions Required Note 1:For details on the “FA N” connector (PIM backplane), refer to Figure 005-6. Note 2:For details on the “TALM” connector (TOPU...
Page 89
NDA-24234 CHAPTER 3 Page 59 Revision 3.0 INSTALLATION PROCEDURE Figure 005-6 Connection of “FA N” Connector Cable (TOPU-PIM) NAP-200-005 Sheet 6/16 Mounting of Units and Modules PBXTOPU PIM (FAN) (FAN) TALM1 TALM0 TH1 TH0 FC0 FC1 FC2 FAN PZ-M369 ATTENTIONContents Static Sensitive Handling Precautions Required TH2ON OFF Auto
Page 90
CHAPTER 3 NDA-24234 Page 60 Revision 3.0 INSTALLATION PROCEDURE Figure 005-7 Attachment of the Top Cover NAP-200-005 Sheet 7/16 Mounting of Units and Modules NEAX 2400 IMSNEC Top Cover TOPU PIM Mount the Top Cover onto the TOPU. Then, fasten the four screws by using the Phillips screwdriver.