NEC Electra 616 General Installation Manual
Here you can view all the pages of manual NEC Electra 616 General Installation Manual. The NEC manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 21
_..._,.^ ..___ ___ _.....__..... -- .-.._ . -. ..__. -.. ..- -L,.-L- TO KSU r CABLE MODULAR TERMINAL ________--__ J Fig. 250-2 View of Modular Terminal for Connection of ET-$-l Telephone Page 200-10 ?
Page 22
” & 2502 EB-6-l installation The EB-6 -1 is a modular electronic busy lamp field. Each unit is provided with a 9V DC 03A power supply for LED illumination. The power supply is to be plugged into a standard 117V AC outlet. Each BLF requires 1 -pair cabling to the main distribution frame (MDF). The maximum cable length is 700 ft. using standard 24 AWG cable and 1,150 ft. using standard 22 AWG cable. Refer to Section 140, “Cabling Requirements”, of this manual. For BLF connection, see Figures...
Page 23
____..__ _._- - . . . . . ..- ._.--. _- .-_ ..I ._._ _-__-l-._-~-.C_~“~-~~ ‘xL..?Au.-.. . . . . __.~, TO KSU BLFCABLE I I MODULAR I TERMINAL I L _____------- -I Fig. 2504 View of Modular Terminal for Connection of EB-6-1 BLF / EB-6-1 BLF TO POWER SUPPLY Fig. 250-5 Power Supply Connection Page 200-12
Page 24
250.3 DP-6-1 Installation The DP-6-1 is a Door/Monitor phone unit. Each door phone requires 1 pair cabling to the Main Distribution Frame (MDF). The maximum cable length is 700 ft. using standard 24 AWG cable and 1,150 ft. using standard 22 AWG cable. Refer to Section 140, “Cabling Requirements” of this manual. To prepare the door phone for wall mounting losen the set screw and remove the door phone unit from the mounting plate. Use the two screws provided or other appropriate fastners to fiiy...
Page 25
260 260.1 installing Options Music On Hold Provision has been made to allow connection of a locally provided external music source to provide Music- On-Hold for held CO/PBX calls. Connection of the Music Source is made at the Jl Block of the Main Distribution Frame (MDF). The output signal level should be approxi- mately 1 milliwatt with 8 ohms impedance. See Figure 260.3 and Table 240.3 for connection information to MDF . 260.2 External Paging Speaker When a PBS-S KTU is installed in the ES...
Page 26
26043 Security Control Equipment Provision has been made to allow connection of a locally-provided security control system. For this purpose the PBS-S KTU contains 2 individual control circuits that, when activiated, provide an audible alarm through all idle keyset speakers and a visual alarm on each keyset display. Each security circuit can be activiated by means of an external make (closed) or break (open) contact. The SW1 switch on the PBS-S KTU is used to set the desired break or make...
Page 27
_. _. __. -.- . . CLK-S Y L-BR 1SE BR-Y L 1SEG YLSL MOH SL-YL MOHG VI-BL SKR BL-VI SKRG VI-OR BGM OR-VI BGMG VI-SL 2PFT 44 -oo-oo- -o&a- --Qc2Lo- -o&o- -o&o- -4&o- -oEoo- -ocPoo- -oEoo- -o&* -o&c -o&* 25 -ac--Oo- : SECURITY 1 ACTIVATION CONTACT ---p&&i EXTERNAL PAGING SPEAKERS (600.52) Jl BLOCK OF MDF (668-50 OR 66M-50) Fig. 260-3 Connection of Optional Features POWER FAILURE CONNECTION FOR CO/PBX 1 POWER FAILURE CONNECTION FOR COIPBX 2 ..- Page 200-16
Page 28
I YL-BR 2SE 00% BR-YL 2SEG 00% YL-SL EA 00% SL-YL EAG O& PBS-S AGING AMPLIFIER - VI-BL EAB oa RELAY CONTACT SHOWN BL-VI EAS 00% (NON-OPERATED) IS OPERATED FOR THE DURATION OF AN t VI -OR EAM Oc% EXTERNAL PAGE OR-VI 00% h J2 BLOCK OF MDF (668-50 OR 66M-50) Fig. 2604 Connection of Optional Features t Page 200-17 _-
Page 29
SECTiON 300 CONTENTS 310 Explanation of Programming . . . . . . . . . . . . . . . . . . . . . . . . 300-l 320 Programming Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . 300-3 320.1 Going Off-Line from Keyset 1 320.2 Selecting a Memory Block 320.3 Selecting Addresses Using the Dial Pad 320.4 Entering Data 320.5 Use of Function Buttons in Programming 320.8 Going On-Line 320.7 Resetting System to Change Contents of NPM , 320.8 To Return System to Resident System Program 330...
Page 30
SECTION 300 PROGRAMMING 310 Explanation of Programming 1. The Electra-616 Electronic Key Telephone System comes nrovided with a Resident System Program in PROM I 2. Keyset 1 must be installed to allow System Prograrnm- ing. NO other station can program system data. The programming procedure includes the foilowing steps: (Programmable Read Only Memory). When the system is powered this Resident System Program is duplicated in RAM (Random Access Memory) and becomes the Network Plan Memory (NPM)....