NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 34NDA-24158, Issue 2
Attendant Console (SN610 ATTCON)
Dialed Number Identification Service (DNIS)
programming. When an incoming call to any of these trunks is received, an Attendant Call Selection key will
flash and the LCD display will indicate the Listed Directory Number associated with that trunk route.
Operating Procedure
Refer to Attendant Call Selection Features and Specifications.
Service Conditions
1. A maximum of one Listed...

Page 62

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 35
Attendant Console (SN610 ATTCON)
Incoming Call Identification
7. The company name can be displayed when the Attendant has answered the Listed Directory Number call or
Tie Line call forwarded from the station. If the name display feature is assigned for that station, the station
name is displayed (the station name display has priority over the company name display).
8. If using ANI or ISDN, some of the characters of...

Page 63

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 36NDA-24158, Issue 2
Attendant Console (SN610 ATTCON)
Multi-function Key
Multi-function Key
General Description
This feature allows the top row of keys on the Attendant Console to perform and display multiple functions in
accordance with the status of call processing.
Operating Procedure
No manual operation is required.
Service Conditions
1. Multi-Function Keys can be assigned to key numbers 01-06 located directly below the LCD.
2. The...

Page 64

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 37
Attendant Console (SN610 ATTCON)
Pushbutton Calling – Attendant Only
6. The NEAX2000 IVS operates only on a switched-loop basis. Fixed-loop operation is not available.
7. To place a multiple console system (or a multiple console tenant group) into Night Service, a prepro-
grammed master console must press the MODE, NITE and ANS key. If one of the other consoles enters
Night Service, all calls addressed to that console...

Page 65

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 38NDA-24158, Issue 2
Attendant Console (SN610 ATTCON)
Time Display
4. Serial Calling is allowed when a station is involved in an Attendant Conference.
5. No features are denied toward a line or trunk involved in a Serial Call.
Time Display
General Description
This feature provides a digital time display on the Attendant Console (SN610) LCD.
Operating Procedure
Time is constantly displayed on the Attendant Console LCD.
Service Conditions...

Page 66

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 39
Attendant Console (SN610 ATTCON)
Unsupervised Trunk-to-trunk Transfer By Attendant
Operating Procedure
1. An incoming call is received and answered in the normal manner. The trunk number is displayed.
2. The Attendant dials the access code of the outgoing route, then the destination number. The dialed digits are
displayed.
3. If the feature is allowed, the display will change to show the selected outgoing trunk...

Page 67

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 40NDA-24158, Issue 2
Attendant Delay Announcement
Attendant Delay Announcement
General Description
This feature provides an announcement, via a Digital Announcement Trunk Card, to external calls that are not
answered by the attendant within a predetermined time.
Station Application
Not applicable.
Operating Procedure
No manual operation required.
Service Conditions
1. Up to eight calls can be connected to one circuit of a Digital...

Page 68

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 41
Attendant Lockout
Attendant Lockout
General Description
This feature denies an Attendant the ability to re-enter an established trunk or station connection without being
recalled by that station after the call is put in consultation hold.
Station Application
Attendant Consoles.
Operating Procedure
No manual operation is required.
Service Conditions
1. This feature is mutually exclusive with the Attendant Override...

Page 69

NEAX2000 IVS Business/Hotel/Data Features and Specifications
Page 42NDA-24158, Issue 2
Attendant Overflow
Attendant Overflow 
General Description
When an incoming call, which has terminated from a trunk to the Attendant Console, remains unanswered after
a predetermined time period, this feature provides a change to Night Service for that particular trunk.
Station Application
Attendant Consoles.
Operating Procedure
No manual operation is required.
Service Conditions
1. The Night Service assignment applied...

Page 70

NEAX2000 IVS Business/Hotel/Data Features and Specifications
NDA-24158, Issue 2
Page 43
Attendant Override
Attendant Override
General Description
This feature permits an Attendant to enter a busy connection (station or trunk) using the Attendant Console.
When this feature is activated, a warning tone is sent to the connected parties after which, they are connected
with the Attendant in a three-way bridge.
Station Application
Attendant Consoles.
Operating Procedure
To activate Attendant Override
1....