Page 51

NDA-24234 CHAPTER 2
Page 21
Revision 3.0
INSTALLATION DESIGN
Figure 2-9   Face Layout of IMG2, 3 (Multiple IMG Configuration)
PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX)
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413...

Page 52

CHAPTER 2 NDA-24234
Pag e 22
Revision 3.0
INSTALLATION DESIGN
9.2 Circuit Card Locations
This section explains the main function of controlling circuit cards on a module basis. For more detailed infor-
mation on each card, please refer to the NEAX2400 IMX Circuit Card Manual.
Figure 2-10   Controlling Circuit Cards in LPM
Table 2-4  Controlling Circuit Cards in LPM
Slot No. Circuit Card Symbol Functions, Mounting Conditions
02, 03 PH-IO24 IOC 
(Input/
Output 
Controller)This circuit card supplies the...

Page 53

NDA-24234 CHAPTER 2
Page 23
Revision 3.0
INSTALLATION DESIGN
Figure 2-11   Controlling Circuit Cards in PIM 0 (Single IMG Configuration Only)
Table 2-5  Controlling Circuit Cards in PIM 0 (Single IMG Configuration Only)
Slot No. Circuit Card Symbol Functions, Mounting Conditions
01 PA-PW55-A PWR This circuit card supplies operating power to circuit cards accommodated 
in the PIM.
03 PA-PW54-A DPWR This circuit card supplies operating power to circuit cards accommodated 
in the PIM.
13, 14 PH-SW 10 TSW...

Page 54

CHAPTER 2 NDA-24234
Pag e 24
Revision 3.0
INSTALLATION DESIGN
Figure 2-12   Controlling Circuit Cards in PIM
Table 2-6  Controlling Circuit Cards in PIM
Slot No. Circuit Card Symbol Functions, Mounting Conditions
01 PA-PW55-A PWR This circuit card supplies operating power to circuit cards accommodated 
in the PIM.
03 PA-PW54-A DPWR This circuit card supplies operating power to circuit cards accommodated 
in the PIM.
13, 14 PH-PC36 MUX This circuit card is an interface card for mounting line circuits...

Page 55

NDA-24234 CHAPTER 2
Page 25
Revision 3.0
INSTALLATION DESIGN
Figure 2-13   Controlling Circuit Cards in TSWM (Multiple IMG Configuration)
Table 2-7  Controlling Circuit Cards in TSWM (Multiple IMG Configuration)
Slot No. Circuit Card Symbol Functions, Mounting Conditions
00,  01 PH-PW14 PWRSW This circuit card supplies operating power to circuit cards accommodated 
in the TSWM.
08, 09 PH-PC20 DLKC This circuit card provides the Attendant Consoles (ATTs) with 
information such as ATT call...

Page 56

CHAPTER 2 NDA-24234
Pag e 26
Revision 3.0
INSTALLATION DESIGN
9.3 Preparation Of Trunking Diagram
Prepare the trunking diagram according to the customer’s specifications. Since there are different kinds of
switching offices such as a single office, network offices, etc. are involved, the trunking diagram must be pre-
pared per the customer’s specifications.
9.4 Preparation Of Module Group Face Layout And Port Accommodation Diagram
When mounting of various circuit cards in the PBX have been finalized, the...

Page 57

NDA-24234 CHAPTER 2
Page 27
Revision 3.0
INSTALLATION DESIGN
10.1 AC Input, DC Power, And Ground Cables
1. For AC input cable, VCT (Polyvinyl Chloride Cabtyre Cable) is to be used. However, if shielding is nec-
essary, as is the case when the AC input cable is to be installed in parallel with a low-voltage power cable,
etc., be sure to use VCT-S (Shielded Polyvinyl Chloride Cabtyre Cable).
2. For the power receiving terminals of the PBX, -48 V and G terminals are provided in dual (A side and B
side). For...

Page 58

CHAPTER 2 NDA-24234
Pag e 28
Revision 3.0
INSTALLATION DESIGN
Figure 2-15   DC Main Power Cable and Main Ground Cable (3- or 4-PIM System) (Single IMG Configuration)
BATTERY
AC  POWER
DISTRIBUTION
BOARD
VCT CABLE BATTERY
CABLES
RECTIFIER
POWER AND
GROUND CABLES
CV or IVPBX
(For 3/4 PIM Configuration)
Earth BarAC SERVICE
OUTLET-48V
AG
FE
MAT
MDF
GROUND
TERMINAL G
IV (G)
(ex. 6 AWG) FE E -48V
G IV (R)
IV (BL)-48V
G
B
A
B
Note 1:If the cover of CV Cable to be used is black, use the following clamp cover...

Page 59

NDA-24234 CHAPTER 2
Page 29
Revision 3.0
INSTALLATION DESIGN
Figure 2-16   DC Main Power Cable and Main Ground Cable (Multiple IMG Configuration)
BATTERY
AC POWER
DISTRIBUTION
BOARDVCT BATTERY
CABLES
RECTIFIER
POWER ANDGROUND CABLES
Earth BarAC SERVICE
OUTLETMAT
MDF
GROUND
TERMINAL
G
IV (G)
(ex. 6AWG) FEE -48V
G IV (R)
IV (BL)-48V
G
IV (G)IV (R)
IV (BL)
CABLES
(ex. 14AWG)
-48V
AGND
FE B
AB
-48V
AGND
FE B
AB
-48V
AGND
FE B
AB
DFB
CV or IV
CV or IV
CV or IV
CV or IV
iv(g)
IV (BL)
IV (R)
IMG 3
IMG 2
IMG 1...

Page 60

CHAPTER 2 NDA-24234
Pag e 30
Revision 3.0
INSTALLATION DESIGN
Table 2-8  Clamp Terminal Shape and Purpose
TYPE SHAPE PURPOSE REMARKS
AEnd terminal
TBranching or extension of power 