NDA-24234 CHAPTER 5 Page 351 Revision 3.0 INSTALLATION TEST PROCEDURE NAP-200-047 Sheet 1/2 Test of Connection and Alternate Routing to All Tie Lines START Test the trunks in the primary route one at a time.Make busy all trunks in the primary route except the trunk to be tested. Station “A” calls Station “B” via the primary route. After Station “B” answers, check the normality of the speech condition including the speech level, presence of noise, and one-way speech. Release. Make all the trunks in...
Page 382
CHAPTER 5 NDA-24234 Pag e 35 2 Revision 3.0 INSTALLATION TEST PROCEDURE Figure 047-1 Combination of Tie Line Network and Public Network Figure 047-2 Tie Line Network NAP-200-047 Sheet 2/2 Test of Connection and Alternate Routing to All Tie Lines Basic Route Station AStation B PBX to be tested Tie Line Network Public NetworkPBX TRKs TRKs Alternate Route PBX PBX PBX Station AStation B TRKs TRKs ALTERNATE ROUTE BASIC ROUTEPBX to be tested
Page 383
NDA-24234 CHAPTER 5 Page 353 Revision 3.0 INSTALLATION TEST PROCEDURE Figure 048-1 Test of Tandem Connection to Tie Line NAP-200-048 Sheet 1/2 Test of Tandem Connection to Tie Line START Test of direct dial-in tandem connectionTest of Primary Route Station “A” calls Station “B”. Confirm speech between Stations “A” and “B”. Release. Test of Alternate Route Make busy all the trunks in the primary route. Station “A” calls Station “B”. Confirm speech between Stations “A” and “B”. Release. Un-busy (make...
Page 384
CHAPTER 5 NDA-24234 Pag e 35 4 Revision 3.0 INSTALLATION TEST PROCEDURE NAP-200-048 Sheet 2/2 Test of Tandem Connection to Tie Line Test of tandem connection via ATTCONStation “A” dials the access code for the ATTCON. The ATTCON answers and sets up a tandem connection to Station “B”. The ATTCON releases, and speech between Stations “A” and “B” is confirmed. Release. Test of tandem connection via stationStation “A” calls Station “C”. Station “C”, after answering, makes a Switch Hook Flash (SHF) and...
Page 385
NDA-24234 CHAPTER 5 Page 355 Revision 3.0 INSTALLATION TEST PROCEDURE For the PBX, PADs can be set according to the connecting status of the Tie Line involved. (a) For an outgoing/incoming call via a Tie Line: Via MAT command “ARTD” and switch settings on the TLT circuit card. (b) For a tandem Tie Line connection: Via command “APAD” or switch settings on the TLT circuit card(s). At both the originating and terminating offices, an 8 dB PAD is set for the EMT route via the “ARTD” command or switch...
Page 386
CHAPTER 5 NDA-24234 Pag e 35 6 Revision 3.0 INSTALLATION TEST PROCEDURE When setting up a No. 7 CCIS Network, PAD setting differs from that in the analog network. (c) For an outgoing call to/incoming call from a Tie Line: Vi a “ARTD” command. (d) For a tandem Tie Line connection: Vi a “APAD” command. At both the originating and terminating offices, 0 dB is set to the outgoing side and 8 dB is set to the terminating of the DTI/CCT route via “ARTD” command. At the tandem office, 0 dB is set for both...
Page 387
NDA-24234 CHAPTER 6 Page 357 Revision 3.0 CHAPTER 6 FAULT RECOVERY DURING TESTS 1. GENERAL The fault recovery procedures described in this Chapter are used when a connection cannot be established in the normal manner or an abnormal connection is discovered as a result of the tests designated in Chapter 4, ”SYS- TEM STARTUP”, and Section 2., “BASIC CONNECTION TEST” of CHAPTER 5. 2. OUTLINE OF PROCEDURE FOR FAULT RECOVERY The procedures for performing fault recovery are described in the NAPs indicated to...
Page 388
CHAPTER 6 NDA-24234 Pag e 35 8 Revision 3.0 FAULT RECOVERY DURING TESTS NAP-200-050 Sheet 1/2 Abnormal Lamp Indications After System Startup START Check conducted when the OPE lamp (Green) does not turn ON on any circuit cards mounted in a PIM Using MAT command “AU N T”, check whether UNIT data has been assigned. Replace the TSW/MUX card in the PIM with a spare. Check whether the flat cable connected to the “BUSXX” terminal on the PIM backplane is securely connected. A PIM will occasionally malfunction...
Page 389
NDA-24234 CHAPTER 6 Page 359 Revision 3.0 FAULT RECOVERY DURING TESTS NAP-200-050 Sheet 2/2 Abnormal Lamp Indications After System Startup Check conducted when the OPE lamp (Green) does not turn ON on a Trunk circuit card. Confirm that the MB switch of the circuit card is DOWN. Using command “AT R K”, check whether Trunk data has been assigned for the circuits on the card. Replace the circuit card with a spare. Check conducted when the OPE lamp of a Trunk circuit card turns ON, but the BL lamp (Red)...
Page 390
CHAPTER 6 NDA-24234 Pag e 36 0 Revision 3.0 FAULT RECOVERY DURING TESTS NAP-200-051 Sheet 1/1 DT (Dial Tone) Connection Fault START Dial tone is not heard. On the MDF, check the cross connections between the telephone and the corresponding line circuit. Check whether the LT cable is securely connected to the PIM. Replace the LC card with a spare. DT cannot be heard from one or more lines of the same circuit card. Replace the LC card with a spare. DT cannot be heard from the lines accommodated by a...