Page 51
NDA-24234 CHAPTER 2 Page 21 Revision 3.0 INSTALLATION DESIGN Figure 2-9 Face Layout of IMG2, 3 (Multiple IMG Configuration) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX) 00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21 00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21 00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21 00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413...
Page 52
CHAPTER 2 NDA-24234 Pag e 22 Revision 3.0 INSTALLATION DESIGN 9.2 Circuit Card Locations This section explains the main function of controlling circuit cards on a module basis. For more detailed infor- mation on each card, please refer to the NEAX2400 IMX Circuit Card Manual. Figure 2-10 Controlling Circuit Cards in LPM Table 2-4 Controlling Circuit Cards in LPM Slot No. Circuit Card Symbol Functions, Mounting Conditions 02, 03 PH-IO24 IOC (Input/ Output Controller)This circuit card supplies the...
Page 53
NDA-24234 CHAPTER 2 Page 23 Revision 3.0 INSTALLATION DESIGN Figure 2-11 Controlling Circuit Cards in PIM 0 (Single IMG Configuration Only) Table 2-5 Controlling Circuit Cards in PIM 0 (Single IMG Configuration Only) Slot No. Circuit Card Symbol Functions, Mounting Conditions 01 PA-PW55-A PWR This circuit card supplies operating power to circuit cards accommodated in the PIM. 03 PA-PW54-A DPWR This circuit card supplies operating power to circuit cards accommodated in the PIM. 13, 14 PH-SW 10 TSW...
Page 54
CHAPTER 2 NDA-24234 Pag e 24 Revision 3.0 INSTALLATION DESIGN Figure 2-12 Controlling Circuit Cards in PIM Table 2-6 Controlling Circuit Cards in PIM Slot No. Circuit Card Symbol Functions, Mounting Conditions 01 PA-PW55-A PWR This circuit card supplies operating power to circuit cards accommodated in the PIM. 03 PA-PW54-A DPWR This circuit card supplies operating power to circuit cards accommodated in the PIM. 13, 14 PH-PC36 MUX This circuit card is an interface card for mounting line circuits...
Page 55
NDA-24234 CHAPTER 2 Page 25 Revision 3.0 INSTALLATION DESIGN Figure 2-13 Controlling Circuit Cards in TSWM (Multiple IMG Configuration) Table 2-7 Controlling Circuit Cards in TSWM (Multiple IMG Configuration) Slot No. Circuit Card Symbol Functions, Mounting Conditions 00, 01 PH-PW14 PWRSW This circuit card supplies operating power to circuit cards accommodated in the TSWM. 08, 09 PH-PC20 DLKC This circuit card provides the Attendant Consoles (ATTs) with information such as ATT call...
Page 56
CHAPTER 2 NDA-24234 Pag e 26 Revision 3.0 INSTALLATION DESIGN 9.3 Preparation Of Trunking Diagram Prepare the trunking diagram according to the customer’s specifications. Since there are different kinds of switching offices such as a single office, network offices, etc. are involved, the trunking diagram must be pre- pared per the customer’s specifications. 9.4 Preparation Of Module Group Face Layout And Port Accommodation Diagram When mounting of various circuit cards in the PBX have been finalized, the...
Page 57
NDA-24234 CHAPTER 2 Page 27 Revision 3.0 INSTALLATION DESIGN 10.1 AC Input, DC Power, And Ground Cables 1. For AC input cable, VCT (Polyvinyl Chloride Cabtyre Cable) is to be used. However, if shielding is nec- essary, as is the case when the AC input cable is to be installed in parallel with a low-voltage power cable, etc., be sure to use VCT-S (Shielded Polyvinyl Chloride Cabtyre Cable). 2. For the power receiving terminals of the PBX, -48 V and G terminals are provided in dual (A side and B side). For...
Page 58
CHAPTER 2 NDA-24234 Pag e 28 Revision 3.0 INSTALLATION DESIGN Figure 2-15 DC Main Power Cable and Main Ground Cable (3- or 4-PIM System) (Single IMG Configuration) BATTERY AC POWER DISTRIBUTION BOARD VCT CABLE BATTERY CABLES RECTIFIER POWER AND GROUND CABLES CV or IVPBX (For 3/4 PIM Configuration) Earth BarAC SERVICE OUTLET-48V AG FE MAT MDF GROUND TERMINAL G IV (G) (ex. 6 AWG) FE E -48V G IV (R) IV (BL)-48V G B A B Note 1:If the cover of CV Cable to be used is black, use the following clamp cover...
Page 59
NDA-24234 CHAPTER 2 Page 29 Revision 3.0 INSTALLATION DESIGN Figure 2-16 DC Main Power Cable and Main Ground Cable (Multiple IMG Configuration) BATTERY AC POWER DISTRIBUTION BOARDVCT BATTERY CABLES RECTIFIER POWER ANDGROUND CABLES Earth BarAC SERVICE OUTLETMAT MDF GROUND TERMINAL G IV (G) (ex. 6AWG) FEE -48V G IV (R) IV (BL)-48V G IV (G)IV (R) IV (BL) CABLES (ex. 14AWG) -48V AGND FE B AB -48V AGND FE B AB -48V AGND FE B AB DFB CV or IV CV or IV CV or IV CV or IV iv(g) IV (BL) IV (R) IMG 3 IMG 2 IMG 1...
Page 60
CHAPTER 2 NDA-24234 Pag e 30 Revision 3.0 INSTALLATION DESIGN Table 2-8 Clamp Terminal Shape and Purpose TYPE SHAPE PURPOSE REMARKS AEnd terminal TBranching or extension of power cable