NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 31 Calling Name Display - CCIS General Description This feature permits the station name of a calling or called party at another switching office via the CCIS net- work to be displayed either on a Multiline Terminal or an Attendant Console. Operating Procedure No manual operation is required. Service Conditions 1. The calling/called station name (maximum of eight characters) is displayed on the lower line of the LCD of a Multiline Terminal or an Attendant Console. 2. The called station name will be displayed on the calling Multiline Terminal or Attendant Console during ringing period and for six seconds after the called party answers the call. 3. The calling station name will be displayed when the Multiline Terminal is ringing on its Prime Line or the Attendant Console and for six seconds after the called party answers the call. 4. If the called party is forwarded via Call Forwarding - Outside, the called name display at the calling Multiline Terminal or Attendant Console will be the name of the station which answers the call. 5. If the network includes the office which Calling Name Display is restricted, or is connected via no CCIS line, this feature may not be allowed. 6. If the network includes 2400 RDS, MDS, HDS, they must have L version software for Name Display to work. 7. Index 241 bit 1 in the 2400 must be set for 16 digits to display the 2000 IVS Name. 8. If 56K CCIS is used, ESF (24 multiframe) must also be used.

NEAX2000 IVS CCIS Features and Specifications Page 32Addendum-002 NDA-24159, Revision 2.2 November, 1997 Calling Number Display - CCIS General Description This feature permits the number of a calling or called party, at another switching office, to be displayed either on a Multiline Terminal or an Attendant Console. Operating Procedure No manual operation is required. Service Conditions 1. The called party’s number (maximum of sixteen digits) will be displayed on the Multiline Terminal when the called party answers the call. 2. The calling party’s number will be displayed when the Multiline Terminal is ringing on its Prime Line. 3. If the called party is forwarded via Call Forwarding - All Calls, Call Forwarding - Busy Line, etc., the called number display at the calling Multiline Terminal will be the number of the station which answers the call. 4. When a call with calling party number information (ISDN CPN/Caller-ID/T1-ANI) is received over CCIS, the information can be transferred transparently, a maximum of 16 digits can be displayed on the LCD of the Multiline Terminal, and it also can be sent to the SMDR, or MCI with ANI if provided. Below shows the conditions whether the calling party number is displayed or not when the call is transferred or forwarded to another station. • When the call is transferred or forwarded to the station in the same office, the LCD of the transferred/ forwarded station displays the calling party number. • When the call is transferred to the station of another office over CCIS, the LCD, SMDR, MCI, or ANI of the transferred station does not display the calling party number. • When the call is forwarded to the station of another office over CCIS, the LCD of the forwarded station displays the calling party number. 5. Examples of number displays for inter-office connections are shown in the attached diagrams for the follow- ing cases: • Multiline Terminal to Multiline Terminal • Multiline Terminal to Attendant Console • Multiline Terminal to trunk •Attendant Console to Multiline Terminal • Trunk to Multiline Terminal • Intermediate station number display (1) • Intermediate station number display (2)

NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 33 Calling Number Display - CCIS NEAX2000/2400 Elapsed time Called station CALLED CALLINGCCIS820822 NEAX2000 IVSB: 4211 A: 2000 A: Dial 8224211 Calling party (A)Called party (B) Called station NEAX2000 IVS (Time Display) (Time Display)CCIS LinkCCIS Link 821 (Time Display)8202000 numberCalling station number flashes office code + station number (Max. 8 digits) PARTY ANSWERS8224211 8224211 8202000 (Time Display) Elapsed time Calling station numbernumber Multiline Terminal to Multiline Terminal

NEAX2000 IVS CCIS Features and Specifications Page 34NDA-24159, Issue 2 Calling Number Display - CCIS NEAX2000/2400 Elapsed time Called party CALLED CALLINGCCIS820822 NEAX2000 IVSB: ATT A: 2000 A: Dial 0 Calling party (A)Called party (B) Called station NEAX2000 IVS 821 number PARTY ANSWERS0 822 Trunk number Multiline Terminal to Attendant Console TIE lamp lights Office codeTrunk Group Number TIE lamp lights OPR 112 3 4

NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 35 Calling Number Display - CCIS NEAX2000/2400 Called party CALLED CALLINGCCIS820822 NEAX2000 IVS A: 2000 A: Dial Calling party (A)NEAX2000 IVS 821 Dialed number PARTY ANSWERS Multiline Terminal to Tie Trunk Line Type of trunk TIE TIE 824-4211 (Time Display) (Time Display)8244211 . . .

NEAX2000 IVS CCIS Features and Specifications Page 36NDA-24159, Issue 2 Calling Number Display - CCIS 112 3 4 820OPR 820OPR 224 21 NEAX2000/2400 Elapsed time Calling party CALLED CALLINGCCIS820822 NEAX2000 IVSB: 4211 A: ATT Calling party (A)Called party (B) Called station NEAX2000 IVS 821 number PARTY ANSWERS Attendant Console (HA610Z) to Multiline Terminal Office code Trunk Group Number Office code (Time Display) (Time Display) Calling party number flashes Trunk number1RT= 10 TK = 1234

NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 37 Calling Number Display - CCIS . . . . . . CCSA OPR NEAX2000/2400 Elapsed time Calling party CALLED CALLINGCCIS820822 NEAX2000 IVSB: 4211 Called party (B)NEAX2000 IVS 821 PARTY ANSWERS Central Office to Multiline Terminal Type of trunk Type of trunk (Time Display) (Time Display) Calling party number flashes RT= 10 TRK = 123 822-4211

NEAX2000 IVS CCIS Features and Specifications Page 38NDA-24159, Issue 2 Calling Number Display - CCIS 8202000 NEAX2000/2400 Elapsed time Calling station CALLED CALLINGCCIS820822 NEAX2000 IVSB: 4211 Called party (C)NEAX2000 IVS 821 PARTY ANSWERS Intermediate Station Number Display (1) Type of trunk (Time Display) Calling party number flashes A: 2000 A: Dial 822-4211 C: 5000 B: Intermediate station B C Call forwarding all calls 8224211 Calling party (A) (Time Display) Dialed number Type of forwarding Intermediate station number (B) 8225000 (Time Display) 8202000 (Time Display) numberElapsed time Called station number

NEAX2000 IVS CCIS Features and Specifications NDA-24159, Issue 2 Page 39 Calling Number Display - CCIS 8202000 NEAX2000/2400 Elapsed time Calling station CALLED CALLINGCCIS820822 B: 4211 Called party (C) 821 PARTY ANSWERS Intermediate Station Number Display (2) (Time Display) Calling party number flashes A: 2000 A: Dial 822-4211 C: 5000 B: Intermediate station B C Call forwarding all calls 4211 Calling party (A) (Time Display) Dialed number 8225000 (Time Display) 8202000 (Time Display) numberElapsed time Called station number

NEAX2000 IVS CCIS Features and Specifications Page 40Addendum-001 NDA-24159, Revision 2.1 April, 1997 Centralized Billing - CCIS General Description This feature is used to collect billing information from each office within the network and to direct it to the associated center office. Billing information is then forwarded to the central billing centers via RS-232C interfaces. Operating Procedure No manual operation is required. The call record outputs are produced automatically. Service Conditions 1. An IVS is generally used as a local office. However if all the PBXs within the network are IVS, an IVS can be a center office for centralized billing. 2. The information storage capacity of the local office is approximately 1,000 calls. 3. If billing information in excess of the above mentioned storage capacity is required for a local office, then the addition of a PN-ME00 card with SRAM card allows 12,000 records of storage per system. 4. When an IVS is the center office, the billing information is sent to a SMDR system with NEAX2400 IMS format. 5. When an IVS is the center office, a maximum number of call records which can be sent to the SMDR system is about 4000 per hour at 4800 bps on the RS-232C port. When the AP of the center office can not send the call records to the SMDR, due to such as a failure of the SMDR system, call records are stored in the memory buffer on the AP (about 500 call records). Moreover, if the memory buffer is filled, the call records are stored in an AP of a local office. 6. When a NEAX2400 is the center office, either the Sub Line or the My Line number can be selected by system programming to be sent to the SMDR terminal. 7. When an IVS is the center office, only the My Line number can be sent to the SMDR terminal.