NEC Electra 616 General Installation Manual
Here you can view all the pages of manual NEC Electra 616 General Installation Manual. The NEC manuals for Telephone are available online for free. You can easily download all the documents as PDF.
Page 2
c 110 120 130 140 150 160 CONTENTS Page Installation Site Requirements . . . . . . . . . . . . . . . . . . . . . . . 1100-1 110.1 Physical Environment of Equipment Electrical and Grounding Requirements . . . . . . . . . . . . . . . . 100-l 120.1 AC Power Requirements 120.2 Grounding Requirements Other Considerations . . . . . . . . . . . . . . . . . . . . . . . 130.1 Electrical Noise Generators 130.2 Pre-installation Site Survey 130.3 Additional Equipment Specifications . . . . . . ....
Page 3
p SECTION 100 GENERAL INSTALLATION 110 Installation Site Requirements 120.2 Grounding Requirements 110.1 Physical Environment of Equipment The following conditions should be met at the site chosen for mounting the central equipment (Key Service unit>. The KSU must be well-grounded. If a good conduit ground is not present at the dedicated AC outlet, the following steps should be taken: 1. The KSU should normally be wall-mounted to protect against accident or flooding. Where possible use of a...
Page 4
/ 130 Other Consideratiaons 130.1 Electrical Noise Generators Certain equipment, such as welding machines, thyrister-driven power supplies, large electrical motors, etc. generate electrical noise. As a stored program machine the Electra-616 System is vulnerable to this noise. When this type of machine is present at an instahation, the following precautionary steps are urged: 1. Locate KSU, telephone sets, and cabling away from these machines. 2. If cables must pass near these machines, use...
Page 5
I 3. Fuse Replacement Replace fuses in accordance with Table 140- 1. Table 140-l Fuse Specifications For PS-6-1 and KSI-S . . ‘*a Note 1: FI is 1/4”x I-1/4”size normal blown glass tube or ceramic fuse. Buss 3A G 125 V., 4A fuse. Note2: KSI-S Fl - F8 are 13/64” c 45164” (S mm x 20 mm) size normal blown glass tube fuse. Buss GMA I25 V., O.SA fuse. Do not install any ‘slow blow” fuses in the ES-6-I KSU. 140.3 Power Requirements 1. AC Input - 117V AC f 1 O%, SO or 60Hz + 1 O%, single phase ....
Page 6
2. Network 2) Intercom call - Matrix: Single stage, non block- ing C-MOS switch ar- ray Electronic circuit using custom LSI (Equivalent to 500 type standard network) - Calling signal for called station: . Keyset network: - Transmitter and Receiver : Dynamic type (Equivalent to 500 type standard telephone transmitter and receiver) 3. Transmission - Cross talk attenuation: More than 75 dB for - Insertion loss, station to trunk: 300-3, SOOkHz Less than 1.8 dB at IkHZ 140.9 Visual and...
Page 7
.-,_ ,. c) Signal level - Minimum level per frequency: Low group: High group: d) Duration of two frequency signal: e) Interdigital time: 3. Dialing Memories a) Last COjPBX Number Redial: b) Speed Dialing-Station: c) Speed Dialing-System: -1OdBm - 8dBm 60 msec. min. 00 msec. min. 16 digits max. (including pause) 16 numbers (16 digits, including any pauses) 4q numbers (16 digits, including any pauses) 140.11 External Equipment Interfacing 1. External Paging - Output power: 1 watt...
Page 8
6. MFI-S KTU (Dual-Tone Multip Frequency Interface Key Telephone Unit) provides circuits to serve up to 3 CO/PBX lines, and contains circuitry for CO/PBX ring detection, hold and control functions. It also sends DTMF dial signalling to CO/PBX lines in accordance with dialing from keysets. A MFI-S KTY and a DCI-S KTU can be mixed in a system. . 7. 8. 9. 10. 11 KSI-S KTU (Keyset Interface Key Telephone Unit) provides data control to the Electronic Key Telephone set (ET-6-l). Each KSI-S KTU...
Page 9
160 System Configuration 160.1 To Determine Required Equipment 1. Determine how many electronic key telephones are re- quired in the system. Refer to Table A if the number of keysets are 8 or less. Refer to Table B if the number of keysets are more than 8. 2. Determine how many CO/PBX lines are required. The result will tell you which line of the selected table to use. See Table 160-l. Table 160-l Required Quantities of KThls TABLE A: Total Number of Keysets is 1 - 8 TABLE B: Tota! Number of...
Page 10
/--- CQlP0X 123 456 ---_------__ -I I I I 1 I I I I I I I I I I I 1 I 2 SWM 2 i I I I DOOR PHONE 1 DOOR PHONE 2 ---I-l PS-6-! EXT. SPEAKER SECURITY I I CONTROL EQUIPMENT Page 100-8 [ 13 installed in ES&l KSU Fig. 160-l System Block Diagram