Home > NEC > Communications System > NEC Neax 2400 Imx Installation Manual

NEC Neax 2400 Imx Installation Manual

Here you can view all the pages of manual NEC Neax 2400 Imx Installation Manual. The NEC manuals for Communications System are available online for free. You can easily download all the documents as PDF.

Page 111

NDA-24234 CHAPTER 3
Page 81
Revision 3.0
INSTALLATION PROCEDURE
4. BRANCHING OF POWER CABLES
NAP-200-008
Sheet 10/13
Connection of Power and Ground 
Cables from the Power Equipment
START
Stripping Main and Branch Cable Referring to Figure 008-8, strip insulation coating 
with an electrician’s knife. Avoid damage to the 
conductor during the stripping process.
Inserting  of  Cables  into  Terminal Insert the stripped main wire and branch wire into the 
terminal as shown in Figure 008-9.
Clamping for...

Page 112

CHAPTER 3 NDA-24234
Page 82
Revision 3.0
INSTALLATION PROCEDURE
Figure 008-8  Stripped Length of Main and Branch Cable
NAP-200-008
Sheet 11/13
Connection of Power and Ground 
Cables from the Power Equipment
Table 008-1  Stripped Length
APPLICABLE TERMINALSTRIPPED MAIN-WIRE LENGTH I
1
[inch (mm)]STRIPPED MAIN-WIRE LENGTH I
2
[inch (mm)]
T-20 Approx. 1.2 (28) Approx. 1.0 (24)
T-26 1.3 (32) 1.2 (28)
T-44 1.5 (37) 1.3 (33)
T-60 1.6 (40) 1.5 (36)
T-76 1.7 (42) 1.6 (39)
T-98 1.8 (44) 1.7 (41)
T-122 1.7–1.9...

Page 113

NDA-24234 CHAPTER 3
Page 83
Revision 3.0
INSTALLATION PROCEDURE
Figure 008-9  Inserting of Cables into Terminal
Figure 008-10  Clamping for Branch Jointing
NAP-200-008
Sheet 12/13
Connection of Power and Ground 
Cables from the Power Equipment
1/8 inch (1 - 2 mm)
BRANCH 
CABLEMAIN CABLE
BEND PRIOR TO INSERTION
T TYPE 
TERMINAL
Note:Prevent the wires from slipping out of the clamp ter-
minal by holding them firmly.
Check the indication of the pressure regulator.
Operate the pressure release lever to...

Page 114

CHAPTER 3 NDA-24234
Page 84
Revision 3.0
INSTALLATION PROCEDURE
Figure 008-11  Taping
Figure 008-12  Covering
NAP-200-008
Sheet 13/13
Connection of Power and Ground 
Cables from the Power Equipment
Note:Taping should be done in two rounds with the tape
overlapping half the tape width.
INSULATION TAPE
4-1.2 in (10 - 30 mm) More than.4 in (10 mm)
INSULATION COVER 

Page 115

NDA-24234 CHAPTER 3
Page 85
Revision 3.0
INSTALLATION PROCEDURE
This NAP explains the following work items:
Extraction of Mounted Circuit Cards
Mounting of Circuit Cards
Setting of Switch Positions on Circuit Cards
Installation of CPR
1. PRECAUTIONS
1.1. Protection Against Static Electricity
When setting switches on circuit cards, use a Portable Field Service Grounding Kit in order to prevent damage
to static-sensitive components.
Example:    3M Model 8012, consists of:
2 
× 2 VELOSTAT 
® Wo r k  M...

Page 116

CHAPTER 3 NDA-24234
Page 86
Revision 3.0
INSTALLATION PROCEDURE
2. EXTRACTION OF MOUNTED CIRCUIT CARDS
NAP-200-009
Sheet 2/11
Setting of Switch Positions and 
Mounting of Circuit Cards
START
Remove the Card Stopper Referring to Figure 009-1, remove the card stopper 
from the module.
Extract Circuit Cards Referring to Figure 009-2, pull the card puller tabs 
in the direction indicated by the arrow. The card 
will release from the connector and can then be 
removed.
Pull the card out about 50 mm (2 inches)...

Page 117

NDA-24234 CHAPTER 3
Page 87
Revision 3.0
INSTALLATION PROCEDURE
Figure 009-1  Removal of Card Stopper
NAP-200-009
Sheet 3/11
Setting of Switch Positions and 
Mounting of Circuit Cards
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
CARD STOPPER
PAN HEAD SCREW (M3, 8mm (.3 inches) length)
SPRING WASHER (M3)
PLAIN WASHER (M3)
Remove the card stopper from the 
module using a phillips-head screwdriver.(PL-C.P.l. MS3815BF) 

Page 118

CHAPTER 3 NDA-24234
Page 88
Revision 3.0
INSTALLATION PROCEDURE
3. MOUNTING OF CIRCUIT CARDS
NAP-200-009
Sheet 4/11
Setting of Switch Positions and 
Mounting of Circuit Cards
START
Unpacking the Circuit Cards Unpack each circuit card and remove it from its 
polyethylene bag.
Clean the connector portion of the 
Circuit CardsWipe the connector portion clean using a soft cloth 
moistened with pure trichloroethylene or methanol 
(medical alcohol). Make sure that no lint or dust 
remains on the connector...

Page 119

NDA-24234 CHAPTER 3
Page 89
Revision 3.0
INSTALLATION PROCEDURE
4. SETTING OF SWITCH POSITIONS ON CIRCUIT CARDS
NAP-200-009
Sheet 5/11
Setting of Switch Positions and 
Mounting of Circuit Cards
START
Extracting the Circuit Cards from the 
ModuleExtract one circuit card requiring switch setting from 
the module.
Place the extracted card onto the anti-static sheet.
Perform switch setting Set the required switches according to the Switch 
Setting Sheets in the Circuit Card Manual.
Mounting of Circuit Cards...

Page 120

CHAPTER 3 NDA-24234
Page 90
Revision 3.0
INSTALLATION PROCEDURE
NAP-200-009
Sheet 6/11
Setting of Switch Positions and 
Mounting of Circuit Cards
AT T E N T I O NContents
Static Sensitive
Handling
Precautions Required
About 50 mm 
(2 inches)
About 50 mm 
(2 inches)
CIRCUIT 
CARDS
CARD 
PULLER 
TAB
Figure 009-2  Extraction of Circuit CardsFigure 009-3  Circuit Card Mounting (Partial Insertion) 