NEAX2000 IVS2 CCIS System ManualPage 308 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST LOOP-BACK TEST Table 5-2 Alarm Indications on the 30DTI Card (Loop-Back Test) LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RU N F la s h (120 IPM)On or Off Abnormal operation of DTI cardConfirm the programming data: CM05, CM07 YY=01. Check to see if the SENS switch is set as per the AP number (04-15, 20-31) assigned by CM05. Reset the MB switch (Down→Up→Down) If the fault cannot be cleared, replace...
Page 322
CHAPTER 5 OPERATION TEST LOOP-BACK TEST NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 309 STEP 4: With respect to channels assigned as trunks, perform call origination and call termination tests. Prior to the performance test, make busy all trunks other than the test trunk by means of CME5. Dial the trunk route access code and a station number. In the case of a loop-back test, the same BL lamp lights up on the calling-side DTI card and the called-side DTI card. Talk with the called...
Page 323
NEAX2000 IVS2 CCIS System ManualPage 310 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test INTEROFFICE TRANSMISSION LINE TEST To confirm inter-office synchronization and speech quality using “In-Service” transmission lines, do the following steps. STEP 1: Connect the transmission line to the MDF or CONN card. STEP 2: Make busy the channels except the channel tested by CME5. STEP 3: Confirm indication lamps on the DTI card, as per the following table. Alarm...
Page 324
CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 311 Table 5-3 Alarm Indications on 24DTI (Interoffice Transmission Line Test) LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RU N F la s h (120 IPM)On or Off Abnormal operation of DTI cardConfirm the programming data: CM05, CM07 YY=01. Check to see if the SENS switch is set as per the AP number (04-15, 20-31) assigned by CM05. Reset the MB switch (Down→Up→Down) If...
Page 325
NEAX2000 IVS2 CCIS System ManualPage 312 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST Interoffice Transmission Line Test Table 5-4 Alarm Indications on 30DTI (Interoffice Transmission Line Test) LEDLED INDICATION FAULT NORMAL FAULT CAUSE ACTION RU N F la s h (120 IPM)On or Off Abnormal operation of DTI cardConfirm the programming data: CM05, CM07 YY=01. Check to see if the SENS switch is set as per the AP number (04-15, 20-31) assigned by CM05. Reset the MB switch (Down→Up→Down) If the...
Page 326
CHAPTER 5 OPERATION TEST PLO Operation Test NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 313 PLO OPERATION TEST To confirm the PLO operation do the following tests. Clock Signal Generation Test Clock Signal Synchronization Test To be tested when the PBX is a clock receiver office. Interoffice Synchronization Test Source Office Mode Test To be tested when the PBX is a clock source office. Clock Signal Generation Test This test checks to see if the PLO keeps generating clock...
Page 327
NEAX2000 IVS2 CCIS System ManualPage 314 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST PLO Operation Test Clock Signal Synchronization Test This test checks to see if the PLO keeps synchronizing with the external clock signals, when the external clock signals from network has input again after it has stopped once. Do the following steps using “In Service” transmission lines. (1) When providing one clock supply route STEP 1: On the DTI0 card extracting clock signals, set the SW-1 and SW-2 to OFF to...
Page 328
CHAPTER 5 OPERATION TEST PLO Operation Test NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 315 (2) When providing two clock supply routes STEP 1: On the DTI cards extracting clock signals, set the switches as follows to change the clock supply route from 0 to 1. 30DTI0 card: SW-1 to OFF, SW-2 to OFF 30DTI1 card: SW-1 to OFF, SW-2 to ON 24DTI0 card: SW0-1 to OFF, SW0-2 to OFF 24DTI1 card: SW0-1 to OFF, SW0-2 to ON STEP 2: Originate an outgoing call via trunks. STEP 3: After an...
Page 329
NEAX2000 IVS2 CCIS System ManualPage 316 ND-70918 (E), Issue 1.0 CHAPTER 5 OPERATION TEST PLO Operation Test STEP 9: Repeat the procedure shown in STEP 2 and STEP 3. NOTE:If noise periodically occurs, replace the MP card after checking the switch settings on the MP card, and do the above test again. Interoffice Synchronization Test This test checks to see if noise occurs while calling with the opposite office, by difference of the clock signal frequency between the offices. Do the following steps...
Page 330
CHAPTER 5 OPERATION TEST PLO Operation Test NEAX2000 IVS2 CCIS System Manual ND-70918 (E), Issue 1.0 Page 317 STEP 3: Confirm indication lamps on the MP card. NOTE:When the CLK lamp lights on the MP card, the clock signal is not generated from the MP card. Check the switch settings on the DTI and MP card. For details of the lamp indications, refer to CHAPTER 4 on Page 259. STEP 4: Originate an outgoing call via trunks. STEP 5: After an outgoing connection via trunk has been established, confirm...