5. Maintenance Options and SMDR 5-3 BACKING UP SITE DATA Backing Up Site Data with a PC Card (Figure 5-1) You can use PC Card P/N 85880 to back up and restore your site data. Figure 5-1 USING THE PC CARD To use the PC Card to back up site data: 1. Insert the PC Card into the CPU. 2. Be sure the CPU mode switch is set to RUN . 3. Enter the programming mode. ICM + #*#* + 372000 + HOLD 4. Dial 9906 + HOLD. You see: START? To quit program 9906 instead, dial N + HOLD . 5. Dial Y + HOLD. You see: 9906: DATABASE NAME 6. Enter a name for the database you want to save (up to 10 characters long). Refer to Keys for Entering Nameson the next page if you need help when entering names. Skip this step if you want to save data in an address that already has a name assigned. 80000 - 27 Mode Switch PC Card Active LED
5-4 BACKING UP SITE DATA Figure 5-2 ENTERING NAMES7. When you are done entering the name, press HOLD. You see the name and date of the first database stored. If no data bases are stored, you see: 9906: DB00 (empty) 8. The system assigns the name you entered in step 7 to the data base address you select below: - Press VOLor VOLto scroll through the addresses. In software versions 02.00.01 and higher, there are 16 data base addresses: DB 00 to DB 15. OR - Skip this step to select the currently displayed data base. 9. Press HOLD. Normally, you see 9906: SAVING . . . . . . . . . The PC Card Active LED is on during backup. If the address you choose already has data stored in it, you see: REPLACE DB nn Y/N. - Press N + HOLD to back up to step 5. - Press Y + HOLD to proceed. You automatically exit programming when the upload completes. Keys for Entering Names Press this key: Then one of these keys to enter the character in the white cell:1 2 3 4 # 1& - (dash)1 / (backslash)1 ‘ (apostrophe)1 1 2 ABC 23DEF 34GH I 45JKL 56MNO 67PQRS78TUV 89WX Y Z 90SPACE : 0**# To enter characters in lower case (e.g., e instead of E), press MW before pressing the key in the first shaded column. Use LND to backspace over (erase) any characters you want to correct. 1In software versions prior to 02.00.00, the codes for 1 + 2, 1 + 3, and 1 + 4 were not available.
5. Maintenance Options and SMDR 5-5 BACKING UP SITE DATA PC Card Backup Error Messages This error message . . . Means this . . . NO PCCARD The PC card is not installed. Install the PC card and try again. ERASE FAILED The system could not overwrite an existing data base on the PC card. Repeat the procedure. If you get the message again, try another PC card. SAVE FAILED The system could not save data to the PC card. Repeat the procedure. If you get the message again, try another PC card.
5-6 Restoring Site Data from a PC Card To use the PC Card to restore site data: Review PC Card Data Base Compatibility on page 5-2. 1. Insert the PC Card into the CPU (see Figure 5-1). 2. Be sure the CPU mode switch is set to RUN . 3. Enter the programming mode. ICM + #*#* + 372000 + HOLD 4. Dial 9907 + HOLD. You see: START? 5. Dial Y + HOLD. You see the name and date of the first database stored. If no data bases are stored, you see: 9907: DB00 (empty) 6. Press VOLor VOLto scroll through the data base addresses and select the one you want to restore. In software versions 02.00.01 and higher, there are 16 data base addresses: DB 00 to DB 15.7. When the data base you want to restore displays, press HOLD. The PC Card Active LED is on during restore. You automatically exit programming when the upload completes. PC Card Restore Error Messages This error message . . . Means this . . . NO PCCARD The PC card is not installed. Install the PC card and try again. NO DATABASE There is not data stored in the data base address you selected. Select another data base address and try again. RESTORING SITE DATA
5. Maintenance Options and SMDR 5-7 LOADING NEW SYSTEM SOFTWARE Loading System Software from a PC Card To use the PC Card to load system software (P/N 80051-V**.**.** only): Review PC Card Data Base Compatibility on page 5-2. Loading new system software will automatically reload the factory installed (default) program entries. 1. Insert the PC Card into the CPU (see Figure 5-1). 2. Be sure the CPU mode switch is set to BOOT . 3. Press the reset switch on the CPU to reset the system. The LEDs on the CPU will start to cycle. After about 1 minute, the system will restart with the new software loaded using the factory installed (default) entries. The LEDs on the CPU will then flash normally (see Figure 5-3). 4. Once the system restarts, switch the CPU mode switch to RUN . Major Alarm (Red) On: Major alarm present Off: Major alarm not present ➠ indicates the LEDs normal (i.e., system OK) status.➠ ➠ ➠ Minor Alarm (Red) On: Minor alarm present Off: Minor alarm not present ➠ RS-232 Port (Yellow) Flashing: RS-232 port active Off: RS-232 idle ➠ PC Card (Red) Flashing:PC card write/read active Off: PC card idle 5-3 CPU STATUS LEDSCPU Running (Green) Slow flash: CPU OK On: CPU starting
5-8 SMDR Installing SMDR (Figure 5-4) Station Message Detail Recording (SMDR) provides a record of the system’s outside calls. Once set up in programming, SMDR automatically outputs from the RS-232 (serial) port on the CPU to a customer-provided printer, terminal or SMDR data collection device. When connecting SMDR, you can use one of the ready- made cables or make one of your own (see page 5-12). You can also connect a PC to the CPU serial port to collect call history data.To connect an SMDR device: 1. Plug the DIN end of the 8-Pin DIN to Mod-8 Cable (P/N 80893) into the CPU serial port. 2. Plug one end of the DB9 to Mod-8 Adaptor (P/N 85980) into the cable. 3. Plug the other end of the adaptor into the DB9M COM con- nector on the back of your PC. The Fixed Slot default communications parameters of the CPU serial port are 4800 8 N 1 (4800 baud, eight data bits, no parity and 1 stop bit). The current U Slot default communications parameters of the CPU serial port are 19200 8 N 1 (19200 baud, eight data bits, no parity and 1 stop bit).If you have a PC connected to collect history data, press Shift 1 to turn history on and off. Programming SMDR 0301: CPU Baud Rate Assign the baud rate for the RS-232-C port on the CPU. The options are 2 (1200), 3 (2400), 4 (4800), 5 (9600) and 6 (19200). You can also press Ctrl Break on a PC connected to the CPU serial port to toggle through the available CPU baud rates.0301: SMDR Port Enter 1 to enable SMDR output from the CPU RS-232-C port.0301: Print SMDR Header Enter Y to have the beginning of the SMDR report include the column header data. Enter N to have the SMDR report only include the call data (without the header). 1001: Print SMDR Enter Y to have the SMDR report include calls on the trunk. Enter N to have the SMDR report exclude calls on the trunk.
5. Maintenance Options and SMDR 5-9 Figure 5-4 CONNECTING SMDR 80000 - 49 SMDR DB9M COM PORT CPU RS-232 Port P/N 85980 P/N 80893
5-10 MODEM INSTALLATION Installing a Modem (Figure 5-5) You can connect a modem to the CPU serial port to remotely collect history data and/or SMDR.To connect a modem: 1. Plug the DIN end of the 8-Pin DIN to Mod-8 Cable (P/N 80893) into the CPU serial port. 2. Plug one end of the DB25 to Mod-8 Adaptor (P/N 85981) into the cable. 3. Plug the other end of the adaptor into the DB25F connector on the back of your modem. 4. Following the instructions that came with your modem, con- nect a trunk and the modem’s power supply. To call from a PC at a remote site: The remote PC must have a modem connected. Also, the default communications parameters of the CPU serial port are 4800 8 N 1 (4800 baud, eight data bits, no parity and 1 stop bit). 1. Using commercially available communications software, dial the phone number of the trunk connected to the modem at the telephone system site. 2. To test history, type Shift 1 on the remote PC. If history doesn’t output correctly, press Ctrl Break on the remote PC to toggle through the available CPU baud rates.
5. Maintenance Options and SMDR 5-11 MODEM INSTALLATIONFigure 5-5 INSTALLING A MODEM 80000 - 50 CPU RS-232 Port P/N 80893To trunk Modem Power Supply P/N 85981
5-12 MAKING YOUR OWN DATA CABLES DSR 8-Pin DINMod-8 11RTS 28RXD 35SG 44TXD 56CTS 67DTR P/N 80893 Brown wire (Pin 1) 80000 - 51 5 2 4 8 7 73 DCD 82 1 3 6 8 x 8 JACK WIRING80000-53 1 PIN 1 2 3 4 5 6 7 8BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATECOLOR 8 DB25 WIRING PIN 2 3 4 5 6 7 8 20YELLOW GREEN SLATE BROWN BLUE RED ORANGE BLACKCOLOR14 25 1 13 Mod-8 to 25-Pin Connector for Modem Connection 8 x 8 JACK WIRING80000 - 52 1 PIN 1 2 3 4 5 6 7 8BLUE ORANGE BLACK RED GREEN YELLOW BROWN SLATECOLOR 8 9 6 5 1 DB9 WIRING PIN 1 2 3 4 5 6 7 8JUMPER TO PIN 6 YELLOW GREEN BLUE AND ORANGE RED BLACK JUMPERED TO PIN 1 BROWN SLATECOLORMod-8 to 9-Pin Connector for PC/Laptop Connection Figure 5-6 MAKING YOUR OWN DATA CABLES