Page 291
NDA-24234 CHAPTER 3 Page 261 Revision 3.0 INSTALLATION PROCEDURE 12. SELECTION OF CONFIGURATION ITEM Using a numeric key, press the desired number in Configuration Menu. A menu for assigning configuration data appears. Assign configuration data referring to “Assignment of Configuration Data” on the next page. Figure 016-21 Selecting a Configuration Item NAP-200-016 Sheet 31/41 Installation of the DESK CONSOLE and Cable Connection Alarm LDN TIE Busy ATND NANS Recall EMG BV TRKSL Call Park SC SVCPAGE...
Page 292
CHAPTER 3 NDA-24234 Pag e 26 2 Revision 3.0 INSTALLATION PROCEDURE 13. ASSIGNMENT OF CONFIGURATION DATA This section explains how to assign each configuration data. When assigning configuration data, the following shad- ed keys are used. Figure 016-22 Assigning Configuration Data NAP-200-016 Sheet 32/41 Installation of the DESK CONSOLE and Cable Connection Alarm LDN TIE Busy ATND NANS Recall EMG BV TRKSL Call Park SC SVCPAGE StartREC [SRC key] Night Position BusyMute DEST SRC 3 DEF2 ABC 1 L 6 L 5 L 4...
Page 293
NDA-24234 CHAPTER 3 Page 263 Revision 3.0 INSTALLATION PROCEDURE 14. HEADSET/HANDSET This item specifies an optional device connected to the HAND H/S0 connector. Note:With regard to the H/S1 connector, only the Headset is connected. Accordingly, data assignment for H/S1 connector is not required. (d) Press the desired number. An asterisk shows the selected number. 1. Headset is connected to the HAND H/S0 connector 2. Handset is connected to the HAND H/S0 connector SRC: Return to Configuration Menu...
Page 294
CHAPTER 3 NDA-24234 Pag e 26 4 Revision 3.0 INSTALLATION PROCEDURE 15. HEADSET TYPE This item specifies the type of Headset connected to the H/S1 connector. (d) Press the desired number. An asterisk shows the selected number. 1. The type of Headset is “SUPRA” 2. The type of Headset is “COROLLE” SRC: Return to Configuration Menu Note:Default setting is “1: SUPRA”. (b) Press the SRC key. The display returns to Configuration Menu. (c) When configuration data assignment is finished, proceed to UPDATING...
Page 295
NDA-24234 CHAPTER 3 Page 265 Revision 3.0 INSTALLATION PROCEDURE 16. MUTE This item specifies On/Off setting of the mute function for the HAND H/S0 or H/S1 connector. While the mute function is set to On, if the Mute key is pressed, the voice at the DESK CONSOLE side is not sent to the other party. (a) Press the desired number. An asterisk shows the selected number. 1. Both H/S0 and H/S1 are set to On 2. Only H/S0 is set to On 3. Only H/S1 is set to Off SRC: Return to Configuration Menu Note:Default...
Page 296
CHAPTER 3 NDA-24234 Pag e 26 6 Revision 3.0 INSTALLATION PROCEDURE 17. REC CONTROL This item specifies the operation mode of a recording device. The following two types of modes are available: Manual mode Manual mode is available when the REC circuit card is mounted in the system. When the REC key is pressed, the system starts recording and the REC lamp lights. When the REC key is pressed again, the re- cording stops and the REC lamp goes off. Automatic mode In Automatic mode, a dedicated recording...
Page 297
NDA-24234 CHAPTER 3 Page 267 Revision 3.0 INSTALLATION PROCEDURE 18. SUP CONNECTION This item specifies whether the supervisory console is connected or not. (a) Press the desired number. An asterisk shows the selected number. 1. Supervisory Console is connected 2. Supervisory Console is not connected SRC: Return to Configuration Menu Note:Default setting is “1: NONE”. (b) Press the SRC key. The display returns to Configuration Menu. Note:Do not change this data. (c) When configuration data assignment is...
Page 298
CHAPTER 3 NDA-24234 Pag e 26 8 Revision 3.0 INSTALLATION PROCEDURE 19. REC VOLUME ADJUSTMENT This item specifies the recording level of the received voice from the other party. Note that the voice level at the operator side cannot be adjusted. (a) Press the desired number. An asterisk shows the selected number. 1. +2dB Up 2. 0dB (Standard level) 3. -4dB Down 4. -8dB Down SRC: Return to Configuration Menu Note:Default setting is “2: 0dB”. (b) Press the SRC key. The display returns to Configuration Menu....
Page 299
NDA-24234 CHAPTER 3 Page 269 Revision 3.0 INSTALLATION PROCEDURE 20. BLF This item specifies On/Off setting of the BLF function. When using BLF function, system data assignment is also required. (a) Press the desired number. An asterisk shows the selected number. 1. BLF Available 2. BLF Not available SRC: Return to Configuration Menu Note:Default setting is “2: DISABLE”. (b) Press the SRC key. The display returns to Configuration Menu. (c) When configuration data assignment is finished, proceed to...
Page 300
CHAPTER 3 NDA-24234 Pag e 27 0 Revision 3.0 INSTALLATION PROCEDURE 21. HOLD/START/RELEASE/SWAP This item specifies the locations of HOLD, START and RELEASE key. (a) Press the desired number. An asterisk shows the selected number. 1. Original setting 2. Swapped setting Note:The locations of each key changes as shown below. SRC: Return to Configuration Menu Note:Default setting is “1: ORIGINAL”. (b) Press the SRC key. The display returns to Configuration Menu. (c) When configuration data assignment is...