Note 1:
When the rectifier is in the equalize state (charging the batteries), the output DC voltage should be 1.5 to
2 volts higher than the float voltage. For example: the voltages for floating and equalizing are listed below:
Float:  50.5 V DC
Equalize:  52 V DC 
(Refer to
 Note 2.)
Note 2:The Equalize voltage is 1.5 to 2 V higher when an EMF panel (Diode Drop) is utilized. When an EMF panel
is not provided, the Float and Equalize Voltage...

Page 42

CHAPTER 2 NDA-24234
Pag e 12
Revision 3.0
INSTALLATION DESIGN
6.3 Power Distribution Box Requirements
1. The Power Distribution Box (PDB) should be installed with the following considerations:
2. The AC power source service outlet and the fuse for the junction box should be provided independently of
any equipment other than the switching equipment.
3. A warning notice should be attached to be PDB circuit breaker so that it will not be turned off accidentally.
4. The Power Distribution Box should be...

Page 43

NDA-24234 CHAPTER 2
Page 13
Revision 3.0
INSTALLATION DESIGN
8. INSTALLATION TOOLS
Table 2-2 shows the tools used in a typical NEAX2400 IMX installation.
Table 2-2  Typical Installation Tools
FUNCTION TOOLS PURPOSE
MarkingSteel Tape Measure
L-Square
Iron Square 
Iron LevelCenter Punch 
Step Ladder 
ScriberFor Leveling and 
Marking Plumb 
Line
DrillingElectric Drill 
Electric Vibration Drill 
Hammer 
Point Drill 
Drill Bit for ConcreteConcrete Chisel 
Drill Bit for Metal 
Power Cable Drum...

Page 44

CHAPTER 2 NDA-24234
Pag e 14
Revision 3.0
INSTALLATION DESIGN
9. SYSTEM ACCOMMODATION
9.1 System Accommodation
Module Group Configuration and Conditions for Configuration
The module group configuration of the PBX is shown in Figure 2-3, and the conditions for configuration are
shown in Table 2-3.
Figure 2-3   System Configuration
TO P U
PIM2 PIM3
PIM1
PIM0
TSWMFA N UIMG1
BASEU
max. 1536 ports 
max. 1152 portsmax. 768 portsmax. 384 ports
(2048 time slots)
(1536 time slots)(1024 time slots)(512 time...

Page 45

NDA-24234 CHAPTER 2
Page 15
Revision 3.0
INSTALLATION DESIGN
Note:
A NFILU is mounted in BASEU.
Table 2-3  Conditions for Configuration
UNIT NAME NUMBER OF MODULES CONDITIONS REMARKS
FANU
 (Fan Unit)PIM 
Less than two modulesMounted in TOPU
PIM 
Three or more modulesMounted in between the 2nd PIM and 
the 3rd PIM
2nd NFILU 
(Noise Filter)Less than two modules Not required
Three or more modules Mounted in BASEU
TOPU
 (Top Unit)Equipped with PZ-DK222 (KEY) and 
PZ-DK223 (DSP) Cards 

Page 46

CHAPTER 2 NDA-24234
Pag e 16
Revision 3.0
INSTALLATION DESIGN
Figure 2-4   Time Slot, Group Number Assignment
Note 1:Extended Group No. can be used by FCH (PA-FCHA) card. For more detailed information, see
the “Fusion Network System Manual.”
Note 2:A PIM consists of 384 physical ports (512 total ports).
00 02 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
PIM
192 TS
16
32 TS/Physical ports
161616
1616
161616
32
32
16 32
1616 16
1616
16 16 16 3232 192 TS Slot No.
Number
of
Time Slots
(16)...

Page 47

NDA-24234 CHAPTER 2
Page 17
Revision 3.0
INSTALLATION DESIGN
Figure 2-5   Face Layout (Single IMG Configuration)
PH-SW10 (TSW0) PH-SW10 (TSW1)
PH-PC36 (MUX0) PH-PC36 (MUX1)
PH-PC36 (MUX0) PH-PC36 (MUX0)PH-PC36 (MUX1) PH-PC36 (MUX1)
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
0005 01 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21...

Page 48

CHAPTER 2 NDA-24234
Pag e 18
Revision 3.0
INSTALLATION DESIGN
Figure 2-6   Face Layout of IMG0 (Multiple IMG Configuration)
P H -P C 3 6 (M U X 0 )P H -P C 3 6 (M U X 1)
PH-PC36 (M UX0) PH-PC36 (MUX1)
PH-PC36 (M UX0)
PH-PC36 (MUX0) PH-PC36 (MUX1)
PH-PC36 (M UX1)
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20...

Page 49

NDA-24234 CHAPTER 2
Page 19
Revision 3.0
INSTALLATION DESIGN
Figure 2-7   Location of Terminating Resistors on the TSWM Back Plane (Multiple IMG Configuration)
PWRB
MISC1B
MISC2B
MISC3B
MIO31
MUX003
MUX002MUX001
MUX000
MUX013MUX012 MUX011
MUX010MUX023
MUX022MUX021 MUX020MUX033
MUX032
MUX031 MUX030MUX103
MUX102MUX101
MUX100MUX113MUX112 MUX111 MUX110MUX123
MUX122MUX121MUX120MUX133
MUX132 MUX131MUX130
EMAFH
EXCLK0EXCLK1IOP0
IOP1MIO30
MIO20
MIO0
MIO21
MIO1 MISC3AMISC2A
MISC4B
MISC5BMISC5A MISC4AMISC1A
PWRA...

Page 50

CHAPTER 2 NDA-24234
Pag e 20
Revision 3.0
INSTALLATION DESIGN
Figure 2-8   Face Layout of IMG1 Front View (Multiple IMG Configuration)
PA-PW54-A (PWR1)PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX) PH-PC36 (MUX) PH-PC36 (MUX)
PH-PC36 (MUX)
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15 20 2319 22 18 17 16 11 1413 12 21
00 0501 02 03 04 06 07 08 09 10 15...
Start reading NEC Neax 2400 Imx Installation Manual

Related Manuals for NEC Neax 2400 Imx Installation Manual

All NEC manuals